High frequency ultrasound measurement of digital dermal thickness in systemic sclerosis.

Ann Rheum Dis 2010 Jun 17;69(6):1140-3. Epub 2009 Sep 17.

Department of Biomedicine, Division of Rheumatology AOUC, Centre Denothe, University of Florence, Villa Monna Tessa, Viale Pieraccini 18, Florence 50139, Italy.

Background: Currently, assessment of dermal thickness in systemic sclerosis (SSc) is performed by palpation and assessment using the modified Rodnan skin score (mRSS).

Objective: To verify whether high frequency ultrasound (US) may be a reliable and a reproducible method to measure digital dermal thickness.

Methods: In 70 patients with SSc, skin thickness was evaluated with US by 2 observers at 2 different sites on the second digit of the dominant limb to determine the interobserver variability. Patients and controls were examined twice by the first observer for intraobserver variability. Patients were divided into three subgroups according to the phase of the disease (oedematous, fibrotic or atrophic).

Results: At both examined areas, US showed a significant dermal thickening (p<0.001) in the whole group of patients with SSc. A low intraobserver and interobserver variability was found. A highly significant correlation between the global mRSS and the local dermal thickness at the two examined sites (p=0.032, p=0.021) was detected. Skin thickness was significantly higher in the oedematous than in the fibrotic group (p<0.001) and significantly higher in the fibrotic and the oedematous group (p<0.001) than in the atrophic group (p<0.002).

Conclusions: US is a reliable tool giving reproducible results, and is able to detect digital dermal thickening in SSc.

Download full-text PDF

Source
http://ard.bmj.com/cgi/doi/10.1136/ard.2009.114843
Publisher Site
http://dx.doi.org/10.1136/ard.2009.114843DOI Listing
June 2010
31 Reads

Publication Analysis

Top Keywords

dermal thickness
8
thickness systemic
8
systemic sclerosis
8
variability patients
8
digital dermal
8
high frequency
8
frequency ultrasound
8
interobserver variability
4
determine interobserver
4
ultrasound reliable
4
reliable reproducible
4
limb determine
4
rodnan skin
4
verify high
4
score mrssobjective
4
patients controls
4
controls examined
4
dominant limb
4
mrssobjective verify
4
skin score
4

Similar Publications