Trials and Tribulations: mHealth Clinical Trials in the COVID-19 Pandemic.

Yearb Med Inform 2021 Apr 21. Epub 2021 Apr 21.

Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, Australia.

Introduction: Mobile phone-based interventions in cardiovascular disease are growing in popularity. A randomised control trial (RCT) for a novel smartphone app-based model of care, named TeleClinical Care - Cardiac (TCC-Cardiac), commenced in February 2019, targeted at patients being discharged after care for an acute coronary syndrome or episode of decompensated heart failure. The app was paired to a digital sphygmomanometer, weighing scale and a wearable fitness band, all loaned to the patient, and allowed clinicians to respond to abnormal readings. The onset of the COVID-19 pandemic necessitated several modifications to the trial in order to protect participants from potential exposure to infection. The use of TCC-Cardiac during the pandemic inspired the development of a similar model of care (TCC-COVID), targeted at patients being managed at home with a diagnosis of COVID-19.

Methods: Recruitment for the TCC-Cardiac trial was terminated shortly after the World Health Organization announced COVID-19 as a global pandemic. Telephone follow-up was commenced, in order to protect patients from unnecessary exposure to hospital staff and patients. Equipment was returned or collected by a 'no-contact' method. The TCC-COVID app and model of care had similar functionality to the original TCC-Cardiac app. Participants were enrolled exclusively by remote methods. Oxygen saturation and pulse rate were measured by a pulse oximeter, and symptomatology measured by questionnaire. Measurement results were manually entered into the app and transmitted to an online server for medical staff to review.

Results: A total of 164 patients were involved in the TCC-Cardiac trial, with 102 patients involved after the onset of the pandemic. There were no hospitalisations due to COVID-19 in this cohort. The study was successfully completed, with only three participants lost to follow-up. During the pandemic, 5 of 49 (10%) of patients in the intervention arm were readmitted compared to 12 of 53 (23%) in the control arm. Also, in this period, 28 of 29 (97%) of all clinically significant alerts received by the monitoring team were managed successfully in the outpatient setting, avoiding hospitalisation. Patients found the user experience largely positive, with the average rating for the app being 4.56 out of 5. 26 patients have currently been enrolled for TCC-COVID. Recruitment is ongoing. All patients have been safely and effectively monitored, with no major adverse clinical events or technical malfunctions. Patient satisfaction has been high.

Conclusion: The TCC-Cardiac RCT was successfully completed despite the challenges posed by COVID-19. Use of the app had an added benefit during the pandemic as participants could be monitored safely from home. The model of care inspired the development of an app with similar functionality designed for use with patients diagnosed with COVID-19.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0041-1726487DOI Listing
April 2021

Recommendation to Use Wearable-Based mHealth in Closed-Loop Management of Acute Cardiovascular Disease Patients During the COVID-19 Pandemic.

IEEE J Biomed Health Inform 2021 04 6;25(4):903-908. Epub 2021 Apr 6.

Because of the rapid and serious nature of acute cardiovascular disease (CVD) especially ST segment elevation myocardial infarction (STEMI), a leading cause of death worldwide, prompt diagnosis and treatment is of crucial importance to reduce both mortality and morbidity. During a pandemic such as coronavirus disease-2019 (COVID-19), it is critical to balance cardiovascular emergencies with infectious risk. In this work, we recommend using wearable device based mobile health (mHealth) as an early screening and real-time monitoring tool to address this balance and facilitate remote monitoring to tackle this unprecedented challenge. This recommendation may help to improve the efficiency and effectiveness of acute CVD patient management while reducing infection risk.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1109/JBHI.2021.3059883DOI Listing
April 2021

Dynamic facial reanimation using active implantable prosthesis: Restoring blink.

J Plast Reconstr Aesthet Surg 2021 Jan 27. Epub 2021 Jan 27.

Faculty of Medicine, University of Sydney, Camperdown, NSW 2006, Australia; Department of Head and Neck Surgery, The Chris O'Brien Lifehouse, Camperdown, NSW 2050, Australia; Sydney Facial Nerve Service, The Chris O'Brien Lifehouse, Camperdown, NSW 2050, Australia.

View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bjps.2021.01.001DOI Listing
January 2021

Assessment of Hypertension Using Clinical Electrocardiogram Features: A First-Ever Review.

Front Med (Lausanne) 2020 4;7:583331. Epub 2020 Dec 4.

Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.

Hypertension affects an estimated 1.4 billion people and is a major cause of morbidity and mortality worldwide. Early diagnosis and intervention can potentially decrease cardiovascular events later in life. However, blood pressure (BP) measurements take time and require training for health care professionals. The measurements are also inconvenient for patients to access, numerous daily variables affect BP values, and only a few BP readings can be collected per session. This leads to an unmet need for an accurate, 24-h continuous, and portable BP measurement system. Electrocardiograms (ECGs) have been considered as an alternative way to measure BP and may meet this need. This review summarizes the literature published from January 1, 2010, to January 1, 2020, on the use of only ECG wave morphology to monitor BP or identify hypertension. From 35 articles analyzed (9 of those with no listed comorbidities and confounders), the P wave, QTc intervals and TpTe intervals may be promising for this purpose. Unfortunately, with the limited number of articles and the variety of participant populations, we are unable to make conclusions about the effectiveness of ECG-only BP monitoring. We provide 13 recommendations for future ECG-only BP monitoring studies and highlight the limited findings in pregnant and pediatric populations. With the advent of convenient and portable ECG signal recording in smart devices and wearables such as watches, understanding how to apply ECG-only findings to identify hypertension early is crucial to improving health outcomes worldwide.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3389/fmed.2020.583331DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7746856PMC
December 2020

Deep Learning for Activity Recognition in Older People Using a Pocket-Worn Smartphone.

Sensors (Basel) 2020 Dec 15;20(24). Epub 2020 Dec 15.

Neuroscience Research Australia, University of New South Wales, Sydney 2031, Australia.

Activity recognition can provide useful information about an older individual's activity level and encourage older people to become more active to live longer in good health. This study aimed to develop an activity recognition algorithm for smartphone accelerometry data of older people. Deep learning algorithms, including convolutional neural network (CNN) and long short-term memory (LSTM), were evaluated in this study. Smartphone accelerometry data of free-living activities, performed by 53 older people (83.8 ± 3.8 years; 38 male) under standardized circumstances, were classified into lying, sitting, standing, transition, walking, walking upstairs, and walking downstairs. A 1D CNN, a multichannel CNN, a CNN-LSTM, and a multichannel CNN-LSTM model were tested. The models were compared on accuracy and computational efficiency. Results show that the multichannel CNN-LSTM model achieved the best classification results, with an 81.1% accuracy and an acceptable model and time complexity. Specifically, the accuracy was 67.0% for lying, 70.7% for sitting, 88.4% for standing, 78.2% for transitions, 88.7% for walking, 65.7% for walking downstairs, and 68.7% for walking upstairs. The findings indicated that the multichannel CNN-LSTM model was feasible for smartphone-based activity recognition in older people.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3390/s20247195DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7765519PMC
December 2020

Estimating Lower Limb Kinematics Using a Lie Group Constrained Extended Kalman Filter with a Reduced Wearable IMU Count and Distance Measurements.

Sensors (Basel) 2020 Nov 29;20(23). Epub 2020 Nov 29.

UCD School of Electrical and Electronic Engineering, University College Dublin, Belfield, 4 Dublin, Ireland.

Tracking the kinematics of human movement usually requires the use of equipment that constrains the user within a room (e.g., optical motion capture systems), or requires the use of a conspicuous body-worn measurement system (e.g., inertial measurement units (IMUs) attached to each body segment). This paper presents a novel Lie group constrained extended Kalman filter to estimate lower limb kinematics using IMU and inter-IMU distance measurements in a reduced sensor count configuration. The algorithm iterates through the prediction (kinematic equations), measurement (pelvis height assumption/inter-IMU distance measurements, zero velocity update for feet/ankles, flat-floor assumption for feet/ankles, and covariance limiter), and constraint update (formulation of hinged knee joints and ball-and-socket hip joints). The knee and hip joint angle root-mean-square errors in the sagittal plane for straight walking were 7.6±2.6∘ and 6.6±2.7∘, respectively, while the correlation coefficients were 0.95±0.03 and 0.87±0.16, respectively. Furthermore, experiments using simulated inter-IMU distance measurements show that performance improved substantially for dynamic movements, even at large noise levels (σ=0.2 m). However, further validation is recommended with actual distance measurement sensors, such as ultra-wideband ranging sensors.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3390/s20236829DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7730686PMC
November 2020

Creation of virtual channels in the retina using synchronous and asynchronous stimulation - a modelling study.

J Neural Eng 2020 Oct 21. Epub 2020 Oct 21.

School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, Shanghai, CHINA.

Objective: Implantable retinal prostheses aim to provide artificial vision to those suffering from retinal degenerative diseases by electrically stimulating the remaining retinal neurons using a multi-electrode array. The spatial resolution of these devices can be improved by creation of so-called virtual channels (VCs) that are commonly achieved through synchronized stimulation of multiple electrodes. It is largely unclear though if VCs can be created using asynchronous stimulation, which was the primary aim of this study.

Approach: A computational model of multi-layered retina and epi-retinal dual-electrode stimulation was developed to simulate the neural activity of populations of retinal ganglion cells (RGCs) using the VC strategy under both synchronous and asynchronous stimulation conditions.

Main Results: Our simulation suggests that VCs can be created using asynchronous stimulation. VC performance under both synchronous and asynchronous stimulation conditions can be improved by optimizing stimulation parameters such as current intensity, current ratio (α) between two electrodes, electrode spacing and the stimulation waveform. In particular, two VC performance measures; (1) linear displacement of the centroid of RGC activation, and (2) the RGC activation size consistency as a function of different current ratios α, have comparable performance under asynchronous and synchronous stimulation with appropriately selected stimulation parameters.

Significance: Our findings support the possibility of creating VCs in the retina under both synchronous and asynchronous stimulation conditions. The results provide theoretical evidence for future retinal prosthesis designs with higher spatial resolution and power efficiency whilst reducing the number of current sources required to achieve these outcomes.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1088/1741-2552/abc3a9DOI Listing
October 2020

Estimating Lower Limb Kinematics using Distance Measurements with a Reduced Wearable Inertial Sensor Count.

Annu Int Conf IEEE Eng Med Biol Soc 2020 07;2020:4858-4862

This paper presents an algorithm that makes novel use of distance measurements alongside a constrained Kalman filter to accurately estimate pelvis, thigh, and shank kinematics for both legs during walking and other body movements using only three wearable inertial measurement units (IMUs). The distance measurement formulation also assumes hinge knee joint and constant body segment length, helping produce estimates that are near or in the constraint space for better estimator stability. Simulated experiments have shown that inter-IMU distance measurement is indeed a promising new source of information to improve the pose estimation of inertial motion capture systems under a reduced sensor count configuration. Furthermore, experiments show that performance improved dramatically for dynamic movements even at high noise levels (e.g., σ = 0.2 m), and that acceptable performance for normal walking was achieved at σ = 0.1 m. Nevertheless, further validation is recommended using actual distance measurement sensors.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC44109.2020.9175684DOI Listing
July 2020

Towards Controlling Functionally-Distinct Retinal Ganglion Cells In Degenerate Retina.

Annu Int Conf IEEE Eng Med Biol Soc 2020 07;2020:3598-3601

Present retinal neuroprostheses have limited performance capabilities due to indiscriminate activation of different neural pathways. Based on our success in differentially activating ON and OFF cells using high frequency stimuli in a healthy retina, in this study we explored whether we could achieve similar differential activation between these two cell types but in degenerate retina. We found that after blocking the synaptic network, ON retinal ganglion cells (RGCs) could be differentially activated at higher frequencies (4 - 6 kHz) and amplitudes (200 - 240 µA), and OFF RGCs at relatively lower amplitudes (80 - 160 µA) across all tested frequencies. We further found that both cell types could be controlled by quickly modulating the frequency using short stimulation bursts. This work takes us one step closer to reducing the likelihood of indiscriminate activation of RGCs by accurately controlling the activation of functionally-distinct neural pathways.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC44109.2020.9176595DOI Listing
July 2020

A Computational Model of Functionally-distinct Cervical Vagus Nerve Fibers.

Annu Int Conf IEEE Eng Med Biol Soc 2020 07;2020:2475-2478

Cervical vagus nerve stimulation (VNS) is a neuromodulation therapy used in the treatment of several chronic disorders. In order to maximize the therapeutic effectiveness of VNS, it has become increasingly important to deliver fiber-specific neurostimulation, so that undesired effects can be minimized. Assessing the activation of different vagal fiber types through electrical stimulation is therefore essential for developing fiber-selective VNS therapies. Towards this goal, we conducted in silico investigations using a generic model of functionally distinct nerve fibers and clinically relevant cuff electrodes using COMSOL. Our model is constrained by histological observations from rat cervical vagus nerves and its outputs are validated against averaged compound nerve action potentials (CNAPs) obtained from rat vagus nerve recordings. We propose this model as an effective tool to design fiber-specific stimulation protocols before testing them in experimental animals.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC44109.2020.9175855DOI Listing
July 2020

Estimating Lower Limb Kinematics Using a Reduced Wearable Sensor Count.

IEEE Trans Biomed Eng 2021 Apr 18;68(4):1293-1304. Epub 2021 Mar 18.

Goal: This paper presents an algorithm for accurately estimating pelvis, thigh, and shank kinematics during walking using only three wearable inertial sensors.

Methods: The algorithm makes novel use of a constrained Kalman filter (CKF). The algorithm iterates through the prediction (kinematic equation), measurement (pelvis position pseudo-measurements, zero velocity update, flat-floor assumption, and covariance limiter), and constraint update (formulation of hinged knee joints and ball-and-socket hip joints).

Results: Evaluation of the algorithm using an optical motion capture-based sensor-to-segment calibration on nine participants (7 men and 2 women, weight [Formula: see text] kg, height [Formula: see text] m, age [Formula: see text] years old), with no known gait or lower body biomechanical abnormalities, who walked within a [Formula: see text] m capture area shows that it can track motion relative to the mid-pelvis origin with mean position and orientation (no bias) root-mean-square error (RMSE) of [Formula: see text] cm and [Formula: see text], respectively. The sagittal knee and hip joint angle RMSEs (no bias) were [Formula: see text] and [Formula: see text], respectively, while the corresponding correlation coefficient (CC) values were [Formula: see text] and [Formula: see text].

Conclusion: The CKF-based algorithm was able to track the 3D pose of the pelvis, thigh, and shanks using only three inertial sensors worn on the pelvis and shanks.

Significance: Due to the Kalman-filter-based algorithm's low computation cost and the relative convenience of using only three wearable sensors, gait parameters can be computed in real-time and remotely for long-term gait monitoring. Furthermore, the system can be used to inform real-time gait assistive devices.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2020.3026464DOI Listing
April 2021

A Novel Automated Blood Pressure Estimation Algorithm Using Sequences of Korotkoff Sounds.

IEEE J Biomed Health Inform 2021 Apr 6;25(4):1257-1264. Epub 2021 Apr 6.

The use of automated non-invasive blood pressure (NIBP) measurement devices is growing, as they can be used without expertise, and BP measurement can be performed by patients at home. Non-invasive cuff-based monitoring is the dominant method for BP measurement. While the oscillometric technique is most common, a few automated NIBP measurement methods have been developed based on the auscultatory technique. Amongst artificial intelligence (AI) techniques, deep learning has received increasing attention in different fields due to its strength in data classification, and feature extraction problems. This paper proposes a novel automated AI-based technique for NIBP estimation from auscultatory waveforms (AWs) based on converting the NIBP estimation problem to a sequence-to-sequence classification problem. To do this, a sequence of segments was first formed by segmenting the AWs, and their corresponding decomposed detail, and approximation parts obtained by wavelet packet decomposition method, and extracting features from each segment. Then, a label was assigned to each segment, i.e. (i) between systolic, and diastolic segments, and (ii) otherwise, and a bidirectional long short term memory recurrent neural network (BiLSTM-RNN) was devised to solve the resulting sequence-to-sequence classification problem. Adopting a 5-fold cross-validation scheme, and using a data base of 350 NIBP recordings gave an average mean absolute error of 1.7±3.7 mmHg for systolic BP (SBP), and 3.4 ±5.0 mmHg for diastolic BP (DBP) relative to reference values. Based on the results achieved, and comparisons made with the existing literature, it is concluded that the proposed automated BP estimation algorithm based on deep learning methods, and auscultatory waveform brings plausible benefits to the field of BP estimation.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1109/JBHI.2020.3012567DOI Listing
April 2021

Robust PPG motion artifact detection using a 1-D convolution neural network.

Comput Methods Programs Biomed 2020 Nov 11;196:105596. Epub 2020 Jun 11.

Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia. Electronic address:

Background And Objectives: Continuous monitoring of physiological parameters such as photoplethysmography (PPG) has attracted increased interest due to advances in wearable sensors. However, PPG recordings are susceptible to various artifacts, and thus reducing the reliability of PPG-driven parameters, such as oxygen saturation, heart rate, blood pressure and respiration. This paper proposes a one-dimensional convolution neural network (1-D-CNN) to classify five-second PPG segments into clean or artifact-affected segments, avoiding data-dependent pulse segmentation techniques and heavy manual feature engineering.

Methods: Continuous raw PPG waveforms were blindly allocated into segments with an equal length (5s) without leveraging any pulse location information and were normalized with Z-score normalization methods. A 1-D-CNN was designed to automatically learn the intrinsic features of the PPG waveform, and perform the required classification. Several training hyperparameters (initial learning rate and gradient threshold) were varied to investigate the effect of these parameters on the performance of the network. Subsequently, this proposed network was trained and validated with 30 subjects, and then tested with eight subjects, with our local dataset. Moreover, two independent datasets downloaded from the PhysioNet MIMIC II database were used to evaluate the robustness of the proposed network.

Results: A 13 layer 1-D-CNN model was designed. Within our local study dataset evaluation, the proposed network achieved a testing accuracy of 94.9%. The classification accuracy of two independent datasets also achieved satisfactory accuracy of 93.8% and 86.7% respectively. Our model achieved a comparable performance with most reported works, with the potential to show good generalization as the proposed network was evaluated with multiple cohorts (overall accuracy of 94.5%).

Conclusion: This paper demonstrated the feasibility and effectiveness of applying blind signal processing and deep learning techniques to PPG motion artifact detection, whereby manual feature thresholding was avoided and yet a high generalization ability was achieved.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2020.105596DOI Listing
November 2020

Advances in Sweat Wearables: Sample Extraction, Real-Time Biosensing, and Flexible Platforms.

ACS Appl Mater Interfaces 2020 Jul 14;12(30):34337-34361. Epub 2020 Jul 14.

Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia.

Wearable biosensors for sweat-based analysis are gaining wide attention due to their potential use in personal health monitoring. Flexible wearable devices enable sweat analysis at the molecular level, facilitating noninvasive monitoring of physiological states via real-time monitoring of chemical biomarkers. Advances in sweat extraction technology, real-time biosensors, stretchable materials, device integration, and wireless digital technologies have led to the development of wearable sweat-biosensing devices that are light, flexible, comfortable, aesthetic, affordable, and informative. Herein, we summarize recent advances of sweat wearables from the aspects of sweat extraction, fabrication of stretchable biomaterials, and design of biosensing modules to enable continuous biochemical monitoring, which are essential for a biosensing device. Key chemical components of sweat, sweat capture methodologies, and considerations of flexible substrates for integrating real-time biosensors with electronics to bring innovations in the art of wearables are elaborated. The strategies and challenges involved in improving the wearable biosensing performance and the perspectives for designing sweat-based wearable biosensing devices are discussed.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.0c07614DOI Listing
July 2020

Neural activity of functionally different retinal ganglion cells can be robustly modulated by high-rate electrical pulse trains.

J Neural Eng 2020 08 4;17(4):045013. Epub 2020 Aug 4.

Graduate School of Biomedical Engineering, UNSW, Sydney, NSW 2052, Australia. These authors contributed equally to this work.

Objective: This study focused on characterising the response of four major functionally-different retinal ganglion cells (RGCs) to a high frequency stimulus (HFS) paradigm.

Approach: We used in vitro patch clamp experiments to assess the viability of evoking a differential response between different RGC types-OFF-Sustained, OFF-Transient, ON-Sustained and ON-Transient-under a wide range of HFS and stimulation amplitude combinations.

Main Results: Of the four types, we found that the OFF-Sustained, OFF-Transient and ON-Transient RGCs could be differentially activated at various frequency and amplitude combinations, in particular, OFF-Sustained cells can be differentially targeted between 20-100 µA at all frequencies, OFF-Transient cells between 150-240 µA at 1 kHz and ON-Transient between 180-240 µA and 4-6 kHz. We further found that this differential activation held true when the stimulus duration was reduced from 300 ms to 50 ms. Finally, we found that the cell spiking response was not primarily dependent on total charge contained in the pulse train or current amplitude alone, but a combination of amplitude and frequency.

Significance: These results indicate that HFS may be a promising method to target functionally-distinct neural pathways in the retina in an effort to improve the vision quality with retinal prostheses.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1088/1741-2552/ab9a97DOI Listing
August 2020

Wearable Sensing and Telehealth Technology with Potential Applications in the Coronavirus Pandemic.

IEEE Rev Biomed Eng 2021 22;14:48-70. Epub 2021 Jan 22.

Coronavirus disease 2019 (COVID-19) has emerged as a pandemic with serious clinical manifestations including death. A pandemic at the large-scale like COVID-19 places extraordinary demands on the world's health systems, dramatically devastates vulnerable populations, and critically threatens the global communities in an unprecedented way. While tremendous efforts at the frontline are placed on detecting the virus, providing treatments and developing vaccines, it is also critically important to examine the technologies and systems for tackling disease emergence, arresting its spread and especially the strategy for diseases prevention. The objective of this article is to review enabling technologies and systems with various application scenarios for handling the COVID-19 crisis. The article will focus specifically on 1) wearable devices suitable for monitoring the populations at risk and those in quarantine, both for evaluating the health status of caregivers and management personnel, and for facilitating triage processes for admission to hospitals; 2) unobtrusive sensing systems for detecting the disease and for monitoring patients with relatively mild symptoms whose clinical situation could suddenly worsen in improvised hospitals; and 3) telehealth technologies for the remote monitoring and diagnosis of COVID-19 and related diseases. Finally, further challenges and opportunities for future directions of development are highlighted.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1109/RBME.2020.2992838DOI Listing
February 2021

Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension.

J Clin Med 2020 Apr 22;9(4). Epub 2020 Apr 22.

Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.

Elevated blood pressure (BP) is a major cause of death, yet hypertension commonly goes undetected. Owing to its nature, it is typically asymptomatic until later in its progression when the vessel or organ structure has already been compromised. Therefore, noninvasive and continuous BP measurement methods are needed to ensure appropriate diagnosis and early management before hypertension leads to irreversible complications. Photoplethysmography (PPG) is a noninvasive technology with waveform morphologies similar to that of arterial BP waveforms, therefore attracting interest regarding its usability in BP estimation. In recent years, wearable devices incorporating PPG sensors have been proposed to improve the early diagnosis and management of hypertension. Additionally, the need for improved accuracy and convenience has led to the development of devices that incorporate multiple different biosignals with PPG. Through the addition of modalities such as an electrocardiogram, a final measure of the pulse wave velocity is derived, which has been proved to be inversely correlated to BP and to yield accurate estimations. This paper reviews and summarizes recent studies within the period 2010-2019 that combined PPG with other biosignals and offers perspectives on the strengths and weaknesses of current developments to guide future advancements in BP measurement. Our literature review reveals promising measurement accuracies and we comment on the effective combinations of modalities and success of this technology.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3390/jcm9041203DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7230564PMC
April 2020

Multimodal Capacitive and Piezoresistive Sensor for Simultaneous Measurement of Multiple Forces.

ACS Appl Mater Interfaces 2020 May 29;12(19):22179-22190. Epub 2020 Apr 29.

School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales 2052, Australia.

Quantitative information on the magnitudes and directions of multiple contacting forces is crucial for a wide range of applications including human-robot interaction, prosthetics, and bionic hands. Herein we report a highly stretchable sensor integrating capacitive and piezoresistive mechanisms that can simultaneously determine multiple forces. The sensor consists of three layers in a sandwich design. The two facesheets serve as both piezoresistive sensors and electrodes for the capacitive sensor, with the core being a porous structure made by using a simple sugar particle template technique to give them high stretchability. The two facesheets contain segregated conductive networks of silver nanowires (AgNWs) and carbon nanofibers (CNFs). By measuring the changes in the electrical resistance of the facesheets and the capacitance between the facesheets, three separate mechanical stimuli can be determined, including normal pressure, in-plane stretch, and transverse shear force. The newly developed multidirectional sensor offers a significant opportunity for the next generation of wearable sensors for human health monitoring and bionic skin for robots.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.0c04448DOI Listing
May 2020

Cuffless Single-Site Photoplethysmography for Blood Pressure Monitoring.

J Clin Med 2020 Mar 7;9(3). Epub 2020 Mar 7.

Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.

One in three adults worldwide has hypertension, which is associated with significant morbidity and mortality. Consequently, there is a global demand for continuous and non-invasive blood pressure (BP) measurements that are convenient, easy to use, and more accurate than the currently available methods for detecting hypertension. This could easily be achieved through the integration of single-site photoplethysmography (PPG) readings into wearable devices, although improved reliability and an understanding of BP estimation accuracy are essential. This review paper focuses on understanding the features of PPG associated with BP and examines the development of this technology over the 2010-2019 period in terms of validation, sample size, diversity of subjects, and datasets used. Challenges and opportunities to move single-site PPG forward are also discussed.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3390/jcm9030723DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7141397PMC
March 2020

A Three-Dimensional Microelectrode Array to Generate Virtual Electrodes for Epiretinal Prosthesis Based on a Modeling Study.

Int J Neural Syst 2020 Mar;30(3):2050006

Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia.

Despite many advances in the development of retinal prostheses, clinical reports show that current retinal prosthesis subjects can only perceive prosthetic vision with poor visual acuity. A possible approach for improving visual acuity is to produce virtual electrodes (VEs) through electric field modulation. Generating controllable and localized VEs is a crucial factor in effectively improving the perceptive resolution of the retinal prostheses. In this paper, we aimed to design a microelectrode array (MEA) that can produce converged and controllable VEs by current steering stimulation strategies. Through computational modeling, we designed a three-dimensional concentric ring-disc MEA and evaluated its performance with different stimulation strategies. Our simulation results showed that electrode-retina distance (ERD) and inter-electrode distance (IED) can dramatically affect the distribution of electric field. Also the converged VEs could be produced when the parameters of the three-dimensional MEA were appropriately set. VE sites can be controlled by manipulating the proportion of current on each adjacent electrode in a current steering group (CSG). In addition, spatial localization of electrical stimulation can be greatly improved under quasi-monopolar (QMP) stimulation. This study may provide support for future application of VEs in epiretinal prosthesis for potentially increasing the visual acuity of prosthetic vision.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1142/S0129065720500069DOI Listing
March 2020

Recreation of eyelid mechanics using the sling concept.

J Plast Reconstr Aesthet Surg 2020 May 9;73(5):942-950. Epub 2020 Jan 9.

Faculty of Medicine, University of Sydney, Camperdown, New South Wales 2006, Australia; Department of Head and Neck Surgery, The Chris O'Brien Lifehouse, Camperdown, New South Wales 2050, Australia; Sydney Facial Nerve Service, The Chris O'Brien Lifehouse, Camperdown, New South Wales 2050, Australia; Central Clinical School, University of Sydney; Sydney, Camperdown, New South Wales 2050, Australia.

Background: Paralytic lagophthalmos causes major functional, aesthetic and psychological problems in patients with facial paralysis. The Bionic Lid Implant for Natural Closure (BLINC) project aims to restore eyelid function using an implanted electromagnetic actuator combined with an eyelid sling. The authors performed a preliminary study using cadaveric heads to investigate the optimal application of an eyelid sling in various configurations around the orbit.

Methods: The sling was tested in a cadaveric sheep head using 2 medial anchor points and 4 lateral ostectomy points. An impulse was generated using gravitational force to test each combination of medial and lateral sling insertion sites using weights between 10 and 50 g. Each generated blink was recorded and analysed. The final result was validated in a human cadaveric model.

Results: The maximum amount of eye closure and closure speed displayed in sheep were 83.7 ± 9.4% of total closure and 70.6 ± 6.9 mm/s at a maximum force of 490 mN, respectively. The 2 inferior lateral attachments performed better at displacing the eyelid than the superior attachments. The position with the highest degree of eye-closure (improvement of 21.6%, p < 0.001) and speed (improvement of 30.4 mm/s, p < 0.001) was the combination of a posterior medial attachment and an inferior-posterior lateral attachment, which resulted in a near physiological closure in human cadaver.

Conclusion: Closure improved with an inferior lateral position due to increased force acting in the direction of closure. Posterior positioning increases force acting radially, towards the centre of eyelid movement. The latter directs the closure force to effectively move the eyelid around the curved globe.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bjps.2019.12.007DOI Listing
May 2020

The eye and the chip 2019-Conference Report.

J Neural Eng 2020 01 22;17(1):010401. Epub 2020 Jan 22.

Department of Ophthalmology, Detroit Institute of Ophthalmology, Henry Ford Health System, Detroit, MI 48202, United States of America. Institute for Ophthalmic Research, Eberhard-Karls University, 72076 Tübingen, Germany. Author to whom any correspondence should be addressed.

View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1088/1741-2552/ab60c0DOI Listing
January 2020

Optimizing Stimulation Strategies for Retinal Electrical Stimulation: a Modelling Study.

Annu Int Conf IEEE Eng Med Biol Soc 2019 Jul;2019:2872-2875

In this research, a continuum multi-compartmental model of retinal electrical stimulation was utilized to find the best strategy for activating retinal ganglion cells (RGCs). Two types of return electrodes configuration placed suprachoroidally were used: monopolar and hexapolar. The current was delivered either simultaneously or sequentially with two kinds of waveforms: biphasic symmetric charge-balanced cathodic and anodic first pulses. Our results revealed there is no significant difference in current threshold between single monopolar and hexapolar stimulation regardless of the applied current stimulus waveform. Moreover, sequential stimulation for both monopolar or hexapolar was more effective in reducing current threshold than simultaneous stimulation when biphasic cathodic first pulses were used. Concurrent monopolar stimulation was significant in reducing the current threshold compared to single monopolar whereas concurrent hexapolar did not alter the current threshold. Overall, concurrent monopolar stimulation was efficacious in reducing current threshold regardless of the stimulus waveforms and sequential stimulation was more useful only with biphasic cathodic first pulses.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2019.8856918DOI Listing
July 2019

Predicting the outcome of transcatheter mitral valve implantation using image-based computational models.

J Cardiovasc Comput Tomogr 2020 Jul - Aug;14(4):335-342. Epub 2019 Nov 28.

Graduate School of Biomedical Engineering, UNSW, Sydney, Australia. Electronic address:

Background: The appropriate placement and size selection of mitral prostheses in transcatheter mitral valve implantation (TMVI) is critical, as encroachment on the left ventricular outflow tract (LVOT) may lead to flow obstruction. Recent advances in computed tomography (CT) can be employed for pre-procedural planning of mitral prosthetic valve placement. This study aims to develop patient-specific computational fluid dynamics models of the left ventricle (LV) in the presence of a mitral valve prosthesis to investigate blood flow and LVOT pressure gradient during systole.

Methods: Patient-specific computational fluid dynamics simulations of TMVI with varied cardiac anatomy and insertion angles were performed (n = 30). Wide-volume full cycle cardiovascular CT images prior to TMVI were used as source anatomical data (n = 6 patients). Blood movement was governed by Navier-Stokes equations and the LV endocardial wall deformation was derived from each patient's CT images.

Results: The computed pressure gradients in the presence of the mitral prosthesis compared well with clinically measured gradients. Analysis of the effects of prosthetic valve angulation, aorto-mitral annular angle, ejection fraction, LV size and new LVOT area (neo-LVOT) after TMVI in silico revealed that the neo-LVOT area (p < 0.001) was the most significant factor affecting LVOT pressure gradient. Angulation of the mitral valve can substantially mitigate LVOT gradient.

Conclusions: Computational fluid dynamics simulation is a promising method to aid in pre-TMVI planning and understanding the factors underlying LVOT obstruction.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcct.2019.11.016DOI Listing
September 2020

Multi-Site Photoplethysmography Technology for Blood Pressure Assessment: Challenges and Recommendations.

J Clin Med 2019 Nov 1;8(11). Epub 2019 Nov 1.

Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.

Hypertension is one of the most prevalent diseases and is often called the "silent killer" because there are usually no early symptoms. Hypertension is also associated with multiple morbidities, including chronic kidney disease and cardiovascular disease. Early detection and intervention are therefore important. The current routine method for diagnosing hypertension is done using a sphygmomanometer, which can only provide intermittent blood pressure readings and can be confounded by various factors, such as white coat hypertension, time of day, exercise, or stress. Consequently, there is an increasing need for a non-invasive, cuff-less, and continuous blood pressure monitoring device. Multi-site photoplethysmography (PPG) is a promising new technology that can measure a range of features of the pulse, including the pulse transit time of the arterial pulse wave, which can be used to continuously estimate arterial blood pressure. This is achieved by detecting the pulse wave at one body site location and measuring the time it takes for it to reach a second, distal location. The purpose of this review is to analyze the current research in multi-site PPG for blood pressure assessment and provide recommendations to guide future research. In a systematic search of the literature from January 2010 to January 2019, we found 13 papers that proposed novel methods using various two-channel PPG systems and signal processing techniques to acquire blood pressure using multi-site PPG that offered promising results. However, we also found a general lack of validation in terms of sample size and diversity of populations.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3390/jcm8111827DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6912608PMC
November 2019

Computational Simulation Expands Understanding of Electrotransfer-Based Gene Augmentation for Enhancement of Neural Interfaces.

Front Neurosci 2019 6;13:691. Epub 2019 Aug 6.

Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW, Australia.

The neural interface is a critical factor in governing efficient and safe charge transfer between a stimulating electrode and biological tissue. The interface plays a crucial role in the efficacy of electric stimulation in chronic implants and both electromechanical properties and biological properties shape this. In the case of cochlear implants, it has long been recognized that neurotrophins can stimulate growth of the target auditory nerve fibers into a favorable apposition with the electrode array, and recently such arrays have been re-purposed to enable electrotransfer (electroporation)-based neurotrophin gene augmentation to improve the "bionic ear." For both this acute bionic array-directed electroporation and for chronic conventional cochlear implant arrays, the electric fields generated in target tissue during pulse delivery are central to efficacy, but are challenging to map. We present a computational model for predicting electric fields generated by array-driven DNA electrotransfer in the cochlea. The anatomically realistic model geometry was reconstructed from magnetic resonance images of the guinea pig cochlea and an eight-channel electrode array embedded within this geometry. The model incorporates a description of both Faradaic and non-Faradaic mechanisms occurring at the electrode-electrolyte interface with frequency dependency optimized to match experimental impedance spectrometry measurements. Our simulations predict that a tandem electrode configuration with four ganged cathodes and four ganged anodes produces three to fourfold larger area in target tissue where the electric field is within the range for successful gene transfer compared to an alternate paired anode-cathode electrode configuration. These findings matched transfection efficacy of a green fluorescent protein (GFP) reporter following array-driven electrotransfer of the reporter-encoding plasmid DNA. This confirms utility of the developed model as a tool to optimize the safety and efficacy of electrotransfer protocols for delivery of neurotrophin growth factors, with the ultimate aim of using gene augmentation approaches to improve the characteristics of the electrode-neural interfaces in chronically implanted neurostimulation devices.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3389/fnins.2019.00691DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6691069PMC
August 2019

The use of photoplethysmography for assessing hypertension.

NPJ Digit Med 2019 26;2:60. Epub 2019 Jun 26.

1School of Electrical and Computer Engineering, University of British Columbia, Vancouver, Canada.

The measurement of blood pressure (BP) is critical to the treatment and management of many medical conditions. High blood pressure is associated with many chronic disease conditions, and is a major source of mortality and morbidity around the world. For outpatient care as well as general health monitoring, there is great interest in being able to accurately and frequently measure BP outside of a clinical setting, using mobile or wearable devices. One possible solution is photoplethysmography (PPG), which is most commonly used in pulse oximetry in clinical settings for measuring oxygen saturation. PPG technology is becoming more readily available, inexpensive, convenient, and easily integrated into portable devices. Recent advances include the development of smartphones and wearable devices that collect pulse oximeter signals. In this article, we review (i) the state-of-the-art and the literature related to PPG signals collected by pulse oximeters, (ii) various theoretical approaches that have been adopted in PPG BP measurement studies, and (iii) the potential of PPG measurement devices as a wearable application. Past studies on changes in PPG signals and BP are highlighted, and the correlation between PPG signals and BP are discussed. We also review the combined use of features extracted from PPG and other physiological signals in estimating BP. Although the technology is not yet mature, it is anticipated that in the near future, accurate, continuous BP measurements may be available from mobile and wearable devices given their vast potential.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41746-019-0136-7DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6594942PMC
June 2019

A Physiological Control System for an Implantable Heart Pump That Accommodates for Interpatient and Intrapatient Variations.

IEEE Trans Biomed Eng 2020 04 31;67(4):1167-1175. Epub 2019 Jul 31.

Left ventricular assist devices (LVADs) can provide mechanical support for a failing heart as a bridge to transplant and destination therapy. Physiological control systems for LVADs should be designed to respond to changes in hemodynamic across a variety of clinical scenarios and patients by automatically adjusting the heart pump speed. In this study, a novel adaptive physiological control system for an implantable heart pump was developed to respond to interpatient and intrapatient variations to maintain the left-ventricle-end-diastolic-pressure (LVEDP) in the normal range of 3 to 15 mmHg to prevent ventricle suction and pulmonary congestion. A new algorithm was also developed to detect LVEDP from pressure sensor measurement in real-time mode. Model-free adaptive control (MFAC) was employed to control the pump speed via simulation of 100 different patient conditions in each of six different patient scenarios, and compared to standard PID control. Controller performance was tracked using the sum of the absolute error (SAE) between the desired and measured LVEDP. The lower SAE on control tracking performance means that the measured LVEDP follows the desired LVEDP faster and with less amplitude oscillations, preventing ventricle suction and pulmonary congestion (mean and standard deviation of SAE (mmHg) for all 600 simulations were 18813 ± 29345 and 24794 ± 28380 corresponding to MFAC and PID controller, respectively). In four out of six patient scenarios, MFAC control tracking performance was better than the PID controller. This study shows the control performance can be guaranteed across different patients and conditions when using MFAC over PID control, which is a step toward clinical acceptance of these systems.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2019.2932233DOI Listing