Validation of an in-house made rapid urease test kit against the commercial CLO-test in detecting Helicobacter pylori infection in the patients with gastric disorders.

J Res Med Sci 2012 Mar;17(3):212-6

Department of Bacteriology, Prof. Alborzi Clinical Microbiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.

Background: H. pylori is a urease positive organism, and this activity in a gastric biopsy could be considered as a proof of the presence of H. pylori. For the reasons of high price and difficult accessibility to the commercial CLO-test in Iran, we designed an affordable equivalent test with high specificity, accuracy and availability.

Methods: Biopsy samples from 80 symptomatic patients with gastrointestinal problems were included in this study. The results of our in-house made rapid urease kit were compared with the commercial CLO-test up to 3 hours and 24 hours after inoculation of the biopsy samples. Culture results and gram staining were proposed as gold standard.

Results: Helicobacter pylori was isolated from 36 patients (45.0%) after cultivation of biopsy samples. After 3 hours, 33 (91.6%) cases of positive samples for H. pylori, showed urease positive reaction using both, in-house made and CLO-test kits. However, 2 (5.5%) cases showed urease reaction at 24 hours using both the kits. The specificity of 100% was determined for both, in-house made and commercial CLO-test kits after 3 hours. The sensitivity for both the kits was estimated at 97.1% after 3hours. However, after 24 hours, sensitivity and specificity of 97.1% and 88.64% was estimated for the in-house and 97.2 % and 95.4% for the commercial CLO-test kits, respectively.

Conclusion: Specificity and sensitivity of 100% and 97.1 % for up to 3 hours follow biopsy sampling, could be considered as an advantage for our in-house rapid urease kit. Moreover, the rapid urease agar media designed in our lab is cost-effective with adequate sensitivity and specificity levels for the detection of H. pylori, compared with the commercial CLO-test.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3527036PMC
March 2012

Publication Analysis

Top Keywords

commercial clo-test
24
rapid urease
16
clo-test kits
12
biopsy samples
12
in-house rapid
12
urease kit
8
helicobacter pylori
8
sensitivity specificity
8
urease positive
8
hours sensitivity
8
compared commercial
8
pylori urease
8
hours
7
clo-test
7
urease
7
commercial
6
pylori
6
specificity
5
in-house
5
biopsy
5

Similar Publications