Publications by authors named "Rodney D Wiersma"

15Publications

Optimization based trajectory planning for real-time 6DoF robotic patient motion compensation systems.

PLoS One 2019 11;14(1):e0210385. Epub 2019 Jan 11.

Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, IL 60637, United States of America.

View Article

Download full-text PDF

Source
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0210385PLOS
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6329492PMC
October 2019

Use of a laser-guided collimation system to perform direct kilovoltage x-ray spectra measurements on a linear accelerator onboard imager.

Med Phys 2018 Nov 9;45(11):4869-4876. Epub 2018 Oct 9.

Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL, 60637-1470, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.13188DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6234071PMC
November 2018

Towards frameless maskless SRS through real-time 6DoF robotic motion compensation.

Phys Med Biol 2017 Nov 13;62(23):9054-9066. Epub 2017 Nov 13.

Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, IL 60637-1470, United States of America.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/aa93d2DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5927375PMC
November 2017

Use of proximal operator graph solver for radiation therapy inverse treatment planning.

Med Phys 2017 Apr;44(4):1246-1256

Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, IL, 60637, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.12165DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5508626PMC
April 2017

Technical Note: High temporal resolution characterization of gating response time.

Med Phys 2016 Jun;43(6):2802-2806

Department of Radiation and Cellular Oncology, University of Chicago, 5841 S. Maryland Avenue, Chicago, Illinois 60637 and Department of Radiation Oncology, University of Illinois at Chicago, 1801 West Tayor Street, Chicago, Illinois 60612.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.4948500DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4866946PMC
June 2016

Spatial and rotational quality assurance of 6DOF patient tracking systems.

Med Phys 2016 Jun;43(6):2785-2793

Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois 60637-1470.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.4948506DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4866954PMC
June 2016

Robotic real-time translational and rotational head motion correction during frameless stereotactic radiosurgery.

Med Phys 2015 Jun;42(6):2757-63

Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois 60637.

View Article

Download full-text PDF

Source
http://doi.wiley.com/10.1118/1.4919279
Publisher Site
http://dx.doi.org/10.1118/1.4919279DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4433479PMC
June 2015

Development of a 6DOF robotic motion phantom for radiation therapy.

Med Phys 2014 Dec;41(12):121704

Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois 60637-1470.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.4900828DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4235649PMC
December 2014

Combined MV + kV inverse treatment planning for optimal kV dose incorporation in IGRT.

Phys Med Biol 2014 Apr 10;59(7):1607-21. Epub 2014 Mar 10.

The University of Chicago, Department of Radiation and Cellular Oncology, 5758 South Maryland Avenue, MC 9006, Chicago, IL 60637, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/59/7/1607DOI Listing
April 2014

Spatial and temporal performance of 3D optical surface imaging for real-time head position tracking.

Med Phys 2013 Nov;40(11):111712

Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois 60637-1470.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.4823757DOI Listing
November 2013

An EPID based method for performing high accuracy calibration between an optical external marker tracking device and the LINAC reference frame.

Med Phys 2012 May;39(5):2771-9

Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, IL 60637, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.3703836DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3350542PMC
May 2012

Improvements in dose accuracy delivered with static-MLC IMRT on an integrated linear accelerator control system.

Med Phys 2012 May;39(5):2456-62

Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, IL 60637, USA.

View Article

Download full-text PDF

Source
http://doi.wiley.com/10.1118/1.3701778
Publisher Site
http://dx.doi.org/10.1118/1.3701778DOI Listing
May 2012

Optimized hybrid megavoltage-kilovoltage imaging protocol for volumetric prostate arc therapy.

Int J Radiat Oncol Biol Phys 2010 Oct 14;78(2):595-604. Epub 2010 May 14.

Department of Radiation Oncology, Stanford University School of Medicine, California 94305-5847, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijrobp.2009.11.056DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4131869PMC
October 2010

Development of a frameless stereotactic radiosurgery system based on real-time 6D position monitoring and adaptive head motion compensation.

Phys Med Biol 2010 Jan 17;55(2):389-401. Epub 2009 Dec 17.

Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, IL 60637, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/55/2/004DOI Listing
January 2010