Design of a Single-Tooth Model and Its Application in Oral Scan System Assessment.

Scanning 2021 21;2021:8891396. Epub 2021 Mar 21.

Stomatological Materials Laboratory, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, Shandong 271016, China.

Intraoral scanners have been widely used in the application of dentistry. Accuracy includes trueness and precision; they have an important position in the assessment of intraoral scanners. The existing standard models are divided into the inlay and the crown, but the operation is relatively complicated. In this study, in order to simplify the current standard model, we designed a new integration model to compare the accuracy of two intraoral scanners (CEREC and TRIOS) and an extraoral scanner (SHINING). The coordinate measuring machine measured value is the gold standard. Values of the length and angle were analyzed by converting the scanned digital impressions into an STL (standard triangulation language) format to evaluate the accuracy of the intraoral scanner and to verify the feasibility of the designed model. The result shows that the integration model can be successfully scanned and imaged. In the case of the powder-free integration model, intraoral scanner precision, trueness, 3D fitting, and imaging are better than the extraoral scanner. It can be seen straightly from the measurement result and the 3D fitting result that the intraoral scanner can acquire the shape of the standard model integrally with good repeatability. Therefore, it can be concluded that TRIOS is superior to CEREC and SHINING in accuracy, and the integration model is feasible as a reference in the examination of intraoral scanners. The performance of the newly designed integration model that can be scanned is clinically significant, suggesting that this model can be used as a standard reference model.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1155/2021/8891396DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8009709PMC
March 2021

Effects of relining materials on the flexural strength of relined thermoplastic denture base resins.

J Adv Prosthodont 2018 Oct 22;10(5):361-366. Epub 2018 Oct 22.

Department of Prosthodontics, Korea University Guro Hospital, Seoul, Republic of Korea.

Purpose: The aim of this study was to evaluate the effects of relining materials on the flexural strength of relined thermoplastic denture base resins (TDBRs).

Materials And Methods: For shear bond strength testing, 120 specimens were fabricated using four TDBRs (EstheShot-Bright, Acrytone, Valplast, Weldenz) that were bonded with three autopolymerizing denture relining resins (ADRRs: Vertex Self-Curing, Tokuyama Rebase, Ufi Gel Hard) with a bond area of 6.0 mm in diameter and were assigned to each group (n=10). For flexural strength testing, 120 specimens measuring 64.0×10.0×3.3 mm (ISO-1567:1999) were fabricated using four TDBRs and three ADRRs and were assigned to each group (n=10). The thickness of the specimens measured 2.0 mm of TDBR and 1.3 mm of ADRR. Forty specimens using four TDBRs and 30 specimens using ADRRs served as the control. All specimens were tested on a universal testing machine. For statistical analysis, Analysis of variance (ANOVA) with Tukey's test as post hoc and Spearman's correlation coefficient analysis (=.05) were performed.

Results: Acry-Tone showed the highest shear bond strength, while Weldenz demonstrated the lowest bond strength between TDBR and ADRRs compared to other groups. EstheShot-Bright exhibited the highest flexural strength, while Weldenz showed the lowest flexural strength. Relined EstheShot-Bright demonstrated the highest flexural strength and relined Weldenz exhibited the lowest flexural strength (<.05). Flexural strength of TDBRs (=.001) and shear bond strength (=.013) exhibited a positive correlation with the flexural strength of relined TDBRs.

Conclusion: The flexural strength of relined TDBRs was affected by the flexural strength of the original denture base resins and bond strength between denture base resins and relining materials.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.4047/jap.2018.10.5.361DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6202434PMC
October 2018
-->