Pubfacts - Scientific Publication Data
  • Categories
  • Journals
  • ->
  • Login
  • Categories
  • Journals

Search Our Scientific Publications & Authors

Publications
  • Publications
  • Authors
find publications by category +
Translate page:
Get 20% Off Journals at LWW.com

High shear stress amplitude in combination with prolonged stimulus duration determine induction of osteoclast formation by hematopoietic progenitor cells.

Authors:
Cornelia Bratengeier Aneta Liszka Johan Hoffman Astrid D Bakker Anna Fahlgren

FASEB J 2020 03 19;34(3):3755-3772. Epub 2020 Jan 19.

Department of Clinical and Experimental Medicine, Division of Cell Biology, Linköping University, Linköping, Sweden.

To date, it is unclear how fluid dynamics stimulate mechanosensory cells to induce an osteoprotective or osteodestructive response. We investigated how murine hematopoietic progenitor cells respond to 2 minutes of dynamic fluid flow stimulation with a precisely controlled sequence of fluid shear stresses. The response was quantified by measuring extracellular adenosine triphosphate (ATP), immunocytochemistry of Piezo1, and sarcoplasmic/endoplasmic Ca reticulum ATPase 2 (SERCA2), and by the ability of soluble factors produced by mechanically stimulated cells to modulate osteoclast differentiation. We rejected our initial hypothesis that peak wall shear stress rate determines the response of hematopoietic progenitor cells to dynamic fluid shear stress, as it had only a minor correlation with the abovementioned parameters. Low stimulus amplitudes corresponded to activation of Piezo1, SERCA2, low concentrations of extracellular ATP, and inhibition of osteoclastogenesis and resorption area, while high amplitudes generally corresponded to osteodestructive responses. At a given amplitude (3 Pa) and waveform (square), the duration of individual stimuli (duty cycle) showed a strong correlation with the release of ATP and osteoclast number and resorption area. Collectively, our data suggest that hematopoietic progenitor cells respond in a viscoelastic manner to loading, since a combination of high shear stress amplitude and prolonged duty cycle is needed to trigger an osteodestructive response. PLAIN LANGUAGE SUMMARY: In case of painful joints or missing teeth, the current intervention is to replace them with an implant to keep a high-quality lifestyle. When exercising or chewing, the cells in the bone around the implant experience mechanical loading. This loading generally supports bone formation to strengthen the bone and prevent breaking, but can also stimulate bone loss when the mechanical loading becomes too high around orthopedic and dental implants. We still do not fully understand how cells in the bone can distinguish between mechanical loading that strengthens or weakens the bone. We cultured cells derived from the bone marrow in the laboratory to test whether the bone loss response depends on (i) how fast a mechanical load is applied (rate), (ii) how intense the mechanical load is (amplitude), or (iii) how long each individual loading stimulus is applied (duration). We mimicked mechanical loading as it occurs in the body, by applying very precisely controlled flow of fluid over the cells. We found that a mechanosensitive receptor Piezo1 was activated by a low amplitude stimulus, which usually strengthens the bone. The potential inhibitor of Piezo1, namely SERCA2, was only activated by a low amplitude stimulus. This happened regardless of the rate of application. At a constant high amplitude, a longer duration of the stimulus enhanced the bone-weakening response. Based on these results we deduce that a high loading amplitude tends to be bone weakening, and the longer this high amplitude persists, the worse it is for the bone.

Download full-text PDF

Source
http://dx.doi.org/10.1096/fj.201901458RDOI Listing
March 2020

Publication Analysis

Top Keywords

shear stress
16
progenitor cells
16
mechanical loading
16
hematopoietic progenitor
16
bone
11
cells
10
amplitude
9
dynamic fluid
8
duty cycle
8
amplitude stimulus
8
piezo1 serca2
8
high amplitude
8
precisely controlled
8
osteodestructive response
8
activated low
8
cells bone
8
low amplitude
8
stress amplitude
8
fluid shear
8
high shear
8

Similar Publications

Device-induced Platelet Dysfunction in Patients after Left Ventricular Assist Device Implantation.

Authors:
Kristin Klaeske Maja-Theresa Dieterlen Sandra Eifert Ute Scholz Jens Garbade Khalil Jawad Franz Sieg Michael A Borger Anna L Meyer

J Thromb Haemost 2021 Feb 26. Epub 2021 Feb 26.

Department of Cardiac Surgery, University Hospital Heidelberg, Heidelberg, Germany.

Background: Non-surgical bleeding (NSB) is a major complication after left ventricular assist device (LVADs) implantation. It has been reported that non-physiological shear stress caused by LVADs could altered platelet receptor expression, which leads to bleeding disorders caused by coagulation dysfunctions.

Objectives: Because bleeding diathesis could be multifactorial, we focused on the combined characterization of platelet receptor expression patterns and oxidative stress to compare patients with NSB and patients without coagulation disorder in a monocentric, prospective study. Read More

View Article and Full-Text PDF
February 2021
Similar Publications

Hydrogel-Supported, Engineered Model of Vocal Fold Epithelium.

Authors:
Anitha Ravikrishnan Eric W Fowler Alexander J Stuffer Xinqiao Jia

ACS Biomater Sci Eng 2021 Feb 26. Epub 2021 Feb 26.

Department of Materials Science and Engineering, University of Delaware, Newark, Delaware 19716, United States.

There is a critical need for the establishment of an engineered model of the vocal fold epithelium that can be used to gain understanding of its role in vocal fold health, disease, and facilitate the development of new treatment options. Toward this goal, we isolated primary vocal fold epithelial cells (VFECs) from healthy porcine larynxes and used them within passage 3. Culture-expanded VFECs expressed the suprabasal epithelial marker cytokeratin 13 and intercellular junctional proteins occludin, E-cadherin, and zonula occludens-1. Read More

View Article and Full-Text PDF
February 2021
Similar Publications

A mesoscale finite element modeling approach for understanding brain morphology and material heterogeneity effects in chronic traumatic encephalopathy.

Authors:
A Bakhtiarydavijani G Khalid M A Murphy K L Johnson L E Peterson M Jones M F Horstemeyer A C Dobbins R K Prabhu

Comput Methods Biomech Biomed Engin 2021 Feb 26:1-15. Epub 2021 Feb 26.

Center for Advanced Vehicular Systems, Mississippi State University, Starkville, MS, USA.

Chronic Traumatic Encephalopathy (CTE) affects a significant portion of athletes in contact sports but is difficult to quantify using clinical examinations and modeling approaches. We use an approach to quantify CTE biomechanics using mesoscale Finite Element (FE) analysis that bridges with macroscale whole head FE analysis. The sulci geometry produces complex stress waves that interact with one another to create increased shear stresses at the sulci depth that are significantly larger than in analyses without sulci (from 0. Read More

View Article and Full-Text PDF
February 2021
Similar Publications

Patient-Specific Computational Analysis of Hemodynamics and Wall Mechanics and Their Interactions in Pulmonary Arterial Hypertension.

Authors:
Byron A Zambrano Nathan McLean Xiaodan Zhao Ju-Le Tan Liang Zhong C Alberto Figueroa Lik Chuan Lee Seungik Baek

Front Bioeng Biotechnol 2020 28;8:611149. Epub 2021 Jan 28.

Department of Mechanical Engineering, Michigan State University, East Lansing, MI, United States.

Vascular wall stiffness and hemodynamic parameters are potential biomechanical markers for detecting pulmonary arterial hypertension (PAH). Previous computational analyses, however, have not considered the interaction between blood flow and wall deformation. Here, we applied an established computational framework that utilizes patient-specific measurements of hemodynamics and wall deformation to analyze the coupled fluid-vessel wall interaction in the proximal pulmonary arteries (PA) of six PAH patients and five control subjects. Read More

View Article and Full-Text PDF
January 2021
Similar Publications

Primary Cilia and Atherosclerosis.

Authors:
Zhi-Mei Wang Xiao-Fei Gao Jun-Jie Zhang Shao-Liang Chen

Front Physiol 2021 2;12:640774. Epub 2021 Feb 2.

Department of Cardiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, China.

In artery tree, endothelial function correlates with the distribution of shear stress, a dragging force generated by flowing blood. In laminar shear stress areas, endothelial cells (ECs) are available to prevent atherosclerosis, however, ECs in disturbed shear stress sites are featured with proinflammation and atherogenesis. Basic studies in the shear stress field that focused on the mechanosensors of ECs have attracted the interest of researchers. Read More

View Article and Full-Text PDF
February 2021
Similar Publications
Get 20% Off Journals at LWW.com
© 2021 PubFacts.
  • About PubFacts
  • Privacy Policy
  • Sitemap