Mass energy absorption coefficients and energy responses of magnesium tetraborate dosimeters for 0.02 MeV to 20 MeV photons using Monte Carlo simulations.

Authors:
Luiza F Souza
Luiza F Souza
a Laboratory of Environmental Sanitation
Divanizia N Souza
Divanizia N Souza
Depto. de Educação
Aveiro | Portugal

Appl Radiat Isot 2019 Jun 13;148:232-239. Epub 2019 Apr 13.

Departamento de Física, Universidade Federal de Sergipe (UFS), São Cristóvão, SE, Brazil. Electronic address:

Thermoluminescence dosimeters containing boron, such as magnesium tetraborate (MgBO), are of interest because of their very high sensitivity, near tissue-equivalent absorption coefficients, low cost, easy handling, and very large linearity range for absorbed dose. Another important parameter that should be considered when working with thermoluminescent dosimeter (TLD) is the mass energy absorption coefficient (μ/ρ), which is a close approximation to the energy available for production of chemical, biological and other effects associated with exposure to ionizing radiation, therefore important in estimating dose in medical and health physics. In this study the mass energy absorption coefficients and energy responses of undoped and some doped magnesium tetraborates were calculated by Monte Carlo N-particle transport code for a range of photon energies between 20 keV and 20 MeV. The calculated parameters for MgBO, MgBO:Dy and MgBO:Dy,Li were evaluated in comparison with standard TLDs as AlO:C and TLD-100 (LiF: Mg, Ti) and ICRU tissue data. The influence of the dopant concentration in the MgBO matrix on the energy dependence of TLD was also investigated. The analyses indicated a good agreement between the simulations and theoretical calculations. The μ/ρ and energy dependence of the materials are higher in the low energy range (E < 100 keV), which is related to the high probability of interaction between radiation and matter due to photoelectric absorption. With regard to the influence of dysprosium concentration in the MgBO matrix an increase in the energy dependence of MgBO for higher concentrations of dopants was observed in the low energy range.

Download full-text PDF

Source
https://linkinghub.elsevier.com/retrieve/pii/S09698043183071
Publisher Site
http://dx.doi.org/10.1016/j.apradiso.2019.04.015DOI Listing
June 2019
3 Reads

Publication Analysis

Top Keywords

energy absorption
12
absorption coefficients
12
mass energy
12
magnesium tetraborate
8
energy dependence
8
energy responses
8
coefficients energy
8
monte carlo
8
energy
8
tld investigated
4
dependence tld
4
tld-100 lif
4
chemical biological
4
effects associated
4
biological effects
4
matrix energy
4
radiation estimating
4
estimating dose
4
ionizing radiation
4
production chemical
4

Similar Publications