Differentiation of mild keratoconus from corneal warpage according to topographic inferior steepening based on corneal tomography data.

Authors:
Lia Florim Patrão Ana Laura Caiado Canedo João Luiz Peixoto Braga de Azevedo Rosane Correa Renato Ambrósio

Arq Bras Oftalmol 2016 Jul-Aug;79(4):264-7

Corneal Tomography and Biomechanics Study Group, Rio de Janeiro, RJ, Brazil.

We report two cases of suspicious asymmetric bow tie and inferior steepening on topographic evaluations with reflection (Placido) and projection (Scheimpflug). Rotating Scheimpflug corneal and anterior segment tomography (Oculus Pentacam HR, Wetzlar, Germany)® was performed in the first case, with a maximal keratometric value (Kmax) of 43.2 D and an overall deviation value from the Belin/Ambrósio Enhanced Ectasia Display (BAD-D) of 1.76, which was observed in the study eye (OD). BAD-D was 6.59 in the fellow eye, which had clinical findings that were consistent with keratoconus stage 2. The second case presented with a Kmax of 45.3 D and BAD-D of 0.76 in OD and 1.01 in OS. This patient had discontinued wearing soft contact lens less than 1 day prior to examination. Corneal tomographic data enabled us to distinguish mild or forme fruste keratoconus from contact lens-induced corneal warpage, and similar findings were observed on curvature maps.

Download full-text PDF

Source
http://dx.doi.org/10.5935/0004-2749.20160075DOI Listing
April 2017

Publication Analysis

Top Keywords

corneal warpage
8
inferior steepening
8
corneal
5
belin/ambrósio enhanced
4
prior examination
4
examination corneal
4
deviation belin/ambrósio
4
432 deviation
4
enhanced ectasia
4
ectasia display
4
176 observed
4
bad-d 176
4
day prior
4
display bad-d
4
corneal tomographic
4
tomographic data
4
distinguish mild
4
performed case
4
germany® performed
4
enabled distinguish
4

Similar Publications

Yield of Display Modules of Corneal Tomography for Early Diagnosis of Corneal Ectasia.

Authors:
O Vlasák J Škorpíková Z Hlinomazová V Kalandrová

Cesk Slov Oftalmol 2019 ;74(5):175-183

The thesis deals with comparison of topographic corneal indexes and their importance for the diagnosis of corneal ectatic disease. The corneas with different stages of keratoconus, forme fruste keratoconus, pellucid marginal degeneration, corneal warpage syndrome, and physiological cornea with varying values of regular astigmatism were included in the tested group. The study was conducted in 2015-2018 at the European Eye Clinic Lexum Brno. Read More

View Article and Full-Text PDF
June 2019
Similar Publications

False corneal ectasia in patients referred for corneal crosslinking, topography-guided photorefractive keratectomy, and intrastromal corneal rings.

Authors:
Raymond Stein Ghani Salim

Can J Ophthalmol 2019 06 28;54(3):374-381. Epub 2018 Nov 28.

Bochner Eye Institute, Toronto, Ont.

Objective: To determine the misdiagnosis of ectasia in patients referred for corneal crosslinking and possible topography-guided photorefractive keratectomy (PRK) or intrastromal corneal rings.

Setting: Bochner Eye Institute, Toronto, Ontario, Canada.

Design: Retrospective data review. Read More

View Article and Full-Text PDF
June 2019
Similar Publications

Influence of soft contact lens material on corneal warpage: prevalence and time to resolution.

Authors:
Youssef Rayess Nicolas Arej Youssef Abdel Massih Joelle Antoun Naji Waked

Can J Ophthalmol 2018 04 31;53(2):135-138. Epub 2017 Oct 31.

Faculty of Medicine, Saint-Joseph University, Beirut, Lebanon; Department of Ophthalmology, Hôtel-Dieu de France Hospital, Beirut, Lebanon.

Objective: Corneal warpage represents a reversible distortion of the corneal surface induced by soft contact lens (SCL) wear. The aim of the study is to assess the influence of SCL materials, age, wearing duration, cylindrical refraction, and spherical equivalence on the prevalence and time to resolution of corneal warpage.

Methods: This is an interventional prospective study in which SCL wearers volunteered to remove their SCLs and underwent, on each visit, a corrected distance visual acuity and anterior and posterior segment evaluation, along with keratometry measurement and corneal topography. Read More

View Article and Full-Text PDF
April 2018
Similar Publications

Corneal Warpage due to Massage Following Eyelid Surgery.

Authors:
Evan Kalin-Hajdu Qinyun Wang Stephen D McLeod M Reza Vagefi

Ophthalmic Plast Reconstr Surg 2018 Jul/Aug;34(4):e142

Department of Ophthalmology, University of California, San Francisco, San Francisco, California, U.S.A.

View Article and Full-Text PDF
August 2018
Similar Publications

A protocol for topographic-guided corneal repair utilizing the US Food and Drug Administration-approved Wavelight Contoura.

Authors:
Manoj Motwani

Clin Ophthalmol 2017 23;11:573-581. Epub 2017 Mar 23.

Motwani LASIK Institute, San Diego, CA, USA.

Purpose: To demonstrate how Wavelight Contoura can be used to repair corneas damaged by trauma and prior poor surgical outcomes.

Methods: Four representative eyes are presented that show different scenarios in which highly irregular corneas can be corrected with Wavelight Contoura using a protocol (named the San Diego Protocol) designed to use the information in Contoura processing. Both laser-assisted in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) were used. Read More

View Article and Full-Text PDF
March 2017
Similar Publications
Save 15% Survey
© 2021 PubFacts.
  • About PubFacts
  • Privacy Policy
  • Sitemap