Quality in urine microscopy: The eyes of the beholder.

Authors:
James F Simon
James F Simon
Cleveland Clinic
United States

Cleve Clin J Med 2018 01;85(1):22-24

Transplant Nephrology Fellow, Department of Nephrology and Hypertension, Cleveland Clinic, Cleveland, OH, USA.

Download full-text PDF

Source
http://dx.doi.org/10.3949/ccjm.85a.17085DOI Listing
January 2018
3 Reads

Publication Analysis

Top Keywords

eyes beholder
4
microscopy eyes
4
urine microscopy
4
quality urine
4
beholder
1
microscopy
1
eyes
1
quality
1

Similar Publications

Urine sediment examination: a comparison of automated urinalysis systems and manual microscopy.

Clin Chim Acta 2007 Sep 26;384(1-2):28-34. Epub 2007 May 26.

Department of Laboratory Medicine, National Taiwan University Hospital, Taiwan.

Background: Several automated instruments examining urine sediment have been introduced. We compared the performance of Sysmex UF-100 and Iris iQ200 with manual microscopy in urine sediment testing.

Methods: Four hundred and thirty-six urine samples were collected. Read More

View Article
September 2007

Correlation between dipstick urinalysis and urine sediment microscopy in detecting haematuria among children with sickle cell anaemia in steady state in Ilorin, Nigeria.

Pan Afr Med J 2013 15;15:135. Epub 2013 Aug 15.

Department of Paediatrics, Federal Medical Centre, Makurdi, Benue State, Nigeria.

Introduction: Haematuria is one of the clinical manifestations of sickle cell nephropathy. Although dipstick urinalysis detects haemoglobin and by extension haematuria; it does not confirm haematuria. Urine sediment microscopy confirms haematuria and constitutes a non-invasive "renal biopsy". Read More

View Article
July 2014

Urine collection pads: are samples reliable for urine biochemistry and microscopy?

Pediatr Nephrol 2005 Feb 28;20(2):170-9. Epub 2004 Dec 28.

Department of Child Health, Rotherham General Hospital, Rotherham S60 2UD, UK.

The aim of the study was to validate the reliability of samples obtained with urine collection pads (UCP) for selected laboratory biochemical analyses, urine cell microscopy, and bedside semi-quantitative stick urinalysis. A series of laboratory experiments was performed to test agreement between urine concentrations, or results, before and after passage through a UCP (incubated for 37 degrees C for 15 min). The following urinalyses were performed: electrolytes, calcium, phosphate, urate, osmolality, pH, protein, catecholamines, toxicology for drugs of abuse, stick urinalysis for glucose, ketones, protein, blood, leucocytes and nitrites, and microscopy for red and white cells. Read More

View Article
February 2005

Dipstick screening for urinary tract infection in febrile infants.

Pediatrics 2014 May;133(5):e1121-7

Department of Pediatrics and Research Enterprise, University of Utah, Salt Lake City, Utah; and.

Objective: This study compares the performance of urine dipstick alone with urine microscopy and with both tests combined as a screen for urinary tract infection (UTI) in febrile infants aged 1 to 90 days.

Methods: We queried the Intermountain Healthcare data warehouse to identify febrile infants with urine dipstick, microscopy, and culture performed between 2004 and 2011. UTI was defined as >50‚ÄČ000 colony-forming units per milliliter of a urinary pathogen. Read More

View Article
May 2014