Enhanced optical flow field of left ventricular motion using quasi-Gaussian DCT filter.

Adv Exp Med Biol 2011 ;696:461-9

Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi, 43600, Selangor, Malaysia.

Left ventricular motion estimation is very important for diagnosing cardiac abnormality. One of the popular techniques, optical flow technique, promises useful results for motion quantification. However, optical flow technique often failed to provide smooth vector field due to the complexity of cardiac motion and the presence of speckle noise. This chapter proposed a new filtering technique, called quasi-Gaussian discrete cosine transform (QGDCT)-based filter, to enhance the optical flow field for myocardial motion estimation. Even though Gaussian filter and DCT concept have been implemented in other previous researches, this filter introduces a different approach of Gaussian filter model based on high frequency properties of cosine function. The QGDCT is a customized quasi discrete Gaussian filter in which its coefficients are derived from a selected two-dimensional DCT. This filter was implemented before and after the computation of optical flow to reduce the speckle noise and to improve the flow field smoothness, respectively. The algorithm was first validated on synthetic echocardiography image that simulates a contracting myocardium motion. Subsequently, this method was also implemented on clinical echocardiography images. To evaluate the performance of the technique, several quantitative measurements such as magnitude error, angular error, and standard error of measurement are computed and analyzed. The final motion estimation results were in good agreement with the physician manual interpretation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-1-4419-7046-6_46DOI Listing
June 2011

Publication Analysis

Top Keywords

optical flow
20
flow field
12
motion estimation
12
gaussian filter
12
ventricular motion
8
left ventricular
8
dct filter
8
flow technique
8
speckle noise
8
motion
7
filter
7
flow
6
coefficients derived
4
filter coefficients
4
customized quasi
4
quasi discrete
4
discrete gaussian
4
derived selected
4
implemented computation
4
reduce speckle
4

Similar Publications

2-D left ventricular flow estimation by combining speckle tracking with Navier-Stokes-based regularization: an in silico, in vitro and in vivo study.

Ultrasound Med Biol 2015 Jan 15;41(1):99-113. Epub 2014 Nov 15.

Lab on Cardiovascular Imaging and Dynamics, KU Leuven, Leuven, Belgium.

Despite the availability of multiple ultrasound approaches to left ventricular (LV) flow characterization in two dimensions, this technique remains in its childhood and further developments seem warranted. This article describes a new methodology for tracking the 2-D LV flow field based on ultrasound data. Hereto, a standard speckle tracking algorithm was modified by using a dynamic kernel embedding Navier-Stokes-based regularization in an iterative manner. Read More

View Article and Full-Text PDF
January 2015

Left ventricular border tracking using cardiac motion models and optical flow.

Ultrasound Med Biol 2011 Apr 3;37(4):605-16. Epub 2011 Mar 3.

Biomedical Engineering, Thoraxcenter, Erasmus MC, The Netherlands.

The use of automated methods is becoming increasingly important for assessing cardiac function quantitatively and objectively. In this study, we propose a method for tracking three-dimensional (3-D) left ventricular contours. The method consists of a local optical flow tracker and a global tracker, which uses a statistical model of cardiac motion in an optical-flow formulation. Read More

View Article and Full-Text PDF
April 2011

Review of myocardial motion estimation methods from optical flow tracking on ultrasound data.

Conf Proc IEEE Eng Med Biol Soc 2006;2006:1537-40

Ecole Nationale Supérieure des Télécommunications, LTCI CNRS UMR 5141, 46 rue Barrault, Paris, France, 75013.

Quantitative analysis of cardiac motion is of great clinical interest in assessment of ventricular function. Ultrasound imaging, especially matrix transducers acquiring real-time three dimensional data, provide valuable information, from which quantitative measures of cardiac function can be extracted via optical flow computation. Such analysis requires tracking of the image brightness patterns with underlying assumptions of visual persistency. Read More

View Article and Full-Text PDF
March 2008

Analysis of motion tracking in echocardiographic image sequences: influence of system geometry and point-spread function.

Ultrasonics 2010 Mar 19;50(3):373-86. Epub 2009 Sep 19.

CREATIS, CNRS UMR 5520, INSERM U 630, INSA-Lyon F-69621, France.

This paper focuses on motion tracking in echocardiographic ultrasound images. The difficulty of this task is related to the fact that echographic image formation induces decorrelation between the underlying motion of tissue and the observed speckle motion. Since Meunier's seminal work, this phenomenon has been investigated in many simulation studies as part of speckle tracking or optical flow-based motion estimation techniques. Read More

View Article and Full-Text PDF
March 2010