Comparison of a new enzymatic assay with a high-performance liquid chromatography/ ultraviolet detection method for therapeutic drug monitoring of mycophenolic acid in adult liver transplant recipients.

Liver Transpl 2008 Dec;14(12):1745-51

Laboratoire de Pharmacologie-Toxicologie, Service de Pharmacie, GH Cochin-Saint Vincent-de-Paul, Paris, France.

Mycophenolic acid (MPA) is used to prevent graft rejection. The methods used for determining the plasma MPA concentration in liver transplant recipients are the enzyme-multiplied immunoassay technique (EMIT), high-performance liquid chromatography with ultraviolet detection (HPLC-UV), and most recently mass spectrometry. EMIT has been reported to overestimate the MPA concentration by 30% to 35% in comparison with HPLC-UV. Recently, a new automated enzymatic assay based on inosine monophosphate dehydrogenase inhibition has been designed. The aim of the present investigation was to compare this technique with validated HPLC-UV in adult liver transplant recipients treated with tacrolimus or cyclosporine. One hundred seventy-six samples from 50 adult liver transplant recipients were analyzed with both techniques. Patients received mycophenolate mofetil (2 or 3 times daily) coadministered with cyclosporine microemulsion (n = 18) or tacrolimus (n = 32). Samples were drawn over an interdose interval during the early or late posttransplantation period. The Passing-Bablok regression and Bland-Altman plot were used to compare the 2 techniques. The Passing-Bablock regression, calculated from 166 samples, showed very good agreement between the enzymatic assay and the HPLC-UV method: enzymatic assay = 1.0204 (95% confidence interval, 0.9942, 1.0478) x HPLC-UV + 0.0201 (-0.0442, 0.0882). No significant bias was found between the techniques (Bland-Altman plot), and the median relative difference was 2.7% (95% confidence interval, -0.4, 6.6). In conclusion, the enzymatic assay showed an excellent correlation with HPLC-UV. Therefore, this method was proved valid and reliable for the monitoring of the plasma MPA concentration in adult liver transplant recipients treated with cyclosporine microemulsion or tacrolimus.

Download full-text PDF

Source
http://dx.doi.org/10.1002/lt.21607DOI Listing
December 2008
10 Reads

Publication Analysis

Top Keywords

liver transplant
20
enzymatic assay
20
transplant recipients
20
adult liver
16
mpa concentration
12
recipients treated
8
ultraviolet detection
8
95% confidence
8
mycophenolic acid
8
confidence interval
8
high-performance liquid
8
bland-altman plot
8
cyclosporine microemulsion
8
hplc-uv method
8
microemulsion tacrolimus
8
plasma mpa
8
hplc-uv
6
liver
5
transplant
5
assay
5

References

(Supplied by CrossRef)

Similar Publications