Pubfacts - Scientific Publication Data
  • Categories
  • |
  • Journals
  • |
  • Authors
  • Login
  • Categories
  • Journals

Search Our Scientific Publications & Authors

Publications
  • Publications
  • Authors
find publications by category +
Translate page:

Model for deriving the optical performance of the myopic eye corrected with an intracorneal ring.

Authors:
S Patel J Marshall F W Fitzke

J Refract Surg 1995 Jul-Aug;11(4):248-52

Department of Vision Sciences, Glasgow Caledonian University, Scotland.

Background: The intracorneal ring has been advanced as a mechanical device for the correction of myopia. The device may reduce refractive error, but the effect on the overall optical performance of the eye has been neglected. This paper addresses this issue by presenting mathematical models that will predict the effect of the intracorneal ring on refractive error, corneal asphericity, and the spherical aberration of the eye.

Materials And Methods: Algorithms are derived for predicting the corneal apical radius, asphericity, and the change in myopia after inserting intracorneal rings of any thickness and diameter.

Results: The model predicts that the magnitude of myopia reduction is a function of both ring thickness and diameter. The large diameter (9 to 10 mm), thin (0.1 to 0.2 mm) intracorneal ring is less likely to adversely affect corneal asphericity and therefore not significantly enhance the spherical aberration of the eye.

Conclusions: An intracorneal ring cannot correct more than 4.00 diopters (D) of myopia without significantly increasing ocular spherical aberration, which, in turn, will compromise the final visual outcome.

Download full-text PDF

Source
http://dx.doi.org/10.3928/1081-597X-19950701-08DOI Listing
January 1996

Publication Analysis

Top Keywords

intracorneal ring
20
spherical aberration
12
refractive error
8
optical performance
8
corneal asphericity
8
intracorneal
6
ring
6
thickness diameter
4
aberration eyematerials
4
diameter large
4
asphericity spherical
4
error corneal
4
visual outcome
4
methods algorithms
4
ring refractive
4
predict intracorneal
4
will predict
4
large diameter
4
models will
4
diameter thin
4

Keyword Occurance

Similar Publications

Clinical, tomographic, and topometric outcomes of progressive thickness intracorneal ring segment implantations in duck-type keratoconus.

Authors:
Efekan Coskunseven Belma Kayhan

Indian J Ophthalmol 2022 Aug;70(8):2939-2945

Department of Refractive Surgery, Dunyagoz Etiler Hospital; Department of Ophthalmology, Sultan II. Abdulhamid Han Training and Research Hospital, University of Health Sciences, Istanbul, Turkey.

Purpose: To evaluate the visual, refractive, tomographic, and topometric outcomes of progressive thickness intracorneal ring segment (PT-ICRS) implantation in duck-type keratoconus.

Methods: This retrospective study included eyes with oval (duck-type) keratoconus treated with PT-ICRS implantation. After the femtosecond laser tunnel creation, one PT-ICRS (Keraring AS 5 with 160° arc length) was implanted along the ectatic, inferior half of the cornea. Read More

View Article and Full-Text PDF
August 2022
Similar Publications

Intracorneal Ring Segment Implantation Results in Corneal Mechanical Strengthening Visualized With Optical Coherence Elastography.

Authors:
Emilio A Torres-Netto Farhad Hafezi Sabine Kling

J Refract Surg 2022 Jul 1;38(7):459-464. Epub 2022 Jul 1.

Purpose: To quantify the mechanical impact of intracorneal ring segment (ICRS) implantation of different dimensions in an ex vivo eye model.

Methods: A total of 30 enucleated porcine eyes were assigned to ICRS implantation (thickness: 300 µm, angle: 120°, 210°, or 325°), tunnel creation only, or virgin control groups. For mechanical evaluation, each globe was mounted on a customized holder and intraocular pressure (IOP) was increased in steps of 0. Read More

View Article and Full-Text PDF
July 2022
Similar Publications

Effect of intracorneal ring segments on posterior corneal topography in eyes with keratoconus.

Authors:
M M Berty T F Eliwa A A M Gaafar A S Mousa

Arch Soc Esp Oftalmol (Engl Ed) 2022 Aug 22;97(8):424-431. Epub 2022 Jun 22.

Professor of Ophthalmology and Ophthalmic Surgery, Faculty of Medicine, Ain Shams University, Cairo, Egypt.

Purpose: To analyze the changes in the anterior and posterior corneal surfaces measured with a Scheimpflug imaging device in keratoconus patients implanted with intracorneal ring segments (ICRS) and to correlate those changes with the visual outcomes.

Methods: This prospective interventional case series study included 92 eyes of 60 patients with keratoconus who underwent Kerarings (Mediphacos, Belo Horizonte, Brazil) ICRS implantation. Keratometric (K) readings, corneal asphericity (Q value) and elevations of both anterior and posterior corneal surfaces were evaluated using a Scheimpflug imaging device preoperatively and at 1, 3, 6 and 12 months after surgery. Read More

View Article and Full-Text PDF
August 2022
Similar Publications

The Effect of Intracorneal Ring Segments Implantation for Keratoconus on In Vivo Corneal Biomechanics Assessed With the Corvis ST.

Authors:
Riccardo Vinciguerra Luis Fernández-Vega-Cueto Arancha Poo-Lopez Ashkan Eliasy Jesús Merayo-Lloves Ahmed Elsheikh David Madrid-Costa Carlos Lisa José F Alfonso

J Refract Surg 2022 Apr 1;38(4):264-269. Epub 2022 Apr 1.

Purpose: To evaluate the effect of the implantation of intracorneal ring segments (ICRS) in keratoconus on the dynamic corneal response (DCR) parameters obtained with the Corvis ST (Oculus Optikgeräte GmbH).

Methods: This prospective clinical study included patients who underwent ICRS implantation for keratoconus over a period of 1 year. On the day of the surgery and at least 1 month after ICRS implantation, the following measurements were made: corrected and uncorrected distance visual acuity, corneal tomography indices with the Pentacam (Oculus Optikgeräte GmbH), biomechanically corrected intraocular pressure (bIOP), Corvis ST DCR parameters, integrated inverse concave radius (1/R), deformation amplitude ratio (DA ratio), stiffness parameter at first applanation (SP-A1), stress-strain index (SSI), and highest concavity radius (HRC). Read More

View Article and Full-Text PDF
April 2022
Similar Publications

Management of Anterior Stromal Necrosis After Polymethylmethacrylate ICRS: Explantation Versus Exchange With Corneal Allogenic Intrastromal Ring Segments.

Authors:
Karim Kozhaya Carl Joe Mehanna Soosan Jacob Alain Saad Nada S Jabbur Shady T Awwad

J Refract Surg 2022 Apr 1;38(4):256-263. Epub 2022 Apr 1.

Purpose: To evaluate management of keratoconic eyes with anterior stromal necrosis overlying the intracorneal ring segment (ICRS), by either ICRS explantation alone or exchange with corneal allogenic intrastromal ring segments (CAIRS).

Methods: Among 643 Intacs SK (Additional Technology, Inc) inserted at one institutional center, 16 eyes (15 patients) with overlying spontaneous anterior stromal necrosis were identified. Data included size of stromal defect and refractive and topographical findings before ICRS insertion, before anterior stromal necrosis, and 6 months after intervention. Read More

View Article and Full-Text PDF
April 2022
Similar Publications
}
© 2022 PubFacts.
  • About PubFacts
  • Privacy Policy
  • Sitemap