Comparison of clinical outcomes and accuracy of electrode placement between robot-assisted and conventional deep brain stimulation of the subthalamic nucleus: a single-center study.

Authors:
Shams Ribault Emile Simon Julien Berthiller Gustavo Polo Adélaïde Nunes Andrei Brinzeu Patrick Mertens Teodor Danaila Stéphane Thobois Chloé Laurencin

Acta Neurochir (Wien) 2021 Mar 2. Epub 2021 Mar 2.

Service de Neurologie C, Centre Expert Parkinson, Hôpital Neurologique et Neurochirurgical Pierre Wertheimer, Hospices Civils de Lyon, 69003, Lyon, France.

Background: Several surgical methods are used for deep brain stimulation (DBS) of the subthalamic nucleus (STN) in Parkinson's disease (PD). This study aimed to compare clinical outcomes and electrode placement accuracy after robot-assisted (RAS) versus frame-based stereotactic (FSS) STN DBS in Parkinson's disease.

Methods: In this single-center open-label study, we prospectively collected data from 48 consecutive PD patients who underwent RAS (Neuromate®; n = 20) or FSS (n = 28) STN DBS with the same MRI-based STN targeting between October 2016 and December 2018 in the university neurological hospital of Lyon, France. Clinical variables were assessed before and 1 year after surgery. The number of electrode contacts within the STN was determined by merging post-operative CT and pre-operative MRI using Brainlab® GUIDE™XT software.

Results: One year after surgery, the improvement of motor manifestations (p = 0.18), motor complications (p = 0.80), and quality of life (p= 0.30) and the reduction of dopaminergic treatment (p = 0.94) and the rate of complications (p = 0.99) were similar in the two groups. Surgery duration was longer in the RAS group (p = 0.0001). There was no difference in the number of electrode contacts within the STN.

Conclusion: This study demonstrates that RAS and FSS STN DBS for PD provide similar clinical outcomes and accuracy of electrode placement.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00701-021-04790-7DOI Listing
March 2021

Publication Analysis

Top Keywords

electrode placement
12
fss stn
12
clinical outcomes
12
stn dbs
12
electrode contacts
8
subthalamic nucleus
8
year surgery
8
deep brain
8
brain stimulation
8
number electrode
8
outcomes accuracy
8
accuracy electrode
8
stn
6
electrode
5
neuromate® fss
4
mri-based stn
4
dbs mri-based
4
080 quality
4
motor manifestations
4
groups surgery
4

Keyword Occurance

Similar Publications

A comparison of insertion methods for surgical placement of penetrating neural interfaces.

Authors:
Brianna Thielen Ellis Meng

J Neural Eng 2021 Apr 12. Epub 2021 Apr 12.

Department of Biomedical Engineering, University of Southern California, University Park, 3650 S McClintock Avenue, Los Angeles, California, 90089, UNITED STATES.

Many implantable electrode arrays exist for the purpose of stimulating or recording electrical activity in brain, spinal, or peripheral nerve tissue, however most of these devices are constructed from materials that are mechanically rigid. A growing body of evidence suggests that the chronic presence of these rigid probes in the neural tissue causes a significant immune response and glial encapsulation of the probes, which in turn leads to gradual increase in distance between the electrodes and surrounding neurons. In recording electrodes, the consequence is the loss of signal quality and, therefore, the inability to collect electrophysiological recordings long term. Read More

View Article and Full-Text PDF
April 2021
Similar Publications

A novel local field potential-based functional approach for targeting the centromedian-parafascicular complex for deep brain stimulation.

Authors:
Jackson N Cagle Robert S Eisinger Marshall T Holland Kelly D Foote Michael S Okun Aysegul Gunduz

Neuroimage Clin 2021 Mar 26;30:102644. Epub 2021 Mar 26.

J. Crayton Pruitt Department of Biomedical Engineering, University of Florida, Gainesville FL, United States.

Background: The centromedian-parafascicular (Cm-Pf) complex of the thalamus is a common deep brain stimulation (DBS) target for treatment of Tourette syndrome (TS). Currently, there are no standardized functional intraoperative neurosurgical targeting approaches. Collectively, these issues have led to variability in DBS lead placement. Read More

View Article and Full-Text PDF
March 2021
Similar Publications

Method to Reduce the Contact Resistivity between Galinstan and a Copper Electrode for Electrical Connection in Flexible Devices.

Authors:
Takashi Sato Kento Yamagishi Michinao Hashimoto Eiji Iwase

ACS Appl Mater Interfaces 2021 Apr 8. Epub 2021 Apr 8.

Department of Material Science, Waseda University, 3-4-1 Okubo, Shinjuku-ku, Tokyo 169-8555, Japan.

This study demonstrates a method to mount electronic components using gallium-based liquid metals (LMs) with reduced contact resistivity between the LM and a copper (Cu) electrode. Gallium-based LMs have low volume resistivity and low melting points, and they are used as electronic components such as interconnects and sensors of stretchable electronic devices. However, the high contact resistivity of the oxide layer on the surface of the Ga-based LMs becomes a problem when the Ga-based LMs are used in contact with rigid electronic components. Read More

View Article and Full-Text PDF
April 2021
Similar Publications

Structural Heart Issues in Dextrocardia: Situs Type Matters.

Authors:
Charles J Fox Yenabi Keflemariam Elyse M Cornett Richard D Urman Yury Rapoport Bipin Shah Mary C Mancini Alan D Kaye

Ochsner J 2021 ;21(1):111-114

Department of Anesthesiology, Louisiana State University Health-Shreveport, Shreveport, LA.

Patients who are diagnosed with dextrocardia, a rare congenital heart condition in which the heart points toward the right side of the chest, need their specific situs classification (eg, solitus, inversus, ambiguus) ascertained to optimize their care and outcomes. In this report, we discuss the perioperative anesthetic management of a patient presenting with dextrocardia. A 44-year-old African American female with a history of hypertension, hyperlipidemia, gastroesophageal reflux disease, and diabetes mellitus type 2 was admitted for shortness of breath, dyspnea on exertion, orthopnea, and paroxysmal nocturnal dyspnea. Read More

View Article and Full-Text PDF
January 2021
Similar Publications

Sensitivity, Specificity and Accuracy of a Novel EEG-Based Objective Test, the Cognalyzer, in Detecting Cannabis Psychoactive Effects.

Authors:
Alison C McDonald Israel Gasperin Haaz Weikai Qi David C Crowley Najla Guthrie Malkanthi Evans Dan Bosnyak

Adv Ther 2021 Apr 7. Epub 2021 Apr 7.

Zentrela Inc., Suite B21, 175 Longwood Rd S, Hamilton, ON, L8P 0A1, Canada.

Introduction: Current standards for identifying recent cannabis use are based on body fluid testing. The Cognalyzer is a novel electroencephalography (EEG) measurement device and algorithm designed to objectively characterize brainwave alterations associated with cannabis. The objective of this study was to assess the accuracy, sensitivity and specificity levels of the Cognalyzer to characterize brainwave alterations following cannabis inhalation. Read More

View Article and Full-Text PDF
April 2021
Similar Publications
© 2021 PubFacts.
  • About PubFacts
  • Privacy Policy
  • Sitemap