Pubfacts - Scientific Publication Data
  • Categories
  • |
  • Journals
  • |
  • Authors
  • Login
  • Categories
  • Journals

Search Our Scientific Publications & Authors

Publications
  • Publications
  • Authors
find publications by category +
Translate page:

Initial Clinical Experience With a New Conformable Abdominal Aortic Endograft: Aortic Neck Coverage and Curvature Analysis in Challenging Aortic Necks.

Authors:
Alice Finotello Richte Schuurmann Sara Di Gregorio Gian Antonio Boschetti Nabil Chakfé Bianca Pane Giovanni Spinella Jean-Paul de Vries Domenico Palombo Giovanni Pratesi

J Endovasc Ther 2021 Mar 4:1526602821996723. Epub 2021 Mar 4.

Clinic of Vascular and Endovascular Surgery, Ospedale Policlinico San Martino, Department of Integrated Surgical and Diagnostic Sciences, University of Genoa, Italy.

Objectives: Aim of this work was to investigate precision of deployment and conformability of a new generation GORE EXCLUDER Conformable Endoprosthesis with active control system (CEXC Device, W.L. Gore and Associates, Flagstaff, AZ, USA) by analyzing aortic neck coverage and curvature.

Methods: All consecutive elective patients affected by abdominal aortic aneurysm or aortoiliac aneurysm treated at our institution between November 2018 and June 2019 with the new CEXC Device were enrolled. Validated software was adopted to determine the available apposition surface area into the aortic neck, apposition of the endograft to the aortic wall, shortest apposition length (SAL), shortest distance between the endograft fabric and the lowest renal arteries (SFD) and between the endograft fabric and the contralateral renal artery (CFD). Pointwise centerline curvature was also computed.

Results: Twelve patients (10 men, median age 78 years (71.75, 81.0)) with available pre- and postoperative computed tomography angiography (CTA) were included. Technical success was obtained in all the cases. Preoperative median length of the proximal aortic neck was 16.1 mm (10.7, 21.7) and suprarenal (α) and infrarenal (β) neck angulation were, respectively, 28.9° (15.7°, 47.5°) and 75.0° (66.9°, 81.4°). Postoperative median apposition surface coverage was 79% (69.25%, 90.75%) of the available apposition surface. SFD and CFD were 1.5 mm (0.75, 5.25) and 7 mm (4.5, 21.5), respectively. Average curvature over the infrarenal aorta decreased from 25 m (21.75, 29.0) to 22.5 m (18.75, 24.5) postoperatively (p=0.02). Maximum curvature did not decrease significantly from 64.5 m (54.25, 92.0) to 62 m (41.75, 71.5) (p=0.1).

Conclusions: Our early experience showed that deployment of the CEXC Device is safe and effective for patients with challenging proximal aortic necks. Absence of significant changes between pre- and postoperative proximal aortic neck angulations and curvature confirms the high conformability of this endograft.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1526602821996723DOI Listing
March 2021

Publication Analysis

Top Keywords

aortic neck
20
proximal aortic
12
cexc device
12
apposition surface
12
aortic
10
endograft aortic
8
neck coverage
8
abdominal aortic
8
pre- postoperative
8
endograft fabric
8
aortic necks
8
neck
6
curvature
5
apposition
5
endograft
5
cases preoperative
4
preoperative median
4
technical success
4
success cases
4
angiography cta
4

Keyword Occurance

Similar Publications

Morphological applicability of currently available stent grafts in the endovascular repair of asymptomatic abdominal aortic aneurysm in East-Central European patients.

Authors:
Jolanta Tomczak Łukasz Dzieciuchowicz

Postepy Kardiol Interwencyjnej 2021 Mar 27;17(1):93-100. Epub 2021 Mar 27.

Department of Vascular Surgery and Vascular Diseases, Institute of Medical Sciences, University of Zielona Góra, Zielona Góra, Poland.

Introduction: Currently, there is a wide range of commercially available devices for endovascular aneurysm repair (EVAR) that differ in terms of both anatomical requirements and the technology and technique of deployment.

Aim: To assess the applicability of currently commercially available devices for EVAR in the treatment of an asymptomatic abdominal aneurysm (AAA).

Material And Methods: The study group included 100 patients with infrarenal AAA with a maximum diameter ≥ 50 mm, qualified for invasive treatment at the University Hospital in 2013-2014. Read More

View Article and Full-Text PDF
March 2021
Similar Publications

F-fluorodeoxyglucose positron emission tomography/computed tomography of giant cell arteritis with lower extremity involvement in association with polymyalgia rheumatica.

Authors:
Ananya Panda Gregory A Wiseman Matthew J Koster Kenneth J Warrington Geoffrey B Johnson

World J Nucl Med 2021 Jan-Mar;20(1):90-92. Epub 2020 Oct 2.

Department of Radiology, Mayo Clinic, Rochester, MN, USA.

An 80-year-old man presented with new-onset pain in the shoulders and lower extremities and elevated serum inflammatory markers. A clinical diagnosis of polymyalgia rheumatica (PMR) was made, but there was a suboptimal response to glucocorticoid therapy, prompting further evaluation. F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) revealed intense FDG uptake in the arteries of the bilateral lower extremities, head, and neck, but sparing the aorta, suggestive of an uncommon pattern of giant cell arteritis (GCA). Read More

View Article and Full-Text PDF
October 2020
Similar Publications

Effects of Myo-inositol Hexaphosphate (SNF472) on Bone Mineral Density in Patients Receiving Hemodialysis: An Analysis of the Randomized, Placebo-Controlled CaLIPSO Study.

Authors:
David A Bushinsky Paolo Raggi Jordi Bover Markus Ketteler Antonio Bellasi Mariano Rodriguez Smeeta Sinha Rekha Garg Joan Perelló Alex Gold Glenn M Chertow

Clin J Am Soc Nephrol 2021 Apr 7. Epub 2021 Apr 7.

Department of Medicine, Stanford University, Palo Alto, California.

Background And Objectives: In the CaLIPSO study, intravenous administration of SNF472 (300 or 600 mg) during hemodialysis significantly attenuated progression of coronary artery and aortic valve calcification. SNF472 selectively inhibits formation of hydroxyapatite, the final step in cardiovascular calcification. Because bone mineral is predominantly hydroxyapatite, we assessed changes in bone mineral density in CaLIPSO. Read More

View Article and Full-Text PDF
April 2021
Similar Publications

Favorable Outcomes in Octogenarians with Hostile Neck undergoing Endovascular Repair using EndoAnchors.

Authors:
Satinderjit Locham Asma Mathlouthi Hanaa Dakour-Aridi Mahmoud B Malas

Ann Vasc Surg 2021 Apr 3. Epub 2021 Apr 3.

University of California San Diego, La Jolla, California.

Objectives: Standard endovascular repair (EVAR) is not suitable in patients with hostile aortic anatomy. Open aneurysm repair (OAR) has been the gold-standard approach in managing these patients. EndoAnchors have been introduced as a technique to make EVAR in patients with short and angulated necks possible. Read More

View Article and Full-Text PDF
April 2021
Similar Publications

A Rare Cause of Ortner's Syndrome and a Case-Based Review of Literature.

Authors:
Sukanya Madhuraj Harikrishnan Gangadharan Remya Manju Akhil Prakash Saravana S Arasan Sajitha Krishnadas Satish Kumar

Indian J Otolaryngol Head Neck Surg 2021 Apr 1:1-4. Epub 2021 Apr 1.

Department of General Medicine, Government Medical College, Kottayam, Kerala, India.

Ortner's syndrome refers to the compression of the recurrent laryngeal nerve by cardiovascular disorders of various etiologies. We describe a rare case of Ortner's syndrome caused by thoracic aorta aneurysm and a brief review of literature on this unusual cause of Ortner's syndrome. Hoarseness of voice due to the compression of recurrent laryngeal nerve by thoracic aorta aneurysm could be a harbinger of aneurysmal rupture. Read More

View Article and Full-Text PDF
April 2021
Similar Publications
© 2021 PubFacts.
  • About PubFacts
  • Privacy Policy
  • Sitemap