Mehdi Soltanshahi - Taleghani Educational Hospital

Mehdi Soltanshahi

Taleghani Educational Hospital

Sumy | Iran (Islamic Republic of)

Main Specialties: Nuclear Medicine

Mehdi Soltanshahi - Taleghani Educational Hospital

Mehdi Soltanshahi

Introduction

Primary Affiliation: Taleghani Educational Hospital - Sumy , Iran (Islamic Republic of)

Specialties:

Publications

6Publications

118Reads

51Profile Views

The impact of nonstandard hip rotation on densitometric results of hip regions and potential misclassification of diagnosis.

Arch Osteoporos 2019 08 1;14(1):86. Epub 2019 Aug 1.

Department of Nuclear Medicine, Taleghani Educational Hospital, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11657-019-0635-9DOI Listing
August 2019
1 Read

Poor tracking of myocardial walls and inaccurate estimation of systolic parameters in myocardial hypertrophy on gated myocardial perfusion SPECT resulted from erroneous placement of region of interest and contouring: A pitfall of commercially available software packages for cardiac analysis.

J Nucl Cardiol 2019 Aug 13;26(4):1376-1379. Epub 2018 Jul 13.

Department of Cardiology, Modarres Educational Hospital, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12350-018-1369-6DOI Listing
August 2019
11 Reads
2.942 Impact Factor

The impact of patient-to-detector distance on LV volumes and TID index on SPECT myocardial perfusion imaging: Emphasis on consistent patient-detector positioning in stress and rest phases.

J Nucl Cardiol 2019 02 17;26(1):333-336. Epub 2018 Jan 17.

Department of Nuclear Medicine, Taleghani Educational Hospital, School of Medicine, Shahid Beheshti University of Medical Sciences, Yaman St., Velenjak, Tehran, Iran.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12350-018-1193-zDOI Listing
February 2019
8 Reads
2.942 Impact Factor

A practical method to reduce breast attenuation during SPECT myocardial perfusion imaging.

J Nucl Cardiol 2018 12 11;25(6):2179-2181. Epub 2018 Jan 11.

Department of Nuclear Medicine, Taleghani Educational Hospital, School of Medicine, Shahid Beheshti University of Medical Sciences, Yaman St, Tehran, Iran.

View Article

Download full-text PDF

Source
http://link.springer.com/10.1007/s12350-017-1173-8
Publisher Site
http://dx.doi.org/10.1007/s12350-017-1173-8DOI Listing
December 2018
17 Reads
2.942 Impact Factor

Quantitation in Dextrocardia on myocardial perfusion imaging: how to perform quantitative analysis using Cedars-Sinai software.

Nucl Med Rev Cent East Eur 2018 ;21(1):50-52

Department of Nuclear Medicine, Taleghani Educational Hospital, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.5603/NMR.a2018.0010DOI Listing
August 2018
57 Reads