Publications by authors named "Juanita Swickard"

2 Publications

  • Page 1 of 1

Detection of SARS-CoV-2 infection in asymptomatic populations using the DiaSorin molecular Simplexa and Roche Cobas EUA assays.

Diagn Microbiol Infect Dis 2021 Jul 31;102(1):115513. Epub 2021 Jul 31.

OhioHealth Laboratory Services, OhioHealth, Columbus, OH, USA; CORPath Pathology Services, LLC, Columbus, OH, USA.

Identification of asymptomatic patients is necessary to control the COVID-19 pandemic and testing is one of the measures to detect this population. We evaluated the clinical correlation of the DiaSorin Molecular Simplexa COVID-19 Direct (DiaSorin Molecular) and Roche Cobas 6800 SARS-CoV-2 (Roche) assays using 253 oropharyngeal (OP) swab specimens collected from asymptomatic patients. Agreement between DiaSorin Molecular and Roche was 97% (95% CI, 0.94 to 0.99), with a κ statistic of 0.90 (95% CI, 0.83 to 0.97) and a PPA of 89% (95% CI, 0.76 to 0.96) and NPA of 99% (95% CI, 0.97 to 0.99). Simple regression analysis of Ct values revealed a regression line of y = 1.065*X - 5.537 with a Pearson's r of 0.8542, indicating a good correlation between both platforms. The DiaSorin Molecular assay demonstrates clinical performance comparable to that of Roche in this population.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.diagmicrobio.2021.115513DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8324421PMC
July 2021

Clinical Evaluation and Utilization of Multiple Molecular In Vitro Diagnostic Assays for the Detection of SARS-CoV-2.

Am J Clin Pathol 2020 07;154(2):201-207

OhioHealth Laboratory Services, Columbus.

Objectives: To evaluate the clinical performance of 3 molecular assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2).

Methods: We used 184 nasopharyngeal swab specimens to compare Abbott ID NOW COVID-19 (Abbott ID NOW), DiaSorin Molecular Simplexa COVID-19 Direct (DiaSorin Simplexa), and Roche cobas 6800 SARS-CoV-2 (Roche cobas) assays. In a separate analysis, 3 specimens (nasopharyngeal, oropharyngeal, and nasal) were collected from 182 unique patients presenting to the emergency department with suspicion of coronavirus disease 2019 and were tested utilizing Abbott ID NOW. To further characterize each assay, relative limits of detection were evaluated utilizing positive nasopharyngeal patient samples.

Results: The positive percent agreement was 91% (95% confidence interval [CI], 0.76-0.97) for Abbott ID NOW and 100% (95% CI, 0.90-1.00) for DiaSorin Simplexa and Roche cobas. The negative percent agreement was 100% (95% CI, 0.98-1.00) for all 3 assays. All swab types tested with the Abbott assay produced concordant results. Polymerase chain reaction assays had approximately 10 to 100 times lower limits of detection than Abbott ID NOW.

Conclusions: Based on these evaluations, a multiplatform testing approach is proposed, depending on patient population and assay sensitivity, to address testing needs during a public health emergency.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1093/ajcp/aqaa097DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7314271PMC
July 2020
-->