Phase-only modulation with two vertical aligned liquid crystal devices.

Opt Express 2020 Nov;28(23):34180-34189

Spatial Light Modulators (SLMs) are widely used in several fields of optics such as adaptive optics. SLMs based on Liquid Crystal (LC) devices allow a dynamic and easy representation of two-dimensional phase maps. A drawback of these devices is their elevated cost, preventing a massive use of the technology. We present a more affordable approach based on the serial arrangement of vertical aligned LC devices, with characteristics of phase modulation similar to a widely used parallel aligned LC device. We discuss the peculiarities of the approach, the performance and some potential areas of applications.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.410429DOI Listing
November 2020

Assessment of subjective refraction with a clinical adaptive optics visual simulator.

J Cataract Refract Surg 2019 01 8;45(1):87-93. Epub 2018 Oct 8.

Laboratorio de Óptica, Universidad de Murcia, Murcia, Spain.

Purpose: To clinically validate an adaptive optics visual simulator (VAO) that measures subjective refraction and visual acuity.

Setting: Optics Laboratory, University of Murcia, Murcia, Spain.

Design: Prospective case series.

Methods: Using the adaptive optics visual simulator, 2 examiners measured the subjective refraction and visual acuity in healthy eyes of volunteers; 1 examiner also used a trial frame as a gold standard. The interexaminer reproducibility and agreement with the gold standard were estimated using the following statistical parameters: limits of agreement from Bland-Altman analysis, significance between differences (P value), and intraclass correlation coefficient (ICC).

Results: Seventy-six eyes of 38 volunteers were measured. Interexaminer reproducibility for subjective refraction was excellent (ICC ≥0.96; P > .05), with low 95% confidence interval (CI) values for the power vectors M (spherical equivalent of the given refractive error), J0 (Jackson cross-cylinder, axes at 180 degrees and 90 degrees), and J45 (Jackson cross-cylinder, axes at 45 degrees and 135 degrees) (±0.51 diopter [D], ±0.14 D, and ±0.14 D, respectively). No significant differences in subjective refraction and visual acuity were found between the visual simulator and gold standard (P > .05), with 95% CIs for M, J0, and J45 (subjective refraction) of ±0.67 D, ±0.14 D, and ±0.16 D, respectively, and a ±0.10 logarithm of the minimum angle of resolution (visual acuity).

Conclusion: Subjective refraction results using the adaptive optics visual simulator agreed with those of the gold standard and can be used as the baseline for visual simulation of any optical corneal profile or intraocular lens design for refractive surgery patients.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2018.08.022DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6320260PMC
January 2019

Chromatic aberration control with liquid crystal spatial phase modulators.

Opt Express 2017 May;25(9):9793-9801

The chromatic behavior of diffractive optical elements, exhibiting 2π-wrapped phase profiles, implemented into liquid crystal spatial light modulators (LC-SLM) is described. A wrapped phase map is only equivalent to the original continuous profile for the design wavelength while at other wavelengths there are unwanted phase jumps and the profile does not correspond to a pure defocus. For those conditions the wrapped profile behaves as a multiple order lens (multi-focal lens). The optical power dispersion for each order is linearly proportional to the wavelength, while the energy of each order depends on the design wavelength and the material dispersion. For practical purposes, for most of the visible range only first order (main defocus) is relevant but two other orders may also be considered depending on the actual PSF of the system. As an application, we demonstrate that the longitudinal chromatic aberration of the eye can be compensated by the diffractive lens dispersion when the appropriate defocus is programmed into the SLM.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.25.009793DOI Listing
May 2017

Interferometric method for phase calibration in liquid crystal spatial light modulators using a self-generated diffraction-grating.

Opt Express 2016 Jun;24(13):14159-71

An auto-referenced interferometric method for calibrating phase modulation of parallel-aligned liquid crystal (PAL) spatial light modulators (SLM) is described. The method is experimentally straightforward, robust, and requires solely of a collimated beam, with no need of additional optics. This method uses the SLM itself to create a tilted plane wave and a reference wave which mutually interfere. These waves are codified by means of a binary diffraction grating and a uniformly distributed gray level area (piston) into the SLM surface. Phase shift for each gray level addressed to the piston section can then be evaluated. Phase modulation on the SLM can also be retrieved with the proposed method over spatially resolved portions of the surface. Phase information obtained with this novel method is compared to other well established calibration procedures, requiring extra elements and more elaborated optical set-ups. The results show a good agreement with previous methods. The advantages of the new method include high mechanical stability, faster performance, and a significantly easier practical implementation.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.24.014159DOI Listing
June 2016

Night myopia is reduced in binocular vision.

J Vis 2016 06;16(8):16

Night myopia, which is a shift in refraction with light level, has been widely studied but still lacks a complete understanding. We used a new infrared open-view binocular Hartmann-Shack wave front sensor to quantify night myopia under monocular and natural binocular viewing conditions. Both eyes' accommodative response, aberrations, pupil diameter, and convergence were simultaneously measured at light levels ranging from photopic to scotopic conditions to total darkness. For monocular vision, reducing the stimulus luminance resulted in a progression of the accommodative state that tends toward the subject's dark focus or tonic accommodation and a change in convergence following the induced accommodative error. Most subjects presented a myopic shift of accommodation that was mitigated in binocular vision. The impact of spherical aberration on the focus shift was relatively small. Our results in monocular conditions support the hypothesis that night myopia has an accommodative origin as the eye progressively changes its accommodation state with decreasing luminance toward its resting state in total darkness. On the other hand, binocularity restrains night myopia, possibly by using fusional convergence as an additional accommodative cue, thus reducing the potential impact of night myopia on vision at low light levels.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1167/16.8.16DOI Listing
June 2016

Location of achromatizing pupil position and first Purkinje reflection in a normal population.

Invest Ophthalmol Vis Sci 2015 Jan 22;56(2):962-6. Epub 2015 Jan 22.

Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), Murcia, Spain.

Purpose: Quality of vision in patients who have undergone corneal refractive surgery depends upon the optimal centration of the procedures used. The center of the pupil is used as a reference point in some corneal ablation procedures. The achromatic axis would be a more sensible option from an optical point of view, but it is not as readily detectable. As an alternative, other refractive techniques, like the small aperture corneal inlay for presbyopia correction, use the corneal reflex (first Purkinje image). To assess the relative position of these two marks, we developed a new instrument to simultaneously measure both the first Purkinje image (PI) and the intersection of the achromatic axis with the pupil plane.

Methods: The apparatus records images of the pupil and the PI when illuminated with a circle of infrared light-emitting diodes. A second optical path allows determination of the achromatic axis by using a subjective method. Both the positions of the PI and the achromatic axis intersection are determined simultaneously.

Results: A series of data were obtained in 48 eyes. The mean location of the achromatic point relative to the PI was [x = -0.05 ± 0.15 mm; y = 0.09 ± 0.18 mm]. Considered individually, in 55% of eyes, the distance between locations is less than 0.2 mm, and in 95% of eyes, distances are less than 0.4 mm.

Conclusions: On average, achromatic axis crossing of the pupil and PI locations coincides within measurement errors. Although there was some intersubject variability, differences in location were less than 0.6 mm in all measured eyes.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1167/iovs.14-16108DOI Listing
January 2015

Comparison of binocular through-focus visual acuity with monovision and a small aperture inlay.

Biomed Opt Express 2014 Oct 2;5(10):3355-66. Epub 2014 Sep 2.

Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain.

Corneal small aperture inlays provide extended depth of focus as a solution to presbyopia. As this procedure is becoming more popular, it is interesting to compare its performance with traditional approaches, such as monovision. Here, binocular visual acuity was measured as a function of object vergence in three subjects by using a binocular adaptive optics vision analyzer. Visual acuity was measured at two luminance levels (photopic and mesopic) under several optical conditions: 1) natural vision (4 mm pupils, best corrected distance vision), 2) pure-defocus monovision ( + 1.25 D add in the nondominant eye), 3) small aperture monovision (1.6 mm pupil in the nondominant eye), and 4) combined small aperture and defocus monovision (1.6 mm pupil and a + 0.75 D add in the nondominant eye). Visual simulations of a small aperture corneal inlay suggest that the device extends DOF as effectively as traditional monovision in photopic light, in both cases at the cost of binocular summation. However, individual factors, such as aperture centration or sensitivity to mesopic conditions should be considered to assure adequate visual outcomes.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/BOE.5.003355DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4206307PMC
October 2014

Binocular open-view instrument to measure aberrations and pupillary dynamics.

Opt Lett 2014 Aug;39(16):4773-5

We have designed and built a binocular Hartmann-Shack wave-front sensor using a single microlens array and camera for real-time aberration measurement of both eyes in an open-view configuration. Furthermore, the use of a long wavelength (1050 nm) laser diode makes the illumination source completely invisible, so that measurements can be unobtrusively performed while the subject stares at the visual world under realistic conditions. The setup provides a large dynamic range and simultaneous measurements of convergence, pupil size, accommodation, and aberrations. The open-view design not only offers the possibility of measuring the subject's ocular optics under natural conditions but also allows coupling the device with other existing vision testing instruments and setups, which increases its potential to become a powerful tool for different visual optics studies.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.39.004773DOI Listing
August 2014

Binocular visual acuity for the correction of spherical aberration in polychromatic and monochromatic light.

J Vis 2014 Feb 11;14(2). Epub 2014 Feb 11.

Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Murcia, Spain.

Correction of spherical (SA) and longitudinal chromatic aberrations (LCA) significantly improves monocular visual acuity (VA). In this work, the visual effect of SA correction in polychromatic and monochromatic light on binocular visual performance is investigated. A liquid crystal based binocular adaptive optics visual analyzer capable of operating in polychromatic light is employed in this study. Binocular VA improves when SA is corrected and LCA effects are reduced separately and in combination, resulting in the highest value for SA correction in monochromatic light. However, the binocular summation ratio is highest for the baseline condition of uncorrected SA in polychromatic light. Although SA correction in monochromatic light has a greater impact monocularly than binocularly, bilateral correction of both SA and LCA may further improve binocular spatial visual acuity which may support the use of aspheric-achromatic ophthalmic devices, in particular, intraocular lenses (IOLs).
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1167/14.2.8DOI Listing
February 2014

Impact on stereo-acuity of two presbyopia correction approaches: monovision and small aperture inlay.

Biomed Opt Express 2013 Jun 8;4(6):822-30. Epub 2013 May 8.

Laboratorio de Óptica, Instituto Universitario de investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), E-30100 Murcia, Spain.

Some of the different currently applied approaches that correct presbyopia may reduce stereovision. In this work, stereo-acuity was measured for two methods: (1) monovision and (2) small aperture inlay in one eye. When performing the experiment, a prototype of a binocular adaptive optics vision analyzer was employed. The system allowed simultaneous measurement and manipulation of the optics in both eyes of a subject. The apparatus incorporated two programmable spatial light modulators: one phase-only device using liquid crystal on silicon technology for wavefront manipulation and one intensity modulator for controlling the exit pupils. The prototype was also equipped with a stimulus generator for creating retinal disparity based on two micro-displays. The three-needle test was programmed for characterizing stereo-acuity. Subjects underwent a two-alternative forced-choice test. The following cases were tested for the stimulus placed at distance: (a) natural vision; (b) 1.5 D monovision; (c) 0.75 D monovision; (d) natural vision and small pupil; (e) 0.75 D monovision and small pupil. In all cases the standard pupil diameter was 4 mm and the small pupil diameter was 1.6 mm. The use of a small aperture significantly reduced the negative impact of monovision on stereopsis. The results of the experiment suggest that combining micro-monovision with a small aperture, which is currently being implemented as a corneal inlay, can yield values of stereoacuity close to those attained under normal binocular vision.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/BOE.4.000822DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3675862PMC
June 2013

Binocular adaptive optics vision analyzer with full control over the complex pupil functions.

Opt Lett 2011 Dec;36(24):4779-81

Instituto Universitario de investigación en Óptica y Nanofísica, Universidad de Murcia, Murcia, Spain.

We present a binocular adaptive optics vision analyzer fully capable of controlling both amplitude and phase of the two complex pupil functions in each eye of the subject. A special feature of the instrument is its comparatively simple setup. A single reflective liquid crystal on silicon spatial light modulator working in pure phase modulation generates the phase profiles for both pupils simultaneously. In addition, another liquid crystal spatial light modulator working in transmission operates in pure intensity modulation to produce a large variety of pupil masks for each eye. Subjects perform visual tasks through any predefined variations of the complex pupil function for both eyes. As an example of the system efficiency, we recorded images of the stimuli through the system as they were projected at the subject's retina. This instrument proves to be extremely versatile for designing and testing novel ophthalmic elements and simulating visual outcomes, as well as for further research of binocular vision.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.36.004779DOI Listing
December 2011

Adaptive optics binocular visual simulator to study stereopsis in the presence of aberrations.

J Opt Soc Am A Opt Image Sci Vis 2010 Nov;27(11):A48-55

Laboratorio de Óptica, Centro de Investigación en Óptica y Nanofísica (CiOyN), Universidad de Murcia, Campus de Espinardo, E-30071 Murcia, Spain.

A binocular adaptive optics visual simulator has been devised for the study of stereopsis and of binocular vision in general. The apparatus is capable of manipulating the aberrations of each eye separately while subjects perform visual tests. The correcting device is a liquid-crystal-on-silicon spatial light modulator permitting the control of aberrations in the two eyes of the observer simultaneously in open loop. The apparatus can be operated as an electro-optical binocular phoropter with two micro-displays projecting different scenes to each eye. Stereo-acuity tests (three-needle test and random-dot stereograms) have been programmed for exploring the performance of the instrument. As an example, stereo-acuity has been measured in two subjects in the presence of defocus and/or trefoil, showing a complex relationship between the eye's optical quality and stereopsis. This instrument might serve for a better understanding of the relationship of binocular vision and stereopsis performance and the eye's aberrations.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/JOSAA.27.000A48DOI Listing
November 2010

Hybrid adaptive-optics visual simulator.

Opt Lett 2010 Jan;35(2):196-8

Laboratorio de Optica, Centro de Investigación en Optica y Nanofísica (CiOyN), Universidad de Murcia,Campus de Espinardo, E-30071 Murcia, Spain.

We have developed a hybrid adaptive-optics visual simulator (HAOVS), combining two different phase-manipulation technologies: an optically addressed liquid-crystal phase modulator, relatively slow but capable of producing abrupt or discontinuous phase profiles; and a membrane deformable mirror, restricted to smooth profiles but with a temporal response allowing compensation of the eye's aberration fluctuations. As proof of concept, a phase element structured as discontinuous radial sectors was objectively tested as a function of defocus, and a correction loop was closed in a real eye. To further illustrate the capabilities of the device for visual simulation, we recorded extended images of different stimuli through the system by means of an external camera replacing the subject's eye. The HAOVS is specially intended as a tool for developing new ophthalmic optics elements, where it opens the possibility to explore designs with irregularities and/or discontinuities.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.35.000196DOI Listing
January 2010

Binocular adaptive optics visual simulator.

Opt Lett 2009 Sep;34(17):2628-30

Laboratorio de Optica, Centro de Investigación en Optica y Nanofísica (CiOyN), Universidad de Murcia, Campus de Espinardo, 30071 Murcia, Spain.

A binocular adaptive optics visual simulator is presented. The instrument allows for measuring and manipulating ocular aberrations of the two eyes simultaneously, while the subject performs visual testing under binocular vision. An important feature of the apparatus consists on the use of a single correcting device and wavefront sensor. Aberrations are controlled by means of a liquid-crystal-on-silicon spatial light modulator, where the two pupils of the subject are projected. Aberrations from the two eyes are measured with a single Hartmann-Shack sensor. As an example of the potential of the apparatus for the study of the impact of the eye's aberrations on binocular vision, results of contrast sensitivity after addition of spherical aberration are presented for one subject. Different binocular combinations of spherical aberration were explored. Results suggest complex binocular interactions in the presence of monochromatic aberrations. The technique and the instrument might contribute to the better understanding of binocular vision and to the search for optimized ophthalmic corrections.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.34.002628DOI Listing
September 2009

Wave-aberration control with a liquid crystal on silicon (LCOS) spatial phase modulator.

Opt Express 2009 Jun;17(13):11013-25

Centro de Investigación en Optica y Nanofísica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain.

Liquid crystal on Silicon (LCOS) spatial phase modulators offer enhanced possibilities for adaptive optics applications in terms of response velocity and fidelity. Unlike deformable mirrors, they present a capability for reproducing discontinuous phase profiles. This ability also allows an increase in the effective stroke of the device by means of phase wrapping. The latter is only limited by the diffraction related effects that become noticeable as the number of phase cycles increase. In this work we estimated the ranges of generation of the Zernike polynomials as a means for characterizing the performance of the device. Sets of images systematically degraded with the different Zernike polynomials generated using a LCOS phase modulator have been recorded and compared with their theoretical digital counterparts. For each Zernike mode, we have found that image degradation reaches a limit for a certain coefficient value; further increase in the aberration amount has no additional effect in image quality. This behavior is attributed to the intensification of the 0-order diffraction. These results have allowed determining the usable limits of the phase modulator virtually free from diffraction artifacts. The results are particularly important for visual simulation and ophthalmic testing applications, although they are equally interesting for any adaptive optics application with liquid crystal based devices.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/oe.17.011013DOI Listing
June 2009

A wavelength tunable wavefront sensor for the human eye.

Opt Express 2008 May;16(11):7748-55

Laboratorio de Optica, Universidad de Murcia (LOUM), Centro de Investigación en Optica y Manofísica (CiOyN), Campus de Espinardo, E-30071 Murcia, Spain.

We have designed and assembled an instrument for objective measurement of the eye's wave aberrations for different wavelengths with no modifications in the measurement path. The system consists of a Hartmann-Shack wave-front sensor and a Xe-white-light lamp in combination with a set of interference filters used to sequentially select the measurement wavelength. To show the capabilities of the system and its reliability for measuring at different wavelengths, the ocular aberrations were measured in three subjects at 440, 488, 532, 633 and 694 nm, basically covering the whole visible spectrum. Even for the shortest wavelengths, the illumination level was always several orders of magnitude below the safety limits. The longitudinal chromatic aberration estimates and the wavelength dependence of coma and spherical aberration, as examples of higher-order aberration terms, were compared to the predictions of a chromatic eye model, with good agreement. To our knowledge, this is the first report of a device to objectively determine the spectral fluctuations in the ocular wavefront.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/oe.16.007748DOI Listing
May 2008

Liquid crystal Adaptive Optics Visual Simulator: Application to testing and design of ophthalmic optical elements.

Opt Express 2007 Nov;15(24):16177-88

The concept of Adaptive Optics Visual Simulation applies to the use of an Adaptive Optics system to manipulate ocular aberrations in order to perform visual testing through a modified optics. It can be of interest both to study the visual system and to design new ophthalmic optical elements. In this work, we describe an apparatus based on a liquid crystal programmable phase modulator and explore its capabilities as a tool in the early stages of the design of ophthalmic optical elements with increased depth of field for presbyopic subjects. To illustrate the potential of the instrument, we analyze the performance of two phase profiles obtained by a hybrid optimization procedure. The liquid crystal Adaptive Optics Visual Simulator can be used to experimentally record the point spread function for different vergences in order to objectively measure depth of focus, to perform different psychophysical experiments through the phase profile in order to measure its impact on visual performance, and to study the interaction with the eye's particular aberrations. This approach could save several steps in current procedures of ophthalmic optical design and eventually lead to improved solutions.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/oe.15.016177DOI Listing
November 2007

Statistical description of wave-front aberration in the human eye.

Opt Lett 2002 Jan;27(1):37-9

The wave aberration of the human eye has been measured by means of a Hartmann-Shack wave-front sensor in a population of normal subjects. The set of data has been used to compute the phase distribution, the power spectrum, and the structure function for the average eye to analyze the statistics of the ocular aberration considered as a phase screen. The observed statistics fits the classical Kolmogorov model of a statistically homogeneous medium. These results can be of use in understanding the average effect of aberrations on the retinal image and can serve as a tool to analyze the consequences of ocular-aberration compensation by adaptive optics, customized ophtalmic elements, or refractive surgery.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/ol.27.000037DOI Listing
January 2002

Effect of optical correction and remaining aberrations on peripheral resolution acuity in the human eye.

Opt Express 2007 Oct;15(20):12654-61

Retinal sampling poses a fundamental limit to resolution acuity in the periphery. However, reduced image quality from optical aberrations may also influence peripheral resolution. In this study, we investigate the impact of different degrees of optical correction on acuity in the periphery. We used an adaptive optics system to measure and modify the off-axis aberrations of the right eye of six normal subjects at 20 degrees eccentricity. The system consists of a Hartmann-Shack sensor, a deformable mirror, and a channel for visual testing. Four different optical corrections were tested, ranging from foveal sphero-cylindrical correction to full correction of eccentric low- and high-order monochromatic aberrations. High-contrast visual acuity was measured in green light using a forced choice procedure with Landolt C's, viewed via the deformable mirror through a 4.8-mm artificial pupil. The Zernike terms mainly induced by eccentricity were defocus and with- and against-the-rule astigmatism and each correction condition was successfully implemented. On average, resolution decimal visual acuity improved from 0.057 to 0.061 as the total root-mean-square wavefront error changed from 1.01 mum to 0.05 mum. However, this small tendency of improvement in visual acuity with correction was not significant. The results suggest that for our experimental conditions and subjects, the resolution acuity in the periphery cannot be improved with optical correction.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/oe.15.012654DOI Listing
October 2007

Use of adaptive optics to determine the optimal ocular spherical aberration.

J Cataract Refract Surg 2007 Oct;33(10):1721-6

Department of Applied Research, AMO Groningen BV, Groningen, The Netherlands.

Purpose: To explore the impact of spherical aberration (SA) on contrast sensitivity using an adaptive optics vision simulator to determine the optimal amount of SA to include in customized corrections of wavefront aberrations.

Setting: Laboratorio de Optica, Universidad de Murcia, Murcia, Spain, and AMO Groningen BV, Groningen, The Netherlands.

Methods: An adaptive optics vision simulator consisting of a wavefront sensor, a 97-segmented deformable mirror to induce and correct aberrations of the eye, and a visual testing path was constructed for this study. The deformable mirror allows the effective ocular wavefront aberration to be manipulated and the resulting visual performance to be measured simultaneously. Subjective measurements of contrast sensitivity at 15 cycles per degree were performed with a 4.8 mm pupil in 5 subjects with different levels of naturally occurring SA. Contrast sensitivity was measured when SA values of -0.09 microm, 0.0 microm, 0.09 microm, and 0.182 microm were induced when the other natural aberrations of the eye were present, when the aberrations were corrected, and at defocus values of +/-0.25 diopter (D) and +/-0.50 D.

Results: Subjects experienced peak contrast sensitivity performance with varying levels of SA when their natural aberrations were present; however, average contrast performance peaked at 0 mum of SA. When all higher-order aberrations were corrected, all 5 subjects' peak performance occurred at 0 microm of SA.

Conclusions: The adaptive optics vision simulator reduced the root-mean-square wavefront aberration of the eye by up to a factor of 4 and allowed noninvasive testing of the visual performance resulting from any ocular wavefront aberration introduced by customized correction procedures. This study showed that, on average, contrast performance peaked when SA was completely corrected.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2007.08.001DOI Listing
October 2007

Wide-angle chromatic aberration corrector for the human eye.

J Opt Soc Am A Opt Image Sci Vis 2007 Jun;24(6):1538-44

Laboratorio de Optica, Universidad de Murcia, Spain.

The human eye is affected by large chromatic aberration. This may limit vision and makes it difficult to see fine retinal details in ophthalmoscopy. We designed and built a two-triplet system for correcting the average longitudinal chromatic aberration of the eye while keeping a reasonably wide field of view. Measurements in real eyes were conducted to examine the level and optical quality of the correction. We also performed some tests to evaluate the effect of the corrector on visual performance.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/josaa.24.001538DOI Listing
June 2007

Three-dimensional adaptive optics ultrahigh-resolution optical coherence tomography using a liquid crystal spatial light modulator.

Vision Res 2005 Dec 24;45(28):3432-44. Epub 2005 Oct 24.

Center for Biomedical Engineering and Physics, Vienna University of Medicine, Austria.

A liquid crystal programmable phase modulator (PPM) is used as correcting device in an adaptive optics system for three-dimensional ultrahigh-resolution optical coherence tomography (UHR OCT). The feasibility of the PPM to correct high order aberrations even when using polychromatic light is studied, showing potential for future clinical use. Volumetric UHR OCT of the living retina, obtained with up 25,000A-scans/s and high resolution enables visualization of retinal features that might correspond to groups of terminal bars of photoreceptors at the external limiting membrane.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.visres.2005.08.028DOI Listing
December 2005

Investigating the light absorption in a single pass through the photoreceptor layer by means of the lipofuscin fluorescence.

Vision Res 2005 Jul;45(15):1957-65

Laboratorio de Optica, Universidad de Murcia, Edificio C, Campus de Espinardo, E-30071 Murcia, Spain.

Reflection densitometry has been widely used to measure the density difference of the bleachable cone photopigments in human eyes. Most such measurements make a series of assumptions concerning the amount of scattered light to derive an estimate of the true cone photopigment density from the density difference measurements. The current study made three types of measurements of the light returning from the eye before and after bleaching: the amount of light returning in the "directed" reflection, which is a double-pass estimate of the cone photopigment density; the amount of light in undirected or diffuse reflection; and the amount of fluorescence from lipofuscin in the RPE, which provides a single-pass measurement of optical density difference. For a 1 deg foveally fixated field, the density difference estimates for the three measurements were 0.68, 0.21, and 0.22 respectively. The lipofuscin fluorescence was found to be unguided. The background density difference was non-negligible and very close to the single pass estimate from fluorescence. These measurements each involve potentially different pathways of light through the retina, and therefore place different constraints on models of these pathways. A simple model comparing the directional and the fluorescence optical densities produced retinal coverage estimates around 70-75%. Estimates of the shape factor of the single pass optical Stiles-Crawford effect were evaluated from the dark-adapted and bleached fluorescence measurements. The values were closer to those obtained from psychophysical methods than to the double pass optical Stiles-Crawford shape factors obtained directly from retinal reflectometry.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.visres.2005.01.023DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1479308PMC
July 2005

Imperfect optics may be the eye's defence against chromatic blur.

Nature 2002 May;417(6885):174-6

Schepens Eye Research Institute, 20 Staniford Street, Boston, Massachusetts 02114, USA.

The optics of the eye cause different wavelengths of light to be differentially focused at the retina. This phenomenon is due to longitudinal chromatic aberration, a wavelength-dependent change in refractive power. Retinal image quality may consequently vary for the different classes of cone photoreceptors, cells tuned to absorb bands of different wavelengths. For instance, it has been assumed that when the eye is focused for mid-spectral wavelengths near the peak sensitivities of long- (L) and middle- (M) wavelength-sensitive cones, short-wavelength (bluish) light is so blurred that it cannot contribute to and may even impair spatial vision. These optical effects have been proposed to explain the function of the macular pigment, which selectively absorbs short-wavelength light, and the sparsity of short-wavelength-sensitive (S) cones. However, such explanations have ignored the effect of monochromatic wave aberrations present in real eyes. Here we show that, when these effects are taken into account, short wavelengths are not as blurred as previously thought, that the potential image quality for S cones is comparable to that for L and M cones, and that macular pigment has no significant function in improving the retinal image.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1038/417174aDOI Listing
May 2002

Effect of the polarization on ocular wave aberration measurements.

J Opt Soc Am A Opt Image Sci Vis 2002 Apr;19(4):809-14

Schepens Eye Research Institute, Boston, Massachusetts 02114, USA.

Measurement of the eye's wave aberrations has become fairly standard in recent years. However, most studies have not taken into account the possible influence of the polarization state of light on the wave aberration measurements. The birefringence properties of the eye's optical components, in particular corneal birefringence, can be expected to have an effect on the wave aberration estimates obtained under different states of polarization for the measurement light. In the work described, we used a psychophysical aberrometer (the spatially resolved refractometer) to measure the effect of changes in the polarization state of the illumination light on the eye's wave aberration estimates obtained in a single pass. We find, contrary to our initial expectation, that the polarization state of the measurement light has little influence on the measured wave aberration. For each subject, the differences in wave aberrations across polarization states were of the same order as the variability in aberrations across consecutive estimates of the wave front for the same polarization conditions.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/josaa.19.000809DOI Listing
April 2002