k-Space and time sensitivity encoding-accelerated myocardial perfusion MR imaging at 3.0 T: comparison with 1.5 T.

Authors:
Sven Plein Juerg Schwitter Daniel Suerder John P Greenwood Peter Boesiger Sebastian Kozerke

Radiology 2008 Nov;249(2):493-500

Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland.

Purpose: To determine the feasibility and diagnostic accuracy of high-spatial-resolution myocardial perfusion magnetic resonance (MR) imaging at 3.0 T by using k-space and time (k-t) domain undersampling with sensitivity encoding (SENSE), or k-t SENSE. Data were compared with results of k-t SENSE-accelerated high-spatial-resolution perfusion MR imaging at 1.5 T and standard-resolution acquisition at 3.0 T.

Materials And Methods: The study was reviewed and approved by the local ethics review board; informed consent was obtained. k-t SENSE perfusion MR imaging was performed at 1.5 and 3.0 T (fivefold k-t SENSE acceleration; spatial resolution, 1.3 x 1.3 x 10 mm). Fourteen volunteers were studied at rest; 37 patients were studied during adenosine-induced stress. In volunteers, comparison was also made with standard-resolution (2.5 x 2.5 x 10 mm) twofold SENSE perfusion MR imaging results at 3.0 T. Image quality, artifact scores, signal-to-noise ratios (SNRs), and contrast enhancement ratios were derived. In patients, diagnostic accuracy of visual analysis to detect stenosis of more than 50% narrowing in diameter at quantitative coronary angiography was determined by using receiver operator characteristic (ROC) analysis.

Results: In volunteers, image quality and artifact scores were similar for 3.0- and 1.5-T k-t SENSE perfusion MR imaging, while SNR was higher (11.6 vs 5.6) and contrast enhancement ratio was lower (1.1 vs 1.5, P = .012) at 3.0 T. Compared with standard-resolution perfusion MR imaging, image quality was higher for 3.0-T k-t SENSE (3.6 vs 3.1, P = .04), endocardial dark rim artifacts were reduced (artifact thickness, 1.6 vs 2.4 mm, P < .001), and contrast enhancement ratios were similar. In patients, areas under the ROC curve for detection of coronary stenosis were 0.89 and 0.80 (P = .21) for 3.0 and 1.5 T, respectively.

Conclusion: k-t SENSE-accelerated high-spatial-resolution perfusion MR imaging at 3.0 T is feasible, with similar artifacts and diagnostic accuracy as those at 1.5 T. Compared with standard-resolution twofold SENSE perfusion MR imaging, image quality at k-t SENSE MR imaging is improved and artifacts are reduced.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2492080017DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2586821PMC
November 2008

Publication Analysis

Top Keywords

perfusion imaging
32
k-t sense
24
sense perfusion
16
image quality
16
contrast enhancement
12
imaging image
12
diagnostic accuracy
12
imaging
10
sense
9
k-t
9
perfusion
9
high-spatial-resolution perfusion
8
enhancement ratios
8
artifacts reduced
8
artifact scores
8
quality artifact
8
standard-resolution twofold
8
sense-accelerated high-spatial-resolution
8
k-space time
8
k-t sense-accelerated
8

Similar Publications

[Cardiac MRI today].

Authors:
Wolfgang Rudolf Bauer

Dtsch Med Wochenschr 2021 Mar 1;146(5):344-350. Epub 2021 Mar 1.

Since its beginning, 30 years ago, magnetic resonance imaging of the heart made tremendous progress. Starting from an almost experimental level in the 90 s it has now become a routine tool within cardiac diagnostics. This article presents a selection of present applications of cardiac magnetic resonance imaging. Read More

View Article and Full-Text PDF
March 2021
Similar Publications

The diagnostic function of intravoxel incoherent motion for distinguishing between pilocytic astrocytoma and ependymoma.

Authors:
Nguyen Minh Duc

PLoS One 2021 1;16(3):e0247899. Epub 2021 Mar 1.

Doctoral Program, Department of Radiology, Hanoi Medical University, Hanoi, Vietnam.

Introduction: Intravoxel incoherent motion (IVIM) imaging concurrently measures diffusion and perfusion parameters and has potential applications for brain tumor classification. However, the effectiveness of IVIM for the differentiation between pilocytic astrocytoma and ependymoma has not been verified. The aim of this study was to determine the potential diagnostic role of IVIM for the distinction between ependymoma and pilocytic astrocytoma. Read More

View Article and Full-Text PDF
March 2021
Similar Publications

A microfluidic bubble perfusion device for brain slice culture.

Authors:
Amirus Saleheen Debalina Acharyya Rebecca A Prosser Christopher A Baker

Anal Methods 2021 Mar 1. Epub 2021 Mar 1.

Department of Chemistry, University of Tennessee, Knoxville, Tennessee 37996, USA and Department of Chemistry and Biochemistry, New Mexico State University, MSC 3C, PO Box 30001, Las Cruces, New Mexico 88003, USA.

Ex vivo brain slice cultures are utilized as analytical models for studying neurophysiology. Common approaches to maintaining slice cultures include roller tube and membrane interface techniques. The rise of organ-on-chip technologies has demonstrated the value of microfluidic perfusion culture systems for sampling and analysis of complex biology under well-controlled in vitro or ex vivo conditions. Read More

View Article and Full-Text PDF
March 2021
Similar Publications

An integrated microfluidic bubble pocket for long-term perfused three-dimensional intestine-on-a-chip model.

Authors:
Kang Kug Paul Lee Toru Matsu-Ura Andrew E Rosselot Taylor R Broda James M Wells Christian I Hong

Biomicrofluidics 2021 Jan 17;15(1):014110. Epub 2021 Feb 17.

Computational and Molecular Biology Laboratory, Department of Pharmacology and Systems Physiology, University of Cincinnati, Cincinnati, Ohio 45267, USA.

Perfused three-dimensional (3D) cultures enable long-term growth and monitoring of 3D organoids making them well-suited for investigating organoid development, growth, and function. One of the limitations of this long-term on-chip perfused 3D culture is unintended and disruptive air bubbles. To overcome this obstacle, we invented an imaging platform that integrates an innovative microfluidic bubble pocket for long-term perfused 3D culture of gastrointestinal (GI) organoids. Read More

View Article and Full-Text PDF
January 2021
Similar Publications

Application of Brain Perfusion SPECT in the Evaluation of Response to Zolpidem Therapy in Consciousness Disorder Due to Traumatic Brain Injury.

Authors:
Hosseinali Khalili Abbas Rakhsha Tahereh Ghaedian Amin Niakan Nahid Masoudi

Indian J Nucl Med 2020 Oct-Dec;35(4):315-320. Epub 2020 Oct 21.

Nuclear Medicine and Molecular Imaging Research Center, Namazi Teaching Hospital, Shiraz University of Medical Sciences, Shiraz, Iran.

Background: Traumatic brain injury (TBI) is a critical health problem with various comorbidities and socioeconomic consequences. Tending to increase in recent decades, TBI results in more cases of consciousness disorders including vegetative state (VS)/minimally conscious state (MCS). However, no definite or effective treatment still exists for these conditions. Read More

View Article and Full-Text PDF
October 2020
Similar Publications
© 2021 PubFacts.
  • About PubFacts
  • Privacy Policy
  • Sitemap