BEHAVIOR OF POST-INSTALLED ANCHORS TESTED BY STEPWISE INCREASING CYCLIC LOAD PROTOCOLS.

Authors:
Philipp Mahrenholtz Rolf Eligehausen Tara C Hutchinson Matthew S Hoehler

ACI Struct J 2016 Sep;113(5):997-1008

Cyclic loads are a characteristic feature of actions acting on structures and anchorages during earthquakes. For this reason, seismic qualification of post-installed concrete anchors according to the internationally recognized American Concrete Institute (ACI) standard ACI 355 is based on cyclic load tests. The protocols for these tests, however, have limited scientific basis. Therefore, in the present paper newly-developed test protocols with stepwise-increasing load amplitudes are utilized to more realistically evaluate anchor seismic performance. The study focuses on the load-displacement behavior of common anchor types installed in cracked concrete and subjected to both cyclic tension and cyclic shear actions. The results confirmed robust behavior for anchors loaded in cyclic tension even in the presence of crack widths in the anchorage material larger than currently required by ACI 355. In addition, the critical influence of low cycle fatigue on the performance of anchors loaded in cyclic shear is demonstrated.

Download full-text PDF

Source
http://dx.doi.org/10.14359/51689023DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5120405PMC
September 2016

Publication Analysis

Top Keywords

loaded cyclic
8
aci 355
8
cyclic tension
8
anchors loaded
8
cyclic shear
8
cyclic load
8
cyclic
7
shear demonstrated
4
seismic performance
4
performance study
4
focuses load-displacement
4
study focuses
4
evaluate anchor
4
load-displacement behavior
4
behavior common
4
common anchor
4
anchor seismic
4
amplitudes utilized
4
realistically evaluate
4
utilized realistically
4

Keyword Occurance

Similar Publications

All-Suture Anchor Repair of the Flexor Digitorum Profundus Insertion: A Biomechanical Comparison of 2 Suturing Techniques.

Authors:
Christopher M Belyea Pooyan Abbasi Kavya K Sanghavi Aviram M Giladi Kenneth R Means

J Hand Surg Am 2022 Jun 28. Epub 2022 Jun 28.

The Curtis National Hand Center, MedStar Union Memorial Hospital, Baltimore, MD. Electronic address:

Purpose: We compared 2 suturing techniques for reattachment of the flexor digitorum profundus (FDP) via all-suture anchor.

Methods: We used fresh, matched-pair, cadaveric hands. We disarticulated the fingers at the proximal interphalangeal joints, preserving the proximal FDP. Read More

View Article and Full-Text PDF
June 2022
Similar Publications

Biomechanical Comparison of Three Suspensory Techniques for all Soft Tissue Central Quadriceps Tendon Graft Fixation.

Authors:
Michelle E Arakgi Timothy A Burkhart Takashi Hoshino Ryan Degen Alan Getgood

Arthrosc Sports Med Rehabil 2022 Jun 26;4(3):e843-e851. Epub 2022 Mar 26.

Fowler Kennedy Sports Medicine Clinic, Western University, London, Ontario, Canada.

Purpose: The purpose of this study was to evaluate three different methods of attachment of continuous loop suspensory cortical preparation of all soft tissue central quad tendon grafts compared to a bone block control for anterior cruciate ligament reconstruction on construct displacement and load to failure.

Methods: Thirty-two cadaveric central quadriceps tendon (CQT) specimens were harvested, using three clinical techniques for graft fixation: cortical button alone (BTB EB), BTB cortical button with rip-stop suture (BTB RS), and continuous loop cortical button (BTB CL). A control group was also included that consisted of a bone block secured within testing clamps (BTB CON). Read More

View Article and Full-Text PDF
June 2022
Similar Publications

Anterior Cruciate Ligament Reconstruction with 4-Strand Hamstring Tendon Construct May be Biomechanically Superior to 5-Strand Hamstring Tendon Construct When Using Femoral Suspensory Fixation.

Authors:
Mia S Hagen Woody Sorey Ermyas Kahsai Scott Telfer Kenneth Chin Christopher Y Kweon Albert O Gee

Arthrosc Sports Med Rehabil 2022 Jun 24;4(3):e1097-e1102. Epub 2022 May 24.

Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, Washington, U.S.A.

Purpose: To compare stiffness, strain, and load to failure of 4- versus 5-strand hamstring anterior cruciate ligament reconstruction human tendon allografts with femoral suspensory and tibial interference screw fixation.

Methods: Allograft hamstring tendons were used to create 10 four-strand (4S) and 10 five-strand (5S) grafts. Grafts were fixed to a uniaxial electromechanical load system via a femoral cortical suspensory button and a bioabsorbable interference screw in bone analogue. Read More

View Article and Full-Text PDF
June 2022
Similar Publications

Nanomicelles-in-coaxial nanofibers with exit channels as a transdermal delivery platform for smoking cessation.

Authors:
Sarah Yahia Ahmed S Abo Dena Rasha M El Nashar Ibrahim M El-Sherbiny

J Mater Chem B 2022 Jun 16. Epub 2022 Jun 16.

Nanomedicine Lab, Center for Materials Science (CMS), Zewail City of Science and Technology, 6th of October, Giza 12578, Egypt.

Smoking is a life-threatening habit; that is why many nicotine-replacement therapies (NRTs), which include chewing gums, nicotine patches, lozenges, mouth sprays, inhalers and nasal sprays that are usually administered for 8-12 weeks, have been reported for smoking cessation. We report the fabrication of patches comprising nanomicelles-in-coaxial nanofibers (NFs) for the transdermal delivery of varenicline (VAR) tartrate, a partial agonist of the α4β2 receptor subtype, for smoking cessation. The cores of the fabricated coaxial NF structures are composed of polyethylene oxide, VAR-loaded Pluronic F127 nanomicelles (NPs) and free VAR, while the shell consists of a blend of cellulose acetate (CA) and polycaprolactone (PCL) in a ratio of 1 : 9 (w/w) that incorporates 50% (wt%) free VAR. Read More

View Article and Full-Text PDF
June 2022
Similar Publications

Fatigue and failure analysis of restored endodontically treated maxillary incisors without a dowel or ferrule.

Authors:
Marco Aurelio de Carvalho Priscilla Cardoso Lazari-Carvalho Altair Antoninha Del Bel Cury Pascal Magne

J Prosthet Dent 2022 Jun 12. Epub 2022 Jun 12.

Tenured Associate Professor, Don & Sybil Harrington Foundation Professor of Esthetic Dentistry, Department of Restorative Sciences, The Herman Ostrow School of Dentistry, University of Southern California (USC), Los Angeles, Calif.

Statement Of Problem: Information on the survival and mode of failure of endodontically treated incisors without a ferrule and restored without dowels is lacking.

Purpose: The purpose of this in vitro study was to compare the survival and failure mode of endodontically treated incisors without a ferrule and restored with bonded ceramic crowns and various composite resin foundation restorations without dowels with a control group with fiber dowels.

Material And Methods: Forty-five decoronated endodontically treated bovine incisors without ferrule were divided into 3 experimental groups and restored with different adhesive foundation restorations without dowel: nanohybrid composite resin (Nd), bulk-fill composite resin foundation restoration (NdB), and fiber-reinforced bulk-fill composite resin (NdFR). Read More

View Article and Full-Text PDF
June 2022
Similar Publications
}