Comparison of side hole versus non side hole high flow hemodialysis catheters.

Hemodial Int 2006 Jan;10(1):63-7

Interventional Radiology, Yale New Haven Hospital and VA Connecticut Healthcare System, New Haven, Connecticut 06525, USA.

Current literature suggests that side holes may be detrimental to dialysis catheter performance. Today, these catheters are primarily available with side holes. The purpose of this study was to compare flow rates, infection rate, and survival of side hole vs. non side hole hemodialysis catheters. Over a 16-month period patients were arbitrarily assigned to either a 14.5 F MAHURKAR MAXID cuffed dual lumen tunneled catheter with side holes or a 14.5 F MAHURKAR MAXID cuffed dual lumen tunneled catheter without side holes ("non side hole catheters"). We performed a retrospective analysis of catheter flow rates, patency, catheter survival, and catheter-related infections. Information was gathered for the life of the catheter or up to 28 weeks. A total of 54 patients were enrolled in the study. Thirty-seven of 54 (68%) patients received a catheter with side holes for a total of 3,930 catheter days and 17/54 (32%) received a similar catheter without side holes for a total of 2,188 catheter days. Catheter infection necessitating removal of the catheter occurred in 10/37 catheters with side holes and 1/17 without side holes. Infection rates per 1,000 catheter days were 2.545 with side holes and 0.254 without side holes (p<0.001). Slightly improved catheter survival (p<0.05) was recorded with the non side hole catheters. No insertion complication (e.g., air embolization, bleeding, or kinking) occurred with either catheter. One catheter without side holes had to be repositioned 5 days after insertion because of poor flows. No significant difference was recorded in mean blood flow rates between the catheters. Results indicate reduced catheter infection rate in hemodialysis patients with the use of non side hole dual lumen tunneled cuffed catheters.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1542-4758.2006.01176.xDOI Listing
January 2006
11 Reads

Publication Analysis

Top Keywords

side holes
40
side hole
20
catheter side
16
side
14
catheter
13
catheter days
12
holes
10
catheters side
8
received catheter
8
mahurkar maxid
8
tunneled catheter
8
145 mahurkar
8
maxid cuffed
8
cuffed dual
8
dual lumen
8
lumen tunneled
8
flow rates
8
holes total
8
hemodialysis catheters
8
hole
5

Altmetric Statistics

References

(Supplied by CrossRef)

Twardowski ZJ et al.
J Vascular Access 2001

De Moor B et al.
Artif Organs 1994

Shaffer D et al.
ASAIO J 1992

Mosquera DA et al.
Nephrol Dial Transplant 1992

Swartz RD et al.
J Am Soc Nephrol 1994

McDowell DE et al.
Am Surgeon 1993

Capdevila JA et al.
Nephrol Dial Transplant 1993

Lund GB et al.
Radiology 1996

Similar Publications