Pubfacts - Scientific Publication Data
  • Categories
  • |
  • Journals
  • |
  • Authors
  • Login
  • Categories
  • Journals

Search Our Scientific Publications & Authors

Publications
  • Publications
  • Authors
find publications by category +
Translate page:

Cyclotorsional and non-cyclotorsional components of eye rotation observed from sitting to supine position.

Authors:
Adam L Prickett Kelly Bui Joelle Hallak Pejman Bakhtiyari Jose de la Cruz Dimitri T Azar Wallace Chamon

Br J Ophthalmol 2015 Jan 12;99(1):49-53. Epub 2014 Aug 12.

Department of Ophthalmology and Visual Sciences, College of Medicine, University of Illinois at Chicago-UIC, USA Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, Federal University of Sao Paulo-UNIFESP, Brazil.

Purpose: Evaluate average cyclotorsional and non-cyclotorsional components (NCY) of eye rotation from sitting to supine, and associate average cyclotorsion to different variables.

Methods: Medical records of patients who underwent bilateral sequential laser refractive surgery were retrospectively evaluated. Recorded variables included the patient's age, refraction, automated keratometry, pupil displacement and eye rotation from sitting to supine position. Measured iris rotation (total rotation, TR) was decomposed into two components: NCY, defined as the common rotation component of each eye of the same patient, and cyclotorsional component (CY), defined as the assumed independent eye rotation for each eye in relation to the face, so that TR=NCY+CY. Cyclotorsion ratio (CR) was calculated as CR=|CY|/|TR|, and used to correlate CY with TR for each eye.

Results: Data from 310 eyes of 155 patients were evaluated. TR was +1.43° ±3.41° (-8.30° to +9.20°). Average CYs and NCYs per patient were +1.43°±2.04° (-3.15± to +7.40°) and -0.28°±2.72° (-6.85° to +7.15°), respectively. TR demonstrated that 40.6% and 8.4% of patients presented bilateral excyclotorsion and incyclotorsion, respectively. When excluding NCYs, average CYs demonstrated that 74.2% of patients presented excyclotorsion and 23.9% presented incyclotorsion. CR demonstrated that TR represented from 75% to 125% of average CY in 19.68% of the eyes. TR overestimated and underestimated average CYs above these limits in 52.26% and 28.06% of the eyes, respectively. There was no statistical association between average CYs and the different variables.

Discussion: This study demonstrates that most of the rotations previously attributed to torsional components were probably due to NCYs, such as postural misalignments. Apparently, the amplitude of cyclotorsional movements is smaller than observed in previous reports, and could not be associated with any studied variable.

Download full-text PDF

Source
http://dx.doi.org/10.1136/bjophthalmol-2014-304975DOI Listing
January 2015

Publication Analysis

Top Keywords

eye rotation
16
average cys
16
sitting supine
12
supine position
8
patients presented
8
rotation sitting
8
components ncy
8
cyclotorsional non-cyclotorsional
8
non-cyclotorsional components
8
average
7
rotation
7
eye
6
correlate eyeresults
4
eyeresults data
4
cyclotorsional
4
statistical association
4
association average
4
ratio calculated
4
calculated cr=|cy|/|tr|
4
cr=|cy|/|tr| correlate
4

Keyword Occurance

Similar Publications

How resilient is reading to letter rotations? A parafoveal preview investigation.

Authors:
María Fernández-López Jonathan Mirault Jonathan Grainger Manuel Perea

J Exp Psychol Learn Mem Cogn 2021 Apr 15. Epub 2021 Apr 15.

Departamento de Metodologia and ERI-Lectura.

Skilled readers have developed a certain amount of tolerance to variations in the visual form of words (e.g., CAPTCHAs, handwritten text, etc. Read More

View Article and Full-Text PDF
April 2021
Similar Publications

Objective evaluation of static and dynamic behavior of different toric silicone-hydrogel contact lenses.

Authors:
Ángel Sánchez-García Javier González-Pérez

Cont Lens Anterior Eye 2021 Apr 9:101437. Epub 2021 Apr 9.

Ocular Surface and Contact Lens Research Laboratory, Faculty of Optics and Optometry, University of Santiago de Compostela, Spain.

Purpose: The present study aimed to estimate how orientation position, recovery time, and contact lens decentration, associated with visual performance, may vary on several designs of the most recent toric silicone-hydrogel toric contact lenses in two-time different moments.

Methods: To evaluate the toric silicone-hydrogel toric contact lens position and stability, it was conducted with a prospective, observational, randomized, and single-center case series including 95 astigmatic eyes wearing four toric silicone-hydrogel toric contact lenses for two weeks. Orientation and decentration were analyzed with ImageJ software from video-frames extracted with a Python application. Read More

View Article and Full-Text PDF
April 2021
Similar Publications

Identifying solution strategies in a mentalrotation test with gender-stereotyped objects.

Authors:
Mirko Saunders Claudia M Quaiser-Pohl

J Eye Mov Res 2021 Mar 10;13(6). Epub 2021 Mar 10.

University of Koblenz-Landau, Germany.

Many studies deal with solution strategies in mental-rotation tests. The approaches range from global analysis, attention to object parts, holistic and piecemeal strategy to a combined strategy. Other studies do not speak of strategies, but of holistic or piecemeal processes or even of holistic or piecemeal rotation. Read More

View Article and Full-Text PDF
March 2021
Similar Publications

Torsional component of microsaccades during fixation and quick phases during optokinetic stimulation.

Authors:
Shirin Sadeghpour Jorge Otero-Millan

J Eye Mov Res 2020 Oct 20;13(5). Epub 2020 Oct 20.

Johns Hopkins University, Baltimore, MD, USA.

While many studies have characterized the eye movements during visual fixation, includ-ing microsaccades, in most cases only horizontal and vertical components have been rec-orded and analyzed. Thus, little is known about the torsional component of microsaccades. We took advantage of a newly developed software and hardware to record eye movements around the three axes of rotation during fixation and torsional optokinetic stimulus. Read More

View Article and Full-Text PDF
October 2020
Similar Publications

Positional head-eye tracking outside the lab: an open-source solution.

Authors:
Peter Hausamann Christian Sinnott Paul R MacNeilage

Proc Eye Track Res Appl Symp 2020 Jun;2020

University of Nevada, Reno, Reno, Nevada.

Simultaneous head and eye tracking has traditionally been confined to a laboratory setting and real-world motion tracking limited to measuring linear acceleration and angular velocity. Recently available mobile devices such as the Pupil Core eye tracker and the Intel RealSense T265 motion tracker promise to deliver accurate measurements outside the lab. Here, the researchers propose a hard- and software framework that combines both devices into a robust, usable, low-cost head and eye tracking system. Read More

View Article and Full-Text PDF
June 2020
Similar Publications
© 2021 PubFacts.
  • About PubFacts
  • Privacy Policy
  • Sitemap