Pubfacts - Scientific Publication Data
  • Categories
  • |
  • Journals
  • |
  • Authors
  • Login
  • Categories
  • Journals

Search Our Scientific Publications & Authors

Publications
  • Publications
  • Authors
find publications by category +
Translate page:

Remote-controlled magnetic pulmonary vein isolation using a new three-dimensional non-fluoroscopic navigation system: a single-centre prospective study.

Authors:
Antoine Da Costa Mouna Ben H'dech Cécile Romeyer-Bouchard Laurence Bisch Alexis Gate-Martinet Marie Levallois Karl Isaaz

Arch Cardiovasc Dis 2013 Aug-Sep;106(8-9):423-32. Epub 2013 Jul 29.

Service de Cardiologie, Hôpital Nord, CHU de Saint-Étienne, Université Jean-Monnet, 42055 Saint-Étienne Cedex 2, France. Electronic address:

Background: Catheter ablation of atrial fibrillation (AF) focuses on pulmonary vein isolation (PVI), but the procedure is associated with significant X-ray exposure. Few data exist concerning the combination of remote magnetic navigation (RMN) and a new three-dimensional non-fluoroscopic navigation system (Carto(®) 3), which facilitates precise catheter navigation and limits X-ray exposure.

Aims: To assess the efficacy and extent of fluoroscopic exposure associated with the combination of RMN and the Carto 3 system in patients requiring AF ablation.

Methods: Between January and September 2011, catheter ablation was performed remotely using the Carto 3 system in 81 consecutive patients who underwent PVI for symptomatic drug-refractory AF. The radiofrequency generator was set to a fixed power ≤ 35W. The primary endpoint was wide-area circumferential PVI confirmed by spiral catheter recording during ablation and including additional lesion lines (left atrial roof and coronary sinus defragmentation) or complex fractionated atrial electrograms for persistent AF. Secondary endpoints included procedural data, complications and freedom from atrial tachycardia (AT)/AF.

Results: Mean age was 60 ± 9 years; 20% were women; 73% had symptomatic paroxysmal AF; 27% had persistent AF. The CHA2DS2-VASc score was 1.2 ± 1. Median procedure time was 3.5 ± 1 hours; median total X-ray exposure time was 13 ± 7 minutes; transseptal puncture and catheter positioning took 8 ± 4 minutes, left atrium electroanatomical reconstruction 1 ± 4 minutes and catheter ablation 3.5 ± 5minutes. Recurrences were AT (n=3; 3.7%), paroxysmal AF (n=8; 9.9%) and persistent AF (n=4; 4.9%); redo ablation was performed in these 15 (19%) patients. After a median follow-up of 15 ± 6 months and a single procedure, 71% of patients were free of symptoms; 84% remained asymptomatic after two procedures.

Conclusions: RMN with irrigated catheters combined with the Carto 3 system can be effectively performed in patients requiring AF ablation with minimal use of fluoroscopy, but larger randomized studies are warranted.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acvd.2013.04.008DOI Listing
June 2014

Publication Analysis

Top Keywords

carto system
12
catheter ablation
12
three-dimensional non-fluoroscopic
8
navigation system
8
vein isolation
8
non-fluoroscopic navigation
8
ablation performed
8
patients requiring
8
x-ray exposure
8
pulmonary vein
8
catheter
6
ablation
6
system
5
patients
5
atrial tachycardia
4
tachycardia at/afresults
4
at/afresults age
4
included procedural
4
complications freedom
4
data complications
4

Keyword Occurance

Similar Publications

Is the extent of left atrial fibrosis associated with body mass index in patients undergoing pulmonary vein isolation for atrial fibrillation?

Authors:
Janko Szavits Nossan Igor Šesto Krešimir Štambuk Tomislav Šipić Robert Bernat Ivan Gudelj Luka Rotkvić Marinko Žulj Jure Mirat

Kardiol Pol 2021 Mar 25. Epub 2021 Mar 25.

Background: Left atrial (LA) fibrosis is associated with a higher rate of recurrence of atrial fibrillation (AF) after pulmonary vein isolation (PVI). Body mass index (BMI) is strongly associated with the prevalence of AF, but there is insufficient data about the association between BMI and LA fibrosis.

Aims: To examine the association between LA fibrosis and BMI in patients with AF undergoing PVI. Read More

View Article and Full-Text PDF
March 2021
Similar Publications

Focally Appearing Activation Map of a Reentrant Tachycardia Using a New Coherent Mapping Tool.

Authors:
Abdul Q Haji Asim Kichloo John G Symons Khalil Kanjwal

J Innov Card Rhythm Manag 2021 Mar 15;12(3):4442-4445. Epub 2021 Mar 15.

Division of Cardiology, McLaren Greater Lansing Hospital, Michigan State University, Lansing, MI, USA.

Here, we discuss mapping of an atrioventricular reciprocating tachycardia (AVRT) using color-coding and a coherence module of the CARTO mapping system (Biosense Webster, Diamond Bar, CA, USA). AVRT is a reentry tachycardia and, when the atrial exit site of the arrhythmia circuit was mapped in this case, it appeared to have a focal centrifugal activation pattern as depicted by coherent mapping. Read More

View Article and Full-Text PDF
March 2021
Similar Publications

Utility of coherent and ripple mapping for post-mitral valve plasty biatrial macro-re-entrant tachycardia: a case report.

Authors:
Yuichiro Sagawa Yasuteru Yamauchi Kaoru Okishige Tetsuo Sasano

Eur Heart J Case Rep 2021 Feb 12;5(2):ytaa547. Epub 2021 Jan 12.

Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ward, Tokyo 113-8510, Japan.

Background : Biatrial tachycardia (BiAT) is a rare form of atrial macro-re-entrant tachycardia. Precise identification of interatrial connections and circuits of the BiAT is difficult. And incomplete understanding of the re-entrant circuit may lead to unnecessary ablation, thus increasing the risk of complications. Read More

View Article and Full-Text PDF
February 2021
Similar Publications

[Efficacy and safety of segmental radiofrequency ablation for isolation of the superior vena cava in patients with atrial fibrillation].

Authors:
Y W Chen Z Wang L P Sun X J Chen X L Wang R Li J Z Dong

Zhonghua Xin Xue Guan Bing Za Zhi 2021 Mar 24;49(3):229-235. Epub 2021 Mar 24.

Department of Cardiology, First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China.

To analyze the three-dimensional distribution of functional sinus node, right phrenic nerve and superior vena cava(SVC)-right atrial muscle sleeves by three-dimensional electrophysiological technique in patients with atrial fibrillation (AF), and to investigate the efficacy and safety of segmental radiofrequency catheter ablation (RFCA) for isolation of superior vena cava in these patients In this retrospective study, we enrolled 136 AF patients who underwent first RFCA in the First Affiliated Hospital of Zhengzhou University from July 2018 to June 2019 and all patients underwent SVC isolation under sinus rhythm. Baseline clinical data of patients were collected. The functional sinus node was defined by activation mapping, pacing was guided by three-dimensional mapping (Carto) system, localization of the right phrenic nerve was defined by pacing map, the superior vena cava-right atrial muscle sleeves was determined according to the change of potential during SVC isolation, segmental RFCA was performed for SVC isolation, the three-dimensional distribution of functional sinus node, right phrenic nerve and superior vena cava(SVC)-right atrial muscle sleeves was determined by three-dimensional electrophysiological technique. Read More

View Article and Full-Text PDF
March 2021
Similar Publications

Non-fluoroscopic radiofrequency catheter ablation of right- and left-sided ventricular arrhythmias.

Authors:
Karkowski Grzegorz Marcin Kuniewicz Edward Koźluk Tomasz Chyży Andrzej Ząbek Michał Dusza Jacek Lelakowski

Postepy Kardiol Interwencyjnej 2020 Sep 2;16(3):321-329. Epub 2020 Oct 2.

Institute of Cardiology, John Paul II Hospital, Jagiellonian University Medical College, Krakow, Poland.

Introduction: Radiofrequency catheter ablation (RFCA) is an important method of treatment of ventricular arrhythmias (VAs). In the majority of RFCA, fluoroscopy is used, exposing patients and medical staff to all related side effects. Current experience of non-fluoroscopic (NF)-RFCA in VAs from the left side is limited. Read More

View Article and Full-Text PDF
September 2020
Similar Publications
© 2021 PubFacts.