Performance of ultrasound for detection of transjugular intrahepatic portosystemic shunt dysfunction: a meta-analysis.

Authors:
Hrishikesh Samant
Hrishikesh Samant
Louisiana State University Health Science Center
Transplant Hepatology
shreveport, LA | United States

Abdom Radiol (NY) 2019 07;44(7):2392-2402

Department of Family Medicine and Preventive Medicine, Prince of Songkhla University, Songkhla, Thailand.

Purpose: Although ultrasound has been widely used to evaluate transjugular intrahepatic portosystemic shunts (TIPS) patency, several studies have reported conflicting data regarding its performance. Therefore, we aimed to evaluate performance of ultrasound for detection of TIPS dysfunction by performing a meta-analysis.

Methods: Literature search was performed for studies evaluating ultrasound for TIPS dysfunction, stenosis, and occlusion using PubMed, EMBASE, Scopus, and Cochrane Library through February 2019. Pooled sensitivity, specificity, log diagnostic odds ratio (LDOR), and area under curve (AUC) of summary receiver-operating characteristic were calculated. Subgroup analyses were performed according to ultrasonographic criteria and type of stent.

Results: In total, 21 studies were evaluated. Pooled sensitivity, specificity, and LDOR of ultrasound for detection of TIPS dysfunction were 0.82 (0.67, 0.93), 0.58 (0.46, 0.70), and 1.77 (1.20, 2.35). Pooled sensitivity, specificity, and LDOR for TIPS stenosis were 0.80 (0.69, 0.90), 0.80 (0.69, 0.91), and 2.83 (1.88, 3.78). Pooled sensitivity, specificity, and LDOR for TIPS occlusion were 0.96 (0.92, 0.99), 1 (0.99, 1.00), and 6.28 (4.96, 7.60). AUCs of ultrasound for TIPS dysfunction, stenosis, and occlusion were 0.77, 0.86, and 0.95, respectively.

Conclusions: Although ultrasound had excellent performance for TIPS occlusion and acceptable performance for TIP stenosis, most studies utilized bare metal stent, and therefore, application to current practice is limited. Ultrasound for TIPS dysfunction in the setting of covered metal stent appeared to have acceptable sensitivity of 0.82, but limited specificity of 0.58 and low LDOR of 1.77. A new noninvasive tool is needed for detection of TIPS dysfunction in the era of covered metal stent.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00261-019-01981-wDOI Listing
July 2019
7 Reads

Publication Analysis

Top Keywords

tips dysfunction
20
pooled sensitivity
16
sensitivity specificity
16
metal stent
12
detection tips
12
ultrasound detection
12
ultrasound tips
12
specificity ldor
12
tips
10
ldor tips
8
covered metal
8
tips occlusion
8
stenosis occlusion
8
intrahepatic portosystemic
8
080 069
8
transjugular intrahepatic
8
dysfunction stenosis
8
performance ultrasound
8
ultrasound
7
dysfunction
6

References

(Supplied by CrossRef)

MC Foshager et al.
AJR Am J Roentgenol 1995

C Bureau et al.
Liver International 2007

M Cura et al.
American Journal of Roentgenology 2008

JG Abraldes et al.
Am J Gastroenterol 2005

A Benito et al.
Abdom Imaging 2004

VA Feldstein et al.
Radiology 1996

CA Owens et al.
Gastroenterology 1998

D Moher et al.
PLoS Med 2009

Similar Publications