Multicenter evaluation of dynamic three-dimensional magnetic resonance myocardial perfusion imaging for the detection of coronary artery disease defined by fractional flow reserve.

Circ Cardiovasc Imaging 2015 May;8(5)

From the University and ETH Zurich, Zurich, Switzerland (R.M., L.W., S.K.); University Heart Center, University Hospital Zurich, Zurich, Switzerland (R.M., M.N., A.G., T.F.L.); German Heart Institute, Berlin, Germany (R.G., B.S., E.F.); King's College London, London, United Kingdom (R.J., E.N.); University of Leeds, Leeds, United Kingdom (M.M., S.P.); and University Hospital RWTH Aachen, Germany (M.F., S.R., C.K., N.M.).

Background: First-pass myocardial perfusion cardiovascular magnetic resonance (CMR) imaging yields high diagnostic accuracy for the detection of coronary artery disease (CAD). However, standard 2D multislice CMR perfusion techniques provide only limited cardiac coverage, and hence considerable assumptions are required to assess myocardial ischemic burden. The aim of this prospective study was to assess the diagnostic performance of 3D myocardial perfusion CMR to detect functionally relevant CAD with fractional flow reserve (FFR) as a reference standard in a multicenter setting.

Methods And Results: A total of 155 patients with suspected CAD listed for coronary angiography with FFR were prospectively enrolled from 5 European centers. 3D perfusion CMR was acquired on 3T MR systems from a single vendor under adenosine stress and at rest. All CMR perfusion analyses were performed in a central laboratory and blinded to all clinical data. One hundred fifty patients were successfully examined (mean age 62.9±10 years, 45 female). The prevalence of CAD defined by FFR (<0.8) was 56.7% (85 of 150 patients). The sensitivity and specificity of 3D perfusion CMR were 84.7% and 90.8% relative to the FFR reference. Comparison to quantitative coronary angiography (≥50%) yielded a prevalence of 65.3%, sensitivity and specificity of 76.5% and 94.2%, respectively.

Conclusions: In this multicenter study, 3D myocardial perfusion CMR proved highly diagnostic for the detection of significant CAD as defined by FFR.

Download full-text PDF

Source
https://www.ahajournals.org/doi/10.1161/CIRCIMAGING.114.0030
Publisher Site
http://dx.doi.org/10.1161/CIRCIMAGING.114.003061DOI Listing
May 2015

Publication Analysis

Top Keywords

myocardial perfusion
12
fractional flow
8
perfusion cmr
8
cmr perfusion
8
detection coronary
8
artery disease
8
coronary artery
8
magnetic resonance
8
flow reserve
8
perfusion
6
cmr
5
listed coronary
4
standard multicenter
4
reference standard
4
coronary angiography
4
ffr reference
4
cad listed
4
suspected cad
4
reserve ffr
4
settingmethods total
4

Similar Publications