Smaller-Diameter Covered Transjugular Intrahepatic Portosystemic Shunt Stents Are Associated With Increased Survival.

Clin Gastroenterol Hepatol 2019 Mar 30. Epub 2019 Mar 30.

Department of Gastroenterology, University Hospital Freiburg, Freiburg, Germany.

Background & Aims: We studied the effects of diameter of covered, self-expandable, nitinol stents on survival times of patients with a transjugular intrahepatic portosystemic shunt (TIPS).

Methods: We collected data from 185 patients (median age, 55 y; 30% female) who received a covered nitinol stent, from February 2006 through September 2010, using the online multicenter German TIPS registry. TIPS were given to 107 patients for refractory ascites and to 78 patients for variceal bleeding. Patients at risk of hepatic encephalopathy (owing to advanced age, prior episodes) or liver failure (bilirubin level, >3 mg/dL), and bleeding patients receiving variceal embolization at TIPS, received 8-mm stents (n = 53). The remaining patients received 10-mm stents (n = 132). Eighty-one of the 10-mm stents were underdilated using 8-mm dilation balloons. Clinical and biochemical data were collected after TIPS placement at 1 month, 3 months, 6 months, 9 months, 1 year, and thereafter every 3 to 6 months. Groups were compared using propensity score analysis.

Results: Patients who received 8-mm stents survived significantly longer (34 ± 26 mo) than patients who received 10-mm stents (18 ± 19 mo), regardless of whether they were fully dilated or underdilated. When we compared 10-mm stents with or without underdilation, we found that a significantly higher proportion of patients who received underdilated stents survived for 1 month after TIPS placement (95% vs 84%; P = .03), but not for 3 months (P = .10). In multivariate analysis, 1-year mortality correlated with full dilation of the stent to 10 mm (hazard ratio [HR], 2.0; 95% CI, 1.1-3.5) and with serum creatinine concentration at baseline (HR, 1.5; 95% CI, 1.0-1.7). Five-year mortality was associated with use of the 8-mm stents (HR, 1.8; 95% CI, 1.4-2.7) and baseline concentration of creatinine (HR, 1.3; 95% CI, 1.1-1.6).

Conclusions: A smaller stent (nominal diameter of 8 mm, but not underdilation of a 10-mm stent) is associated with a prolonged survival compared with 10-mm stents, independent of liver-specific prognostic criteria.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cgh.2019.03.042DOI Listing

Still can't find the full text of the article?

We can help you send a request to the authors directly.
March 2019
5 Reads

Article Mentions


Provided by Crossref Event Data
twitter
Twitter:
April 2, 2019, 7:29 am EST
twitter
Twitter:
April 2, 2019, 7:23 am EST
twitter
Twitter:
April 2, 2019, 7:10 am EST

Publication Analysis

Top Keywords

10-mm stents
20
patients received
16
8-mm stents
12
stents
11
patients
10
stents n =
8
compared 10-mm
8
stents survived
8
tips placement
8
months months
8
received 10-mm
8
bleeding patients
8
received 8-mm
8
portosystemic shunt
8
transjugular intrahepatic
8
intrahepatic portosystemic
8
10-mm
6
received
6
tips
5
95%
5

Similar Publications