Age-adjusted D-dimer cut-off levels to rule out venous thromboembolism in patients with non-high pre-test probability: Clinical performance and cost-effectiveness analysis.

J Thromb Haemost 2021 Feb 26. Epub 2021 Feb 26.

Hematology Department, Côte d'Azur University, Pasteur University Hospital, Nice, France.

Background: As aging was found to be associated with increased D-dimer levels, the question arose whether D-dimer measurement was useful in the diagnostic strategy of venous thromboembolism (VTE) in elderly patients.

Aim Of The Study: To compare retrospectively the performance of six diagnostic strategies based on the three-level Wells scores and various cut-off levels for D-dimer, evaluated using the HemosIL D-Dimer HS 500 assay, in a derivation cohort of 644 outpatients with non-high pretest probability (PTP) of VTE. The clinical usefulness of the best-performing strategy was then confirmed in a multicenter validation study involving 1255 consecutive outpatients with non-high PTP.

Results: The diagnostic strategy based on the age-adjusted cut-off level calculated by multiplying the patient's age by 10 above 50 years was found to perform the best in the derivation study with a better sensitivity-to-specificity ratio than the conventional strategy based on the fixed cut-off level (500 ng/ml), a higher specificity and a negative predictive value (NPV) above 99%. Such an increase in test specificity was confirmed in the validation cohort, with the NPV remaining above 99%. Taking into account the local reimbursement rates of diagnostic tests, using this strategy led to a 6.9% reduction of diagnostic costs for pulmonary embolism and a 5.1% reduction for deep vein thrombosis, as imaging tests would be avoided in a higher percentage of patients.

Conclusion: The diagnostic strategy of VTE based on the age-adjusted cut-off level for D-dimer in patients over 50 years was found to be safe, with NPV above 99%, and cost-effective.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1111/jth.15278DOI Listing
February 2021

Guidelines for certification of International Normalized Ratio (INR) for vitamin K antagonists monitoring according to the EN ISO 22870 standards.

Ann Biol Clin (Paris) 2018 Jun;76(3):271-299

Laboratoire central d'hématologie, Hôpital Necker, AP-HP, Paris, France.

Point of care testing (POCT) must comply with regulatory requirements according to standard EN ISO 22870, which identify biologists as responsible for POCT. INR for vitamin K antagonists (VKAs) monitoring is a test frequently performed in haemostasis laboratories. Bedside INR is useful in emergency room, in particular in case of VKAs overdosage but also for specific populations of patients like paediatrics or geriatrics. INR POCT devices are widely used at home by the patients for self-testing, but their use in the hospital by the clinical staff for bedside measurement is growing, with devices which now comply with standard for POCT accreditation for hospital use. The majority of point of care devices for INR monitoring has shown a good precision and accuracy with results similar to those obtained in laboratory. With the aim to help the multidisciplinary groups for POCT supervision, the medical departments and the biologists to be in accordance with the standard, we present the guidelines of the GFHT (Groupe français d'étude sur l'hémostase et la thrombose, subcommittee "CEC et biologie délocalisée") for the certification of POCT INR. These guidelines are based on the SFBC guidelines for the certification of POCT and on the analysis of the literature to ascertain the justification of clinical need and assess the analytical performance of main analysers used in France, as well as on a survey conducted with biologists.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1684/abc.2018.1332DOI Listing
June 2018

Age dependency for coagulation parameters in paediatric populations. Results of a multicentre study aimed at defining the age-specific reference ranges.

Thromb Haemost 2016 07 17;116(1):9-16. Epub 2016 Mar 17.

Dr. Pierre Toulon, CHU Nice, Hôpital Pasteur, Service d'Hématologie Biologique, 30, avenue de la Voie Romaine, CS 51069, F-06001 Nice Cedex 1, France, Tel.: + 33 4 92 03 87 09, Fax: + 33 4 92 03 85 95, E-mail:

Understanding of developmental haemostasis is critical to ensure optimal prevention, diagnosis, and treatment of haemorrhagic and thrombotic diseases in children. As coagulation test results are known to be dependent on the reagents/analysers used, it is recommended for each laboratory to define the age-dependent reference ranges by using its own technical condition. That study was carried out in seven centers to establish age-specific reference ranges using the same reagents and analyser. Plasma samples were obtained from 1437 paediatric patients from the following age groups: 15 days-4 weeks (n=36), 1-5 months (n=320), 6-12 months (n=176), 1-5 years (n=507), 6-10 years (n=132) and 11-17 years (n=262). Indication of coagulation testing was pre-operative screening for non-acute diseases in most cases. PT values were similar in the different age groups to those in adults, whereas longer aPTTs were demonstrated in the younger children. Plasma levels of all clotting factors, except for FV, were significantly decreased (p<0.0001) in the youngest children, adult values being usually reached before the end of the first year. The same applied to antithrombin, protein C/S, and plasminogen. In contrast, FVIII and VWF levels were elevated in the youngest children and returned to adult values within six months. The same applied to D-dimer levels, which were found elevated, particularly until six months of life, until puberty. These data suggest that most coagulation test results are highly dependent on age, mainly during the first year of life, and that age-specific reference ranges must be used to ensure proper evaluation of coagulation in children.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1160/TH15-12-0964DOI Listing
July 2016

[Near-patient testing devices to monitor vitamin K antagonists].

Ann Biol Clin (Paris) 2013 Nov;71:59-69

Laboratoire d'hématologie, CHU Côte de Nacre, Caen.

Monitoring of the anticoagulant effect with the International normalized ratio (INR) is essential for patients receiving vitamin K antagonists (VKAs). The majority of point of care (POC) devices for INR monitoring has shown a good precision and accuracy with results similar to those obtained in a laboratory. In many countries, INR POC devices are widely used at home by the patients for self-testing. Their use in the hospital by the clinical staff (doctor or nurses) for bedside measurement is also growing. The INR POC testing is performed using fully automated devices. Capillary blood samples are easy to obtain. In the emergency room, POC INR devices are commonly used. This improves the quality of care for patient with suspicion of VKAs overdosage. INR measurement using bedside monitors is also of great interest in care units for specific populations of patients like paediatrics or geriatrics. Moreover, bedside INR monitoring may be useful in anticoagulant clinics or when the care unit is far from a laboratory. Although the bedside INR monitors are easy to use, their implementation requires adequate training and intermittent re-evaluation of any person performing the tests to ensure reliability of results. Such equipment must comply with EN ISO 22870 standard for POC testing accreditation, under the supervision of a biologist. In order to achieve these targets, connect the instrument to the laboratory's data management system is essential.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1684/abc.2013.0904DOI Listing
November 2013