    Evaluation of In Vivo Volumetric Dosimetry for Prostate Cancer Using Electronic Portal Imaging Device.
    Nihon Hoshasen Gijutsu Gakkai Zasshi 2016;72(11):1128-1136
    Department of Radiology, University of Tokyo Hospital.
    Purpose: Volumetric modulated arc therapy (VMAT) is capable of acquiring projection images using electronic portal imaging device (EPID). Commercial EPID-based dosimetry software, dosimetry check (DC), allows in vivo dosimetry using projection images. The purpose of this study was to evaluate in vivo dosimetry for prostate cancer using VMAT.

    Method: VMAT plans were generated for eight patients with prostate cancer using treatment planning system (TPS), and patient quality assurances (QAs) were carried out with phantom. We analyzed five plans as phantom study and five plans as patient study. Projection images were acquired during VMAT delivery. DC converted acquired images into fluence images and used a pencil beam algorithm to calculate dose distributions delivered on the CT images of the phantom and the patients. We evaluated isocenter point doses and gamma analysis in both studies and dose indexes of planning target volume (PTV), bladder and rectum in patient study.

    Results And Discussion: Dose differences at the isocenter were less than a criterion in both studies. Pass rates of the gamma analysis were less than a criterion by two plans in the phantom study. Dose indexes of reconstructed distribution were lower than original plans and standard deviations of PTV in reconstructed distribution were larger than original plans. The errors were caused by some issues, such as the commissioning of DC, variations in patient anatomy, and patient positioning.

    Conclusion: The method was feasible to non-invasively perform in vivo dose evaluation for prostate cancer using VMAT.

    Similar Publications

    Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
    Med Phys 2006 Oct;33(10):3921-30
    Department of Radiation Oncology, The Netherlands Cancer Institute--Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands.
    The aim of this study was to demonstrate how dosimetry with an amorphous silicon electronic portal imaging device (a-Si EPID) replaced film and ionization chamber measurements for routine pre-treatment dosimetry in our clinic. Furthermore, we described how EPID dosimetry was used to solve a clinical problem. IMRT prostate plans were delivered to a homogeneous slab phantom. Read More
    An in vivo dose verification method for SBRT-VMAT delivery using the EPID.
    Med Phys 2015 Dec;42(12):6955-63
    Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2, Canada; Medical Physics Department, CancerCare Manitoba, 675 McDermot Avenue, Winnipeg, Manitoba R3E 0V9, Canada; and Department of Radiology, University of Manitoba, 820 Sherbrook Street, Winnipeg, Manitoba R3A 1R9, Canada.
    Purpose: Radiation treatments have become increasingly more complex with the development of volumetric modulated arc therapy (VMAT) and the use of stereotactic body radiation therapy (SBRT). SBRT involves the delivery of substantially larger doses over fewer fractions than conventional therapy. SBRT-VMAT treatments will strongly benefit from in vivo patient dose verification, as any errors in delivery can be more detrimental to the radiobiology of the patient as compared to conventional therapy. Read More
    In aqua vivo EPID dosimetry.
    Med Phys 2012 Jan;39(1):367-77
    Department of Radiation Oncology, The Netherlands Cancer Institute--Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands.
    Purpose: At the Netherlands Cancer Institute--Antoni van Leeuwenhoek Hospital in vivo dosimetry using an electronic portal imaging device (EPID) has been implemented for almost all high-energy photon treatments of cancer with curative intent. Lung cancer treatments were initially excluded, because the original back-projection dose-reconstruction algorithm uses water-based scatter-correction kernels and therefore does not account for tissue inhomogeneities accurately. The aim of this study was to test a new method, in aqua vivo EPID dosimetry, for fast dose verification of lung cancer irradiations during actual patient treatment. Read More
    Quasi real time in vivo dosimetry for VMAT.
    Med Phys 2014 Jun;41(6):062103
    Istituto di Fisica, Università Cattolica del Sacro Cuore, Rome 00168, Italy; U.O.C di Fisica Sanitaria, Università Cattolica del Sacro Cuore, Rome 00168, Italy; and Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Roma Tre, Rome 00168, Italy.
    Purpose: Results about the feasibility of a method for quasi real time in vivo dosimetry (IVD) at the isocenter point for volumetric modulated arc therapy (VMAT) are here reported. The method is based on correlations between the EPID signal and the dose on the beam central axis. Moreover, the γ-analysis of EPID images was adopted to verify off-axis reproducibility of fractionated plan delivery. Read More