Skin sodium is increased in male patients with multiple sclerosis and related animal models.

Proc Natl Acad Sci U S A 2021 Jul;118(28)

Department of Neurology, University Hospital Regensburg, 93053 Regensburg, Germany

Novel MRI techniques allow a noninvasive quantification of tissue sodium and reveal the skin as a prominent compartment of sodium storage in health and disease. Since multiple sclerosis (MS) immunopathology is initiated in the periphery and increased sodium concentrations induce proinflammatory immune cells, the skin represents a promising compartment linking high sodium concentrations and MS immunopathology. We used a 7-T sodium MRI (Na-MRI) and inductively coupled plasma mass spectrometry to investigate the skin sodium content in two mouse models of MS. We additionally performed 3-T Na-MRI of calf skin and muscles in 29 male relapsing-remitting MS (RRMS) patients and 29 matched healthy controls. Demographic and clinical information was collected from interviews, and disease activity was assessed by expanded disability status scale scoring. Na-MRI and chemical analysis demonstrated a significantly increased sodium content in the skin during experimental autoimmune encephalomyelitis independent of active immunization. In male patients with RRMS, Na-MRI demonstrated a higher sodium signal in the area of the skin compared to age- and biological sex-matched healthy controls with higher sodium, predicting future disease activity in cranial MRI. In both studies, the sodium enrichment was specific to the skin, as we found no alterations of sodium signals in the muscle or other tissues. Our data add to the recently identified importance of the skin as a storage compartment of sodium and may further represent an important organ for future investigations on salt as a proinflammatory agent driving autoimmune neuroinflammation such as that in MS.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1073/pnas.2102549118DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8285971PMC
July 2021

Cutting Staff Radiation Exposure and Improving Freedom of Motion during CT Interventions: Comparison of a Novel Workflow Utilizing a Radiation Protection Cabin versus Two Conventional Workflows.

Diagnostics (Basel) 2021 Jun 16;11(6). Epub 2021 Jun 16.

Department of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054 Erlangen, Germany.

This study aimed to evaluate the radiation exposure to the radiologist and the procedure time of prospectively matched CT interventions implementing three different workflows-the radiologist-(I) leaving the CT room during scanning; (II) wearing a lead apron and staying in the CT room; (III) staying in the CT room in a prototype radiation protection cabin without lead apron while utilizing a wireless remote control and a tablet. We prospectively evaluated the radiologist's radiation exposure utilizing an electronic personal dosimeter, the intervention time, and success in CT interventions matched to the three different workflows. We compared the interventional success, the patient's dose of the interventional scans in each workflow (total mAs and total DLP), the radiologist's personal dose (in µSV), and interventional time. To perform workflow III, a prototype of a radiation protection cabin, with 3 mm lead equivalent walls and a foot switch to operate the doors, was built in the CT examination room. Radiation exposure during the maximum tube output at 120 kV was measured by the local admission officials inside the cabin at the same level as in the technician's control room (below 0.5 μSv/h and 1 mSv/y). Further, to utilize the full potential of this novel workflow, a sterile packed remote control (to move the CT table and to trigger the radiation) and a sterile packed tablet anchored on the CT table (to plan and navigate during the CT intervention) were operated by the radiologist. There were 18 interventions performed in workflow I, 16 in workflow II, and 27 in workflow III. There were no significant differences in the intervention time (workflow I: 23 min ± 12, workflow II: 20 min ± 8, and workflow III: 21 min ± 10, = 0.71) and the patient's dose (total DLP, = 0.14). However, the personal dosimeter registered 0.17 ± 0.22 µSv for workflow II, while I and III both documented 0 µSv, displaying significant difference ( < 0.001). All workflows were performed completely and successfully in all cases. The new workflow has the potential to reduce interventional CT radiologists' radiation dose to zero while relieving them from working in a lead apron all day.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3390/diagnostics11061099DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8235446PMC
June 2021

Low-Field MRI-A New Generation of Breakthrough Technology in Clinical Imaging.

Invest Radiol 2021 Jun 16. Epub 2021 Jun 16.

From the Institute of Radiology, University Hospital of Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen Division of Medical Physics in Radiology German Cancer Research Center, Heidelberg, Germany.

Abstract: Magnetic resonance imaging (MRI) plays a pivotal role in diagnostic imaging. In today's clinical environment, scanners with field strengths of 1.5 to 3 T are most commonly used. However, recent technological advancements might help to augment the clinical usage and availability of MRI via the introduction of high-performance low-field MRI systems (ranging from ~0.1-0.55 T in current systems). The combination of low field strength and high-performance hardware is characterized by increased flexibility, excellent quality of results, and reduced cost. This review discusses the multifaceted potential advantages of a new generation of high-performance low-field MRI systems and presents the potential impact of such systems in terms of socioeconomic benefits as well as positive effects on patient care.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLI.0000000000000805DOI Listing
June 2021

Feasibility of deuterium magnetic resonance spectroscopy of 3-O-Methylglucose at 7 Tesla.

PLoS One 2021 7;16(6):e0252935. Epub 2021 Jun 7.

Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.

Deuterium Magnetic Resonance Spectroscopy (DMRS) is a non-invasive technique that allows the detection of deuterated compounds in vivo. DMRS has a large potential to analyze uptake, perfusion, washout or metabolism, since deuterium is a stable isotope and therefore does not decay during biologic processing of a deuterium labelled substance. Moreover, DMRS allows the distinction between different deuterated substances. In this work, we performed DMRS of deuterated 3-O-Methylglucose (OMG). OMG is a non-metabolizable glucose analog which is transported similar to D-glucose. DMRS of OMG was performed in phantom and in vivo measurements using a preclinical 7 Tesla MRI system. The chemical shift (3.51 ± 0.1 ppm) and relaxation times were determined. OMG was injected intravenously and spectra were acquired over a period of one hour to monitor the time evolution of the deuterium signal in tumor-bearing rats. The increase and washout of OMG could be observed. Three different exponential functions were compared in terms of how well they describe the OMG washout. A mono-exponential model with offset seems to describe the observed time course best with a time constant of 1910 ± 770 s and an offset of 2.5 ± 1.2 mmol/l (mean ± std, N = 3). Chemical shift imaging could be performed with a voxel size of 7.1 mm x 7.1 mm x 7.9 mm. The feasibility of DMRS with deuterium labelled OMG could be demonstrated. These data might serve as basis for future studies that aim to characterize glucose transport using DMRS.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0252935PLOS
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8184010PMC
June 2021

Detection of Microcalcifications in Spiral Breast Computed Tomography with Photon-Counting Detector Is Feasible: A Specimen Study.

Diagnostics (Basel) 2021 May 9;11(5). Epub 2021 May 9.

Department of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054 Erlangen, Germany.

The primary objective of the study was to compare a spiral breast computed tomography system (SBCT) to digital breast tomosynthesis (DBT) for the detection of microcalcifications (MCs) in breast specimens. The secondary objective was to compare various reconstruction modes in SBCT. In total, 54 breast biopsy specimens were examined with mammography as a standard reference, with DBT, and with a dedicated SBCT containing a photon-counting detector. Three different reconstruction modes were applied for SBCT datasets (Recon1 = voxel size (0.15 mm), smooth kernel; Recon2 = voxel size (0.05 mm), smooth kernel; Recon3 = voxel size (0.05 mm), sharp kernel). Sensitivity and specificity of DBT and SBCT for the detection of suspicious MCs were analyzed, and the McNemar test was used for comparisons. Diagnostic confidence of the two readers (Likert Scale 1 = not confident; 5 = completely confident) was analyzed with ANOVA. Regarding detection of MCs, reader 1 had a higher sensitivity for DBT (94.3%) and Recon2 (94.9%) compared to Recon1 (88.5%; < 0.05), while sensitivity for Recon3 was 92.4%. Respectively, reader 2 had a higher sensitivity for DBT (93.0%), Recon2 (92.4%), and Recon3 (93.0%) compared to Recon1 (86.0%; < 0.05). Specificities ranged from 84.7-94.9% for both readers ( > 0.05). The diagnostic confidence of reader 1 was better with SBCT than with DBT (DBT 4.48 ± 0.88, Recon1 4.77 ± 0.66, Recon2 4.89 ± 0.44, and Recon3 4.75 ± 0.72; DBT vs. Recon1/2/3: < 0.05), while reader 2 found no differences. Sensitivity and specificity for the detection of MCs in breast specimens is equal for DBT and SBCT when a small voxel size of (0.05 mm) is used with an equal or better diagnostic confidence for SBCT compared to DBT.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3390/diagnostics11050848DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8151348PMC
May 2021

Visualization of the epimysium and fascia thoracolumbalis at the lumbar spine using MRI.

Radiologe 2021 May 19. Epub 2021 May 19.

Radiologisches Institut, Universitätsklinikum Erlangen, Erlangen, Germany.

Background: The fascia thoracolumbalis (FTL) is an important component for stabilization and motion control of the lumbar spine. It coordinates the traction forces of the autochthonous muscles of the back (AM) and connects them to the muscles of the abdominal wall, shoulder, and buttocks.

Objectives: The aim of our study was to describe the assessment of the normal FTL and epimysium of the AM in MRI and to identify patterns associated with pathological changes in the lumbar spine.

Material And Methods: A total of 33 patients were retrospectively evaluated: 15 patients had no pathology at the lumbar spine; six patients had previous hemilaminectomy, three had spondylodesis, two had ventrolisthesis, and seven had scoliosis. The thickness of the FTL and EM was measured, and the adhesion of both structures was assessed.

Results: The fascial thickness at the levels of the lumbar vertebral bodies LVB 3 was 1.8, of LVB 4 it was 2.0, of LVB 5 it was 2.1, and at the sacral vertebra SVB 1 it was 1.8 mm. Fascial adhesions together with thickening of the EM occurred at the level of LVB 4 in 36% of the cases independently of the underlying disorder. Only thickening of the EM was seen in 48% of cases at the level of SVB 1. By contrast, adhesion of the FTL without epimysial changes occurred in 36% of cases at the level of LVB 3.

Conclusion: Thickening and adhesions at the EM and FTL occurred both postoperatively and in the case of scoliosis. Furthermore, lipomatous and muscular herniation could be detected in the FTL postoperatively. Epimysial and fascial alterations may be imaging manifestations of chronic myofascial back pain and should be included in radiological assessments.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00117-021-00849-9DOI Listing
May 2021

Tolvaptan treatment in an adult Fontan patient with protein-losing enteropathy: a serial Na-MRI investigation.

Ther Adv Chronic Dis 2021 16;12:20406223211004005. Epub 2021 Apr 16.

Department of Nephrology and Hypertension, Friedrich-Alexander University of Erlangen, Erlangen, Germany.

Background: Protein-losing enteropathy (PLE) is a severe complication of the univentricular Fontan circulation and associated with disturbances in salt and water homeostasis. Fontan patients with PLE have a poor prognosis, with increased morbidity and mortality. Due to limited therapeutic strategies, patients are often treated only symptomatically.

Methods: We report our first experience of Tolvaptan (TLV) treatment in a Fontan patient with PLE, severe volume retention and hyponatraemia, refractory to conventional diuretic therapy. In addition to clinical parameters, we monitored drug effects including tissue sodium and volume status serial Na-magnetic resonance imaging (Na-MRI) and bioimpedance spectroscopy compared with age-matched controls.

Results: Na-MRI identified elevated tissue sodium, which decreased under TLV treatment, as well as volume status, while serum sodium increased and the patient's symptoms improved. During long-term treatment, we were able to differentiate between sodium and volume status in our patient, suggesting that TLV uncoupled body sodium from water.

Conclusion: TLV in addition to loop diuretics improved clinical symptoms of PLE and lowered tissue sodium overload. Long-term effects should be further evaluated in Fontan patients.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1177/20406223211004005DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8053834PMC
April 2021

Multi-Parametric Analysis of Below-Knee Compression Garments on Delayed-Onset Muscle Soreness.

Int J Environ Res Public Health 2021 04 6;18(7). Epub 2021 Apr 6.

Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Maximiliansplatz 3, 91054 Erlangen, Germany.

To investigate below-knee compression garments during exercise and a post-exercise period of 6 h on clinical, functional, and morphological outcomes in delayed-onset muscle soreness (DOMS). Eighteen volunteers (age: 24.1 ± 3.6, BMI 22.7 ± 2.7 kg/m) were enrolled. Measures were acquired at baseline, 6 h, and 48 h after eccentric and plyometric exercise, with wearing a compression garment (21-22 mmHg) on a calf during and for the first 6 h after exercise. 3T MRI was performed for quantification of intramuscular edema (T2 signal intensity (SI), T2 time, and manual volume segmentation); jump height, calf circumference, ankle dorsiflexion (DF), creatine kinase (CK), and muscle soreness were assessed. DOMS was confirmed in all participants after 48 h, with an increase in soreness ( < 0.001) and CK ( = 0.001), decrease in jump height ( < 0.01), and the presence of intramuscular edema ( < 0.01) in both the compressed and non-compressed limbs. No differences between the compressed and non-compressed limbs were observed for muscle soreness and jump height. MRI T2 SI, T2 time, soreness, and manual segmentation revealed no effect of the compression treatment. The assessment of calf circumference and DF showed no changes in either the compression or non-compression limb ( = 1.0). Wearing compression garments during combined eccentric and plyometric exercise and for 6 h post-exercise has no effect on clinical signs of DOMS, jump performance, or the development of intramuscular edema.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3390/ijerph18073798DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8038710PMC
April 2021

Resolution of vascular inflammation in patients with new-onset giant cell arteritis: data from the RIGA study.

Rheumatology (Oxford) 2021 Apr 8. Epub 2021 Apr 8.

Rheumatology Unit, Azienda Unità Sanitaria Locale-IRCCS di Reggio Emilia, Italy.

Objectives: Efficacy evaluation of giant cell arteritis (GCA) treatment is primarily based on non-specific symptoms and laboratory markers. We aimed to assess the change in vascular inflammation in patients with large vessel (LV)-GCA under different treatments using [18F]FDG PET/CT.

Methods: Observational study on patients with new-onset, active LV-GCA starting treatment with either prednisolone monotherapy (PRED) or combination with methotrexate (MTX) or tocilizumab (TOC). All patients underwent baseline and follow-up PET/CT. The aorta and its major branches were assessed using PET vascular activity score (PETVAS) by independent readers. Cumulative glucocorticoid doses and cessation of glucocorticoid treatment were documented in all patients.

Results: We included 88 LV-GCA patients, 27 were treated with PRED, 42 with MTX, and 19 with TOC. PETVAS decreased from 18.9-8.0 units at follow-up in the overall population (p< 0.001). PETVAS changes were numerically higher in patients receiving MTX (-12.3 units) or TOC (-11.7 units) compared with PRED (-8.7). Mean cumulative prednisolone dosages were 5637, 4418, and 2984 mg in patients treated with PRED, MTX, and TOC (p= 0.002). Risk ratios for glucocorticoid discontinuation at the time of follow-up PET/CT were 6.77 (95%CI 1.01-45.29; p= 0.049) and 16.25 (95%CI 2.60-101.73; p= 0.003) for MTX and TOC users compared with PRED users.

Conclusion: Treatment of LV-GCA inhibits vascular inflammation in the aorta and its major branches. While similar control of vascular inflammation was achieved with PRED, MTX, and TOC treatments, TOC showed a strong glucocorticoid sparing effect, supporting the concept of initial combination therapy.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1093/rheumatology/keab332DOI Listing
April 2021

Image Quality and Detection of Small Focal Liver Lesions in Diffusion-Weighted Imaging: Comparison of Navigator Tracking and Free-Breathing Acquisition.

Invest Radiol 2021 Mar 12. Epub 2021 Mar 12.

From the Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen Department of Radiology, Klinikum Forchheim-Fränkische Schweiz GmbH, Forchheim, Germany.

Objectives: The aim of this study was to compare intraindividual diffusion-weighted imaging (DWI) of the liver acquired with free breathing (FB) versus navigator triggering (NT) for assessing small focal liver lesions (FLLs) in noncirrhotic patients.

Materials And Methods: Patients with known or suspected multiple FLLs were prospectively included, and spin-echo echo-planar DWI with NT and FB acquisition was performed (b-values, 50 and 800 s/mm2 [b50 and b800]). NT and FB DWI sequences with similar acquisitions times were used. Liver and lesion signal-to-noise ratios were measured at b800. The DWI scans were analyzed independently by 2 readers. Liver edge delineation, presence of stair-step artifacts, vessel sharpness, severity of cardiac motion artifacts, overall image quality, and lesion conspicuity were rated with 5-point Likert scales. Small and large FLLs (ie, <1 cm or ≥1 cm) were rated separately for lesion conspicuity. The FLL detectability was estimated by comparing the number of lesions visible with FB to those visible with NT.

Results: Forty-three patients were included in the study. The FB acquisition performed better in terms of severity of cardiac motion artifacts. The NT performed better in terms of liver edge delineation and vessel sharpness. Little difference was found for stair-step artifact, overall image quality, and conspicuity of large FLL, whereas the conspicuity of small FLL was better for NT. For small FLL, both readers found more lesions with NT in 11 cases at b800. For large FLL, this effect was much less pronounced (1 case at b800 reported by 1 of the readers). The mean liver and lesion signal-to-noise ratios were 16.8/41.5 and 19.8/38.4 for NT/FB, respectively.

Conclusions: Small FLL detection is better with NT. Large FLL detection by FB and NT is similarly good. We conclude that NT should be used.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLI.0000000000000776DOI Listing
March 2021

Brain tissues have single-voxel signatures in multi-spectral MRI.

Neuroimage 2021 07 20;234:117986. Epub 2021 Mar 20.

Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.

Since the seminal works by Brodmann and contemporaries, it is well-known that different brain regions exhibit unique cytoarchitectonic and myeloarchitectonic features. Transferring the approach of classifying brain tissues - and other tissues - based on their intrinsic features to the realm of magnetic resonance (MR) is a longstanding endeavor. In the 1990s, atlas-based segmentation replaced earlier multi-spectral classification approaches because of the large overlap between the class distributions. Here, we explored the feasibility of performing global brain classification based on intrinsic MR features, and used several technological advances: ultra-high field MRI, q-space trajectory diffusion imaging revealing voxel-intrinsic diffusion properties, chemical exchange saturation transfer and semi-solid magnetization transfer imaging as a marker of myelination and neurochemistry, and current neural network architectures to analyze the data. In particular, we used the raw image data as well to increase the number of input features. We found that a global brain classification of roughly 97 brain regions was feasible with gross classification accuracy of 60%; and that mapping from voxel-intrinsic MR data to the brain region to which the data belongs is possible. This indicates the presence of unique MR signals of different brain regions, similar to their cytoarchitectonic and myeloarchitectonic fingerprints.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neuroimage.2021.117986DOI Listing
July 2021

An A.I. classifier derived from 4D radiomics of dynamic contrast-enhanced breast MRI data: potential to avoid unnecessary breast biopsies.

Eur Radiol 2021 Aug 20;31(8):5866-5876. Epub 2021 Mar 20.

Department of Biomedical Imaging and Image Guided Therapy, Medical University of Vienna, Waehringerguertel 18-20, 1090, Vienna, Austria.

Objectives: Due to its high sensitivity, DCE MRI of the breast (bMRI) is increasingly used for both screening and assessment purposes. The high number of detected lesions poses a significant logistic challenge in clinical practice. The aim was to evaluate a temporally and spatially resolved (4D) radiomics approach to distinguish benign from malignant enhancing breast lesions and thereby avoid unnecessary biopsies.

Methods: This retrospective study included consecutive patients with MRI-suspicious findings (BI-RADS 4/5). Two blinded readers analyzed DCE images using a commercially available software, automatically extracting BI-RADS curve types and pharmacokinetic enhancement features. After principal component analysis (PCA), a neural network-derived A.I. classifier to discriminate benign from malignant lesions was constructed and tested using a random split simple approach. The rate of avoidable biopsies was evaluated at exploratory cutoffs (C, 100%, and C, ≥ 95% sensitivity).

Results: Four hundred seventy (295 malignant) lesions in 329 female patients (mean age 55.1 years, range 18-85 years) were examined. Eighty-six DCE features were extracted based on automated volumetric lesion analysis. Five independent component features were extracted using PCA. The A.I. classifier achieved a significant (p < .001) accuracy to distinguish benign from malignant lesion within the test sample (AUC: 83.5%; 95% CI: 76.8-89.0%). Applying identified cutoffs on testing data not included in training dataset showed the potential to lower the number of unnecessary biopsies of benign lesions by 14.5% (C) and 36.2% (C).

Conclusion: The investigated automated 4D radiomics approach resulted in an accurate A.I. classifier able to distinguish between benign and malignant lesions. Its application could have avoided unnecessary biopsies.

Key Points: • Principal component analysis of the extracted volumetric and temporally resolved (4D) DCE markers favored pharmacokinetic modeling derived features. • An A.I. classifier based on 86 extracted DCE features achieved a good to excellent diagnostic performance as measured by the area under the ROC curve with 80.6% (training dataset) and 83.5% (testing dataset). • Testing the resulting A.I. classifier showed the potential to lower the number of unnecessary biopsies of benign breast lesions by up to 36.2%, p < .001 at the cost of up to 4.5% (n = 4) false negative low-risk cancers.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-021-07787-zDOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8270804PMC
August 2021

Detection of Changes in Renal Blood Flow Using Arterial Spin Labeling MRI.

Am J Nephrol 2021 5;52(1):69-75. Epub 2021 Mar 5.

Department of Nephrology and Hypertension, University Hospital Erlangen, Erlangen, Germany,

Background: Alteration in kidney perfusion is an early marker of renal damage. The purpose of this study was to evaluate if changes in renal blood flow (RBF) could be detected using MRI with arterial spin labeling (ASL) technique.

Methods: RBF as assessed by cortical (CRBF), medullary, and total renal blood flow (TRBF) were measured by MRI with arterial spin labeling (ASL-MRI) using flow-sensitive alternating inversion recovery true fast imaging with steady-state precession sequence. In 11 normotensive healthy individuals (NT) and 11 hypertensive patients (HT), RBF was measured at baseline and after both feet were covered with cold ice packs (cold pressor test) that activates the sympathetic nervous system. In another experiment, RBF was measured in 10 patients with CKD before and after a pharmacological intervention. We compared RBF measurements between the 3 study populations.

Results: A significant reduction in CRBF (p = 0.042) and a trend in TRBF (p = 0.053) were observed in response to the activation of the sympathetic nervous system. A trend toward reduction of CRBF (p = 0.051) and TRBF (p = 0.059) has been detected after pharmacological intervention. TRBF was significantly lower in patients with HT and CKD patients compared to NT individuals (NT vs. HT, p = 0.014; NT vs. CKD, p = 0.004). TRBF was lower in patients with CKD compared to HT (p = 0.047).

Conclusion: Our data indicate that both acute and short-term changes in RBF could be detected using ASL-MRI. We were able to detect differences in RBF between healthy and diseased individuals by needing only small sample size per group. Thus, ASL-MRI offers an advantage in conducting clinical trials compared to other technologies.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1159/000513665DOI Listing
March 2021

Identification of anatomic risk factors for scalar translocation in cochlear implant patients.

Z Med Phys 2021 Feb 26. Epub 2021 Feb 26.

Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Erlangen, Waldstraße 1, 91054, Erlangen, Germany.

Aim: Microanatomical evaluation of cochlear implant (CI) patients to identify anatomical risk factors for a scalar translocation.

Methods: CI patients with both a regular scala tympani spiralization (group A) and a scalar translocation (group B) were identified via postoperative flat-detector computed tomography (FD-CT). Then, the corresponding preoperative multislice computed tomography (MS-CT) and postoperative FD-CT datasets were assessed: First, the cochleae were separated in 6 segments of 45° each. Next, quantitative (cochlea height, length, depth, cochlear duct diameter [CD] per segment; percentual tapering of the CD per segment named cochlear geometry index [CGI]) and qualitative (identifiability of the CI model; CI-integrity; intracochlear array position) parameters were evaluated and compared for both groups. Receiver-operating-characteristics (ROC) analysis was performed for the CGI.

Results: In total, 40 preoperative MS-CT and postoperative FD-CT datasets (n=20; n=20) were analysed. Model "CI 512" was successfully identified and CI-integrity has been confirmed in all cases. Quantitative analysis showed a significant difference of both the CD at 0° (CD= 2.06± 0.23mm; CD= 2.19±0.18mm; p= 0.04) and the CGI of the first segment (CGI= 18.87±6.04%; CGI= 28.89±8.58%; p= 0.0001). For all other 5 cochlear segments there was no significant difference of CD and CGI; there was no significant difference of external cochlea diameters. The area under the curve (AUC) of the CGI was 0.864 with 24.50° as the optimal cut-off value to discriminate patients with a scala tympani spiralization and a scalar translocation. CGI of> 24.50° allowed the correct identification of 85% of patients with a scalar translocation.

Conclusion: CI insertion trauma is associated with a significantly higher narrowing of the proximal basal cochlea turn (BCT). The CGI as percentual tapering of the BCT turned out as reliable, clinically applicable parameter for identification of patients with an increased risk for a scalar translocation.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.zemedi.2021.01.009DOI Listing
February 2021

Whole-brain quantitative CEST MRI at 7T using parallel transmission methods and correction.

Magn Reson Med 2021 07 26;86(1):346-362. Epub 2021 Feb 26.

Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.

Purpose: To enable whole-brain quantitative CEST MRI at ultra-high magnetic field strengths (B ≥ 7T) within short acquisition times.

Methods: Multiple interleaved mode saturation (MIMOSA) was combined with fast online-customized (FOCUS) parallel transmission (pTx) excitation pulses and correction to achieve homogenous whole-brain coverage. Examinations of 13 volunteers were performed on a 7T MRI system with 3 different types of pulse sequences: (1) saturation in circular polarized (CP) mode and CP mode readout, (2) MIMOSA and CP readout, and (3) MIMOSA and FOCUS readout. For comparison, the inverse magnetic transfer ratio metric for relayed nuclear Overhauser effect and amide proton transfer were calculated. To investigate the number of required acquisitions for a good correction, 4 volunteers were measured with 6 different B amplitudes. Finally, time point repeatability was investigated for 6 volunteers.

Results: MIMOSA FOCUS sequence using correction, with both single and multiple points, reduced inhomogeneity of the CEST contrasts around the occipital lobe and cerebellum. Results indicate that the most stable inter-subject coefficient of variation was achieved using the MIMOSA FOCUS sequence. Time point repeatability of MIMOSA FOCUS with single-point correction showed a maximum coefficient of variation below 8% for 3 measurements in a single volunteer.

Conclusion: A combination of MIMOSA FOCUS with a single-point correction can be used to achieve quantitative CEST measurements at ultra-high magnetic field strengths. Compared to previous correction methods, acquisition time can be reduced as additional scans required for correction can be omitted.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.28745DOI Listing
July 2021

Cinematic Rendering in Mixed-Reality Holograms: A New 3D Preoperative Planning Tool in Pediatric Heart Surgery.

Front Cardiovasc Med 2021 9;8:633611. Epub 2021 Feb 9.

Department of Pediatric Cardiology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany.

Cinematic rendering (CR) is based on a new algorithm that creates a photo-realistic three-dimensional (3D) picture from cross-sectional images. Previous studies have shown its positive impact on preoperative planning. To date, CR presentation has only been possible on 2D screens which limited natural 3D perception. To depict CR-hearts spatially, we used mixed-reality technology and mapped corresponding hearts as holograms in 3D space. Our aim was to assess the benefits of CR-holograms in the preoperative planning of cardiac surgery. Including 3D prints allowed a direct comparison of two spatially resolved display methods. Twenty-six patients were recruited between February and September 2019. CT or MRI was used to visualize the patient's heart preoperatively. The surgeon was shown the anatomy in cross-sections on a 2D screen, followed by spatial representations as a 3D print and as a high-resolution hologram. The holographic representation was carried out using mixed-reality glasses (HoloLens®). To create the 3D prints, corresponding structures were segmented to create STL files which were printed out of resin. In 22 questions, divided in 5 categories (3D-imaging effect, representation of pathology, structure resolution, cost/benefit ratio, influence on surgery), the surgeons compared each spatial representation with the 2D method, using a five-level Likert scale. The surgical preparation time was assessed by comparing retrospectively matched patient pairs, using a paired -test. CR-holograms surpassed 2D-monitor imaging in all categories. CR-holograms were superior to 3D prints in all categories (mean Likert scale 4.4 ± 1.0 vs. 3.7 ± 1.3, < 0.05). Compared to 3D prints it especially improved the depth perception (4.7 ± 0.7 vs. 3.7 ± 1.2) and the representation of the pathology (4.4 ± 0.9 vs. 3.6 ± 1.2). 3D imaging reduced the intraoperative preparation time ( = 24, 59 ± 23 min vs. 73 ± 43 min, < 0.05). In conclusion, the combination of an extremely photo-realistic presentation via cinematic rendering and the spatial presentation in 3D space via mixed-reality technology allows a previously unattained level of comprehension of anatomy and pathology in preoperative planning.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3389/fcvm.2021.633611DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7900175PMC
February 2021

Effect of compression garments on muscle perfusion in delayed-onset muscle soreness: A quantitative analysis using intravoxel incoherent motion MR perfusion imaging.

NMR Biomed 2021 Jun 16;34(6):e4487. Epub 2021 Feb 16.

Institute of Radiology, University Hospital Erlangen, Erlangen, Germany.

The aim of this prospective cohort study was to evaluate the effect of compression garments under resting conditions and after the induction of delayed-onset muscle soreness (DOMS) by MR perfusion imaging using intravoxel incoherent motion (IVIM). Magnetic resonance imaging of both lower legs of 16 volunteers was performed before and after standardized eccentric exercises that induced DOMS. A compression garment (21-22 mmHg) was worn during and for 6 h after exercise on one randomly selected leg. IVIM MR imaging, represented as total muscle perfusion D*f, perfusion fraction f and tissue diffusivity D, were compared between baseline and directly, 30 min, 6 h and 48 h after exhausting exercise with and without compression. Creatine kinase levels and T2-weighted images were acquired at baseline and after 48 h. DOMS was induced in the medial head of the gastrocnemius muscle (MGM) in all volunteers. Compression garments did not show any significant effect on IVIM perfusion parameters at any time point in the MGM or the tibialis anterior muscle (p > 0.05). Microvascular perfusion in the MGM increased significantly in both the compressed and noncompressed leg between baseline measurements and those taken directly after and 30 min after the exercise: the relative median f increased by 31.5% and 24.7% in the compressed and noncompressed leg, respectively, directly after the exercise compared with the baseline value. No significant change in tissue perfusion occurred 48 h after the induction of DOMS compared with baseline. It was concluded that compression garments (21-22 mmHg) do not alter microvascular muscle perfusion at rest, nor do they have any significant effect during the regeneration phase of DOMS. In DOMS, only a short-term effect of increased muscle perfusion (30 min after exercise) was observed, with normalization occurring during regeneration after 6-48 h. The normalization of perfusion independently of compression after 6 h may have implications for diagnostic and therapeutic strategies and for the better understanding of pathophysiological pathways in DOMS.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1002/nbm.4487DOI Listing
June 2021

Potential for Radiation Dose Reduction in Dual-Source Computed Tomography of the Lung in the Pediatric and Adolescent Population Compared to Digital Radiography.

Diagnostics (Basel) 2021 Feb 10;11(2). Epub 2021 Feb 10.

Department of Radiology, University Hospital Erlangen, 91054 Erlangen, Germany.

Low-dose dual-source computed tomography (DSCT) protocols for the evaluation of lung diseases in children and adolescents are of importance since this age group is particularly prone to radiation damage. The aim of this study was to evaluate image quality of low-dose DSCT of the lung and to assess the potential of radiation dose reduction compared to digital radiographs (DR). Three groups, each consisting of 19 patients, were examined with different DSCT protocols using tin prefiltration (Sn96/64/32 ref. mAs at 100 kV). Different strengths of iterative reconstruction were applied (ADMIRE 2/3/4). DSCT groups were compared to 19 matched patients examined with posterior-anterior DR. Diagnostic confidence, detectability of anatomical structures and small lung lesions were evaluated on a 4-point Likert scale (LS 1 = unacceptable, 4 = fully acceptable; a value ≥ 3 was considered acceptable). Effective dose (ED) was 31-/21-/9-fold higher in Sn96/Sn64/Sn32 compared to DR. Diagnostic confidence was sufficient in Sn96/Sn64 (LS 3.4/3.2), reduced in Sn32 (LS 2.7) and the worst in DR (LS 2.4). In DSCT, detectability of small anatomical structures was always superior to DR ( < 0.05). Mean lesion size ranged from 5.1-7 mm; detectability was acceptable in all DSCT groups (LS 3.0-3.4) and superior to DR (LS 1.9; < 0.05). Substantial dose lowering in DSCT of the pediatric lung enables acceptable detectability of small lung lesions with a radiation dose being about 10-fold higher compared to DR.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3390/diagnostics11020270DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7916398PMC
February 2021

Scanned versus Fused-Reconstructed Oblique MR-Images for Assessment of the Tibiofibular Syndesmosis-Diagnostic PerFormance and Reader Agreement.

Diagnostics (Basel) 2021 Jan 29;11(2). Epub 2021 Jan 29.

Department of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054 Erlangen, Germany.

To evaluate the diagnostic performance and reader agreement of a novel MRI image fusion method enabling the reconstruction of oblique images for the assessment of the tibiofibular syndesmosis. We evaluated 40 magnetic resonance imaging examinations of patients with ankle sprains (16 with ruptures and 24 without) for the presence of anteroinferior tibiofibular ligament rupture. For all patients, we performed a fusion of standard two-dimensional transversal and coronal 3 mm PDw TSE images into an oblique-fusion reconstruction (OFR) and compared these against conventionally scanned oblique sequence for the evaluation of the tibiofibular syndesmosis. To evaluate diagnostic performance, two expert readers independently read the OFR images twice. We analyzed sensitivity, specificity, negative and positive predictive values, accuracy, and agreement. Reader 1 misinterpreted one OFR as a false negative, demonstrating a sensitivity of 0.94 and specificity of 1.00, reader 2 demonstrated perfect accuracy. Intrareader agreement was almost perfect for reader 1 (α = 0.95) and was perfect for reader 2 (α = 1.00). Additionally, interreader agreement between all fusion sequence reads was almost perfect (α = 0.97). The proposed OFR enables reliable detection of anteroinferior tibiofibular ligament rupture with excellent inter- and intrareader agreement, making conventional scanning of oblique images redundant and supplies a method to retroactively create oblique images, e.g., from external examinations.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3390/diagnostics11020197DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7910886PMC
January 2021

Effects of 16 months of high intensity resistance training on thigh muscle fat infiltration in elderly men with osteosarcopenia.

Geroscience 2021 04 15;43(2):607-617. Epub 2021 Jan 15.

Department of Medicine III, Friedrich-Alexander University of Erlangen-Nürnberg, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany.

Osteosarcopenia is characterized by a progressive decline in muscle function and bone strength and associated with muscle fat accumulation. This study aimed to determine the effect of long-term high intensity resistance training (HIRT) on thigh muscle fat infiltration in older men with osteosarcopenia. Forty-three community-dwelling men (72 years and older) were randomly assigned to either an exercise group (EG, n = 21) or an inactive control group (CG, n = 22). EG participants performed a supervised single-set exercise training with high effort two times per week. Participants of both groups were individually provided with dietary protein to reach a cumulative intake of 1.5-1.6 g/kg/day or 1.2-1.3 g/kg/day (EG/CG), respectively, and Up to 10,000 IE/week of Vitamin-D were supplemented in participants with 25 OH Vitamin-D 3 levels below 100 nmol/l. Magnetic resonance (MR) imaging was performed to determine muscle and adipose tissue volume and fat fraction of the thigh. At baseline, there were no significant differences between the two groups. After 16 month,, there were significant training effects of 15% (p = 0.004) on intermuscular adipose tissue (IMAT) volume, which increased in the CG (p = 0.012) and was stable in the EG. In parallel, fat fraction within the deep fascia of the thigh (Baseline, EG: 18.2 vs CG: 15.5, p = 0.16) significantly differed between the groups (Changes, EG: 0.77% vs. CG: 7.7%, p = 0.009). The study confirms the role of fat infiltration of the muscles as an advanced imaging marker in osteosarcopenia and the favorable effects of HIRT on adipose tissue volume of the thigh, in men with osteosarcopenia.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11357-020-00316-8DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8110662PMC
April 2021

Bone Structure Analysis of the Radius Using Ultrahigh Field (7T) MRI: Relevance of Technical Parameters and Comparison with 3T MRI and Radiography.

Diagnostics (Basel) 2021 Jan 12;11(1). Epub 2021 Jan 12.

Department of Radiology, Friedrich Alexander University Erlangen-Nürnberg (FAU) & Universitätsklinikum Erlangen, 91054 Erlangen, Germany.

Bone fractal signature analysis (FSA-also termed bone texture analysis) is a tool that assesses structural changes that may relate to clinical outcomes and functions. Our aim was to compare bone texture analysis of the distal radius in patients and volunteers using radiography and 3T and 7T magnetic resonance imaging (MRI)-a patient group ( = 25) and a volunteer group ( = 25) were included. Participants in the patient group had a history of chronic wrist pain with suspected or confirmed osteoarthritis and/or ligament instability. All participants had 3T and 7T MRI including T1-weighted turbo spin echo (TSE) sequences. The 7T MRI examination included an additional high-resolution (HR) T1 TSE sequence. Radiographs of the wrist were acquired for the patient group. When comparing patients and volunteers (unadjusted for gender and age), we found a statistically significant difference of horizontal and vertical fractal dimensions (FDs) using 7T T1 TSE-HR images in low-resolution mode (horizontal: = 0.04, vertical: = 0.01). When comparing radiography to the different MRI sequences, we found a statistically significant difference for low- and high-resolution horizontal FDs between radiography and 3T T1 TSE and 7T T1 TSE-HR. Vertical FDs were significantly different only between radiographs and 3T T1 TSE in the high-resolution mode; FSA measures obtained from 3T and 7T MRI are highly dependent on the sequence and reconstruction resolution used, and thus are not easily comparable between MRI systems and applied sequences.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3390/diagnostics11010110DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7826934PMC
January 2021

Fast online-customized (FOCUS) parallel transmission pulses: A combination of universal pulses and individual optimization.

Magn Reson Med 2021 06 5;85(6):3140-3153. Epub 2021 Jan 5.

Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.

Purpose: To mitigate spatial flip angle (FA) variations under strict specific absorption rate (SAR) constraints for ultra-high field MRI using a combination of universal parallel transmit (pTx) pulses and fast subject-specific optimization.

Methods: Data sets consisting of B , maps, and virtual observation point (VOP) data were acquired from 72 subjects (study groups of 48/12 healthy Europeans/Asians and 12 Europeans with pathological or incidental findings) using an 8Tx/32Rx head coil on a 7T whole-body MR system. Combined optimization values (COV) were defined as combination of spiral-nonselective (SPINS) trajectory parameters and an energy regularization weight. A set of COV was optimized universally by simulating the individual RF pulse optimizations of 12 training data sets (healthy Europeans). Subsequently, corresponding universal pulses (UPs) were calculated. Using COV and UPs, individually optimized pulses (IOPs) were calculated during the sequence preparation phase (maximum 15 s). Two different UPs and IOPs were evaluated by calculating their normalized root-mean-square error (NRMSE) of the FA and SAR in simulations of all data sets. Seven additional subjects were examined using an MPRAGE sequence that uses the designed pTx excitation pulses and a conventional adiabatic inversion.

Results: All pTx pulses resulted in decreased mean NRMSE compared to a circularly polarized (CP) pulse (CP = ~28%, UPs = ~17%, and IOPs = ~12%). UPs and IOPs improved homogeneity for all subjects. Differences in NRMSE between study groups were much lower than differences between different pulse types.

Conclusion: UPs can be used to generate fast online-customized (FOCUS) pulses gaining lower NRMSE and/or lower SAR values.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.28643DOI Listing
June 2021

Gadolinium-based contrast agents: What we learned from acute adverse events, nephrogenic systemic fibrosis and brain retention.

Rofo 2020 Dec 21. Epub 2020 Dec 21.

Institute of Radiology, University Medical Center, Erlangen, Germany.

Background:  Radiologists have been administering gadolinium-based contrast agents (GBCA) in magnetic resonance imaging for several decades, so that there is abundant experience with these agents regarding allergic-like reactions, nephrogenic systemic fibrosis (NSF) and gadolinium retention in the brain.

Methods:  This review is based on a selective literature search and reflects the current state of research on acute adverse effects of GBCA, NSF and brain retention of gadolinium.

Results:  Due to the frequent use of GBCA, data on adverse effects of these compounds are available in large collectives. Allergic-like reactions occurred rarely, whereas severe acute reactions were very rarely observed. Systemic changes in NSF also occur very rarely, although measures to avoid NSF resulted in a significantly reduced incidence of NSF. Due to gadolinium retention in the body after administration of linear MR contrast agents, only macrocyclic preparations are currently used with few exceptions. Clear clinical correlates of gadolinium retention in the brain could not be identified so far. Although the clinical added value of GBCA is undisputed, individual risks associated with the injection of GBCA should be identified and the use of non-contrast enhanced MR techniques should be considered. Alternative contrast agents such as iron oxide nanoparticles are not clinically approved, but are currently undergoing clinical trials.

Conclusion:  GBCA have a very good risk profile with a low rate of adverse effects or systemic manifestations such as NSF. Gadolinium retention in the brain can be minimized by the use of macrocyclic GBCA, although clear clinical correlates due to gadolinium retention in the brain following administration of linear GBCA could not be identified yet.

Key Points: · Acute adverse effects are predominantly mild/moderate, rarely severe reactions occur.. · International guidelines resulted in significant reduction of nephrogenic systemic fibrosis.. · Application of macrocyclic contrast agents minimizes gadolinium retention in the brain..

Citation Format: · Bäuerle T, Saake M, Uder M. Gadolinium-based contrast agents: What we learned from acute adverse events, nephrogenic systemic fibrosis and brain retention. Fortschr Röntgenstr 2020; DOI: 10.1055/a-1328-3177.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1055/a-1328-3177DOI Listing
December 2020

Morphological, functional, and molecular assessment of breast cancer bone metastases by experimental ultrasound techniques compared with magnetic resonance imaging and histological analysis.

Bone 2021 03 19;144:115821. Epub 2020 Dec 19.

Institute of Radiology, University Hospital, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054 Erlangen, Germany. Electronic address:

Background: The imaging of bone metastases, which is regularly performed by cross-sectional modalities, is clinically vital when characterizing and staging osseous lesions. In this paper, we aimed to establish a novel methodology using experimental ultrasound (US) techniques to assess the morphological, functional, and molecular features of breast cancer bone metastases in an animal model, compared with magnetic resonance imaging (MRI) and histological analysis.

Materials And Methods: Nude rats were implanted intra-arterially with MDA-MB-231 breast cancer cells to induce osteolytic metastasis in their right hind legs. Once tumors had developed, an experimental US technique using automatic 3D scanning and MRI were performed. For assessment of perfusion, functional imaging techniques included contrast-enhanced US (CEUS) and dynamic contrast-enhanced MRI (DCE-MRI). For molecular ultrasound, anti-VEGFR2 conjugated microbubbles were applied and correlated with immunostaining for VEGFR2 expression.

Results: 3D US enabled the automatic assessment of osteolytic lesions, including the largest tumor diameters along the x-, y- and z-axes as well as the segmented tumor volumes, without significant differences between US and MRI (p > 0.18). The CEUS and DCE-MRI of osseous lesions showed corresponding results for the parameters peak enhancement, wash-in area under the curve (both, r > 0.5) and wash-in perfusion index (r > 0.3) when differentiating between tumor, necrotic tissue and healthy muscle tissue (all, p < 0.01). Finally, molecular US allowed the non-invasive assessment of increased VEGFR2 expression in skeletal lesions compared with surrounding muscle tissue (p = 0.03), while a control antibody could not discriminate between these tissues (p = 0.44)-a factor which was confirmed by histological analysis.

Conclusion: To the best of our knowledge, this is the first report on an imaging protocol for breast cancer bone metastasis using an experimental US scanner. Therefore, we present a novel methodology to characterize these osseous lesions on the morphological, functional, and molecular level in correlation with MRI and histological analysis.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bone.2020.115821DOI Listing
March 2021

[Diagnostic value of a 3D-SPACE-sequence with compressed sensing technology for the knee joint].

Radiologe 2021 Feb 21;61(2):203-212. Epub 2020 Dec 21.

Radiologisches Zentrum für Diagnostik und Therapie München, Oberföhringer Straße 2, 81679, München, Deutschland.

Backround: SPACE (3D fast spin echo acquisition) sequences require long scan times for three-dimensional assessment of acute injury of the knee joint and are flawed due to geometric blurring. Their implementation into routine diagnostic imaging was not feasible until recently.

Objectives: By comparing conventional MRI (magnetic resonance imaging) sequences to 3D (three-dimensional) sequences, it was investigated whether the compressed sensing (CS) technique is inferior to the established 2D sequences with shorter examination times.

Materials And Methods: A total of 109 patients (age range 18-50 years) with knee injury were examined by MRI between April 2017 and May 2018. The inter- and intraobserver concordance of two blinded readers were assessed. Consensus was achieved in case of discrepancies. Descriptive analyses of absolute and relative frequency and distribution were tested by Fisher's exact test concerning differences between CS-SPACE and standard proton density fat suppressed imaging.

Results: Interoberserver concordance (IC) of conventional sequences before/after consensus amounted to 58.8/68.1% (medial meniscus, MM), 68.8/88.7% (lateral meniscus, LM) 88.9/97.2% (anterior cruciate ligament, ACL), 99/100% (posterior cruciate ligament, PCL), 88.9/97.2% (collateral ligament, CL) and chondral injury (CI) 1-2: 64.2%, CI-3: 77% and CI-4: 76%. The IC of CS-SPACE amounted before/after consensus of MM to 50.4/77%, LM 68.8/88%, ACL 89.9/94.5%, PCL 97.2/99.0%, CL 92.6/96.3%. IC of CI was evaluated without consensus and amounted to 65.1% (CI 1-2), 66% (CI 3) and 81.6% (CI 4).

Conclusions: Injuries of ACL, PCL and CL have excellent IC between 3D and 2D sequences. Excellent IC could be found in CI grade 3 and 4 when using 2D sequences and CI grade 4 utilizing CS-SPACE. Our results indicate that CS-SPACE is useful in diagnosing acute knee injuries.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00117-020-00788-xDOI Listing
February 2021

High Intensity Resistance Exercise Training vs. High Intensity (Endurance) Interval Training to Fight Cardiometabolic Risk Factors in Overweight Men 30-50 Years Old.

Front Sports Act Living 2020 16;2:68. Epub 2020 Jun 16.

Institute of Medical Physics, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.

Cardiovascular and cardiometabolic diseases are leading causes of death worldwide. Exercise favorably affects this problem, however only few invest (enough) time to favorably influence cardiometabolic risk-factors and cardiac morphology/performance. Time-effective, high-intensity, low-volume exercise protocols might increase people's commitment to exercise. To date, most research has focused on high-intensity interval training (HIIT), the endurance type of HIT, while corresponding HIT-resistance training protocols (HIT-RT) are rarely evaluated. In this study we compared the effect of HIIT vs. HIT-RT, predominately on cardiometabolic and cardiac parameters in untrained, overweight-obese, middle-aged men. Eligible, untrained men aged 30-50 years old in full-time employment were extracted from two joint exercise studies that randomly assigned participants to a HIIT, HIT-RT or corresponding control group. HIIT predominately consisted of interval training 90 s-12 min, (2-4 sessions/week), HIT-RT (2-3 sessions/week) was applied as a single set resistance training to muscular failure. Core intervention length of both protocols was 16 weeks. Main inclusion criteria were overweight-obese status (BMI 25-35 kg/m) and full employment (occupational working time: ≥38.5 h/week). Primary study-endpoint was the Metabolic Syndrome (MetS) Z-Score, secondary study-endpoints were ventricular stroke volume index (SVI) and myocardial mass index (MMI) as determined by Magnetic Resonance Imaging. The Intention to treat (ITT) principle was applied to analyze the summarized data set. Twenty-seven eligible men of the HIT-RT and 30 men of the HIIT group were included in the ITT. Both interventions significantly ( < 0.001) improve the MetS Z-Score, however the effect of HIIT was superior ( = 0.049). In parallel, HIT-RT and HIIT significantly affect SVI and MMI, with the effect of HIIT being much more pronounced ( < 0.001). Although HIIT endurance exercise was superior in favorably affecting cardiometabolic risk and particularly cardiac performance, both exercise methods positively affect cardiometabolic risk factors in this overweight to obese, middle-aged cohort of males with low time resources. Thus, the main practical application of our finding might be that in general overweight-obese people can freely choose their preferred exercise type (HIIT-END or HIT-RT) to improve their cardiometabolic health, while investing an amount of time that should be feasible for everybody. NCT01406730, NCT01766791.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3389/fspor.2020.00068DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7739822PMC
June 2020

Precision of handheld multispectral optoacoustic tomography for muscle imaging.

Photoacoustics 2021 Mar 11;21:100220. Epub 2020 Nov 11.

Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nürnberg, Erlangen, Germany.

Photo-or optoacoustic imaging (OAI) allows quantitative imaging of target tissues. Using multi-wavelength illumination with subsequent ultrasound detection, it may visualize a variety of different chromophores at centimeter depth. Despite its non-invasive, label-free advantages, the precision of repeated measurements for clinical applications is still elusive. We present a multilayer analysis of n = 1920 imaging datasets obtained from a prospective clinical trial (NCT03979157) in n = 10 healthy adult volunteers. All datasets were analyzed for 13 single wavelengths (SWL) between 660 nm-1210 nm and five MSOT-parameters (deoxygenated/oxygenated/total hemoglobin, collagen and lipid) by a semi-automated batch mode software. Intraclass correlation coefficients (ICC) were good to excellent for intrarater (SWL: 0.82-0.92; MSOT-parameter: 0.72-0.92) and interrater reproducibility (SWL: 0.79-0.87; MSOT-parameter: 0.78-0.86), with the exception for MSOT-parameter lipid (interrater ICC: 0.56). Results were stable over time, but exercise-related effects as well as inter-and intramuscular variability were observed. The findings of this study provide a framework for further clinical OAI implementation.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.pacs.2020.100220DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7723806PMC