Implementation of the Australian Computer-Assisted Theragnostics (AusCAT) network for radiation oncology data extraction, reporting and distributed learning.

J Med Imaging Radiat Oncol 2021 Aug 31;65(5):627-636. Epub 2021 Jul 31.

Institute of Medical Physics, School of Physics, University of Sydney, Sydney, New South Wales, Australia.

Introduction: There is significant potential to analyse and model routinely collected data for radiotherapy patients to provide evidence to support clinical decisions, particularly where clinical trials evidence is limited or non-existent. However, in practice there are administrative, ethical, technical, logistical and legislative barriers to having coordinated data analysis platforms across radiation oncology centres.

Methods: A distributed learning network of computer systems is presented, with software tools to extract and report on oncology data and to enable statistical model development. A distributed or federated learning approach keeps data in the local centre, but models are developed from the entire cohort.

Results: The feasibility of this approach is demonstrated across six Australian oncology centres, using routinely collected lung cancer data from oncology information systems. The infrastructure was used to validate and develop machine learning for model-based clinical decision support and for one centre to assess patient eligibility criteria for two major lung cancer radiotherapy clinical trials (RTOG-9410, RTOG-0617). External validation of a 2-year overall survival model for non-small cell lung cancer (NSCLC) gave an AUC of 0.65 and C-index of 0.62 across the network. For one centre, 65% of Stage III NSCLC patients did not meet eligibility criteria for either of the two practice-changing clinical trials, and these patients had poorer survival than eligible patients (10.6 m vs. 15.8 m, P = 0.024).

Conclusion: Population-based studies on routine data are possible using a distributed learning approach. This has the potential for decision support models for patients for whom supporting clinical trial evidence is not applicable.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1111/1754-9485.13287DOI Listing
August 2021

Calculation algorithms and penumbra: Underestimation of dose in organs at risk in dosimetry audits.

Med Phys 2021 Jul 21. Epub 2021 Jul 21.

Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.

Purpose: The aim of this study is to investigate overdose to organs at risk (OARs) observed in dosimetry audits in Monte Carlo (MC) algorithms and Linear Boltzmann Transport Equation (LBTE) algorithms. The impact of penumbra modeling on OAR dose was assessed with the adjustment of MC modeling parameters and the clinical relevance of the audit cases was explored with a planning study of spine and head and neck (H&N) patient cases.

Methods: Dosimetric audits performed by the Australian Clinical Dosimetry Service (ACDS) of 43 anthropomorphic spine plans and 1318 C-shaped target plans compared the planned dose to doses measured with ion chamber, microdiamond, film, and ion chamber array. An MC EGSnrc model was created to simulate the C-shape target case. The electron cut-off energy E was set at 500, 200, and 10 keV, and differences between 1 and 3 mm voxel were calculated. A planning study with 10 patient stereotactic body radiotherapy (SBRT) spine plans and 10 patient H&N plans was calculated in both Acuros XB (AXB) v15.6.06 and Anisotropic Analytical Algorithm (AAA) v15.6.06. The patient contour was overridden to water as only the penumbral differences between the two different algorithms were under investigation.

Results: The dosimetry audit results show that for the SBRT spine case, plans calculated in AXB are colder than what is measured in the spinal cord by 5%-10%. This was also observed for other audit cases where a C-shape target is wrapped around an OAR where the plans were colder by 3%-10%. Plans calculated with Monaco MC were colder than measurements by approximately 7% with the OAR surround by a C-shape target, but these differences were not noted in the SBRT spine case. Results from the clinical patient plans showed that the AXB was on average 7.4% colder than AAA when comparing the minimum dose in the spinal cord OAR. This average difference between AXB and AAA reduced to 4.5% when using the more clinically relevant metric of maximum dose in the spinal cord. For the H&N plans, AXB was cooler on average than AAA in the spinal cord OAR (1.1%), left parotid (1.7%), and right parotid (2.3%). The EGSnrc investigation also noted similar, but smaller differences. The beam penumbra modeled by E  = 500 keV was steeper than the beam penumbra modeled by E  = 10 keV as the full scatter is not accounted for, which resulted in less dose being calculated in a central OAR region where the penumbra contributes much of the dose. The dose difference when using 2.5 mm voxels of the center of the OAR between 500 and 10 keV was 3%, reducing to 1% between 200 and 10 keV.

Conclusions: Lack of full penumbral modeling due to approximations in the algorithms in MC based or LBTE algorithms are a contributing factor as to why these algorithms under-predict the dose to OAR when the treatment volume is wrapped around the OAR. The penumbra modeling approximations also contribute to AXB plans predicting colder doses than AAA in areas that are in the vicinity of beam penumbra. This effect is magnified in regions where there are many beam penumbras, for example in the spinal cord for spine SBRT cases.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.15123DOI Listing
July 2021

Measuring the dose in bone for spine stereotactic body radiotherapy.

Phys Med 2021 Apr 25;84:265-273. Epub 2021 Mar 25.

Australian Clinical Dosimetry Service, Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Australia.

Purpose: Current quality assurance of radiotherapy involving bony regions generally utilises homogeneous phantoms and dose calculations, ignoring the challenges of heterogeneities with dosimetry problems likely occurring around bone. Anthropomorphic phantoms with synthetic bony materials enable realistic end-to-end testing in clinical scenarios. This work reports on measurements and calculated corrections required to directly report dose in bony materials in the context of comprehensive end-to-end dosimetry audit measurements (63 plans, 6 planning systems).

Materials And Methods: Radiochromic film and microDiamond measurements were performed in an anthropomorphic spine phantom containing bone equivalent materials. Medium dependent correction factors, k, were established using 6 MV and 10 MV Linear Accelerator Monte Carlo simulations to account for the detectors being calibrated in water, but measuring in regions of bony material. Both cortical and trabecular bony material were investigated for verification of dose calculations in dose-to-medium (D) and dose-to-water (D) scenarios.

Results: For D calculations, modelled correction factors for cortical and trabecular bone in film measurements, and for trabecular bone in microDiamond measurements were 0.875(±0.1%), 0.953(±0.3%) and 0.962(±0.4%), respectively. For D calculations, the corrections were 0.920(±0.1%), 0.982(±0.3%) and 0.993(±0.4%), respectively. In the audit, application of the correction factors improves the mean agreement between treatment plans and measured microDiamond dose from -2.4%(±3.9%) to 0.4%(±3.7%).

Conclusion: Monte Carlo simulations provide a method for correcting the dose measured in bony materials allowing more accurate comparison with treatment planning system doses. In verification measurements, algorithm specific correction factors should be applied to account for variations in bony material for calculations based on D and D.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2021.03.011DOI Listing
April 2021

Report dose-to-medium in clinical trials where available; a consensus from the Global Harmonisation Group to maximize consistency.

Radiother Oncol 2021 06 17;159:106-111. Epub 2021 Mar 17.

Trans Tasman Radiation Oncology Group (TROG), Newcastle, Australia; Radiation Oncology Department, Calvary Mater Newcastle, Australia; School of Mathematical and Physical Sciences, University of Newcastle, Australia; Institute of Medical Physics, University of Sydney, Australia.

Purpose: To promote consistency in clinical trials by recommending a uniform framework as it relates to radiation transport and dose calculation in water versus in medium.

Methods: The Global Quality Assurance of Radiation Therapy Clinical Trials Harmonisation Group (GHG; www.rtqaharmonization.org) compared the differences between dose to water in water (D), dose to water in medium (D), and dose to medium in medium (D). This was done based on a review of historical frameworks, existing literature and standards, clinical issues in the context of clinical trials, and the trajectory of radiation dose calculations. Based on these factors, recommendations were developed.

Results: No framework was found to be ideal or perfect given the history, complexity, and current status of radiation therapy. Nevertheless, based on the evidence available, the GHG established a recommendation preferring dose to medium in medium (D).

Conclusions: Dose to medium in medium (D) is the preferred dose calculation and reporting framework. If an institution's planning system can only calculate dose to water in water (D), this is acceptable.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2021.03.006DOI Listing
June 2021

Organ at risk delineation for radiation therapy clinical trials: Global Harmonization Group consensus guidelines.

Radiother Oncol 2020 09 3;150:30-39. Epub 2020 Jun 3.

National Radiotherapy Trials Quality Assurance (RTTQA) Group, Mount Vernon Cancer Centre, United Kingdom.

Background And Purpose: The Global Quality Assurance of Radiation Therapy Clinical Trials Harmonization Group (GHG) is a collaborative group of Radiation Therapy Quality Assurance (RTQA) Groups harmonizing and improving RTQA for multi-institutional clinical trials. The objective of the GHG OAR Working Group was to unify OAR contouring guidance across RTQA groups by compiling a single reference list of OARs in line with AAPM TG 263 and ASTRO, together with peer-reviewed, anatomically defined contouring guidance for integration into clinical trial protocols independent of the radiation therapy delivery technique.

Materials And Methods: The GHG OAR Working Group comprised of 22 multi-professional members from 6 international RTQA Groups and affiliated organizations conducted the work in 3 stages: (1) Clinical trial documentation review and identification of structures of interest (2) Review of existing contouring guidance and survey of proposed OAR contouring guidance (3) Review of survey feedback with recommendations for contouring guidance with standardized OAR nomenclature.

Results: 157 clinical trials were examined; 222 OAR structures were identified. Duplicates, non-anatomical, non-specific, structures with more specific alternative nomenclature, and structures identified by one RTQA group were excluded leaving 58 structures of interest. 6 OAR descriptions were accepted with no amendments, 41 required minor amendments, 6 major amendments, 20 developed as a result of feedback, and 5 structures excluded in response to feedback. The final GHG consensus guidance includes 73 OARs with peer-reviewed descriptions (Appendix A).

Conclusion: We provide OAR descriptions with standardized nomenclature for use in clinical trials. A more uniform dataset supports the delivery of clinically relevant and valid conclusions from clinical trials.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2020.05.038DOI Listing
September 2020

The effect of the horizontal metallic drive on reference dosimetry in the SNC 3D scanner water tank.

J Appl Clin Med Phys 2020 Apr 1;21(4):95-101. Epub 2020 Apr 1.

Department of Radiation Oncology, Calvary Mater Hospital, Newcastle, NSW, 2298, Australia.

Accurate quantification of absorbed radiation dose is important for safe and effective delivery of radiation therapy. An important aspect to this is reference dosimetry, which is performed under reference conditions specified by international codes of practice. Such measurements are usually performed in a water phantom. In the Sun Nuclear Corporation (SNC) three-dimensional (3D) scanner water tank system the detector holder is fixed to a horizontal metallic drive rail (MDR) which is in close proximity to the active volume of the detector. In this project, the dosimetric effects of the MDR on reference dosimetry were investigated for MV photons, MeV electrons, and kV photons by comparing reference dosimetry measurements in the SNC 3D scanner against similar measurements in a Standard Imaging (SI) one-dimensional (1D) tank and against measurements in the SNC 3D scanner with an additional, custom-made spacer placed beneath the chamber holder to increase the chamber - MDR separation. A second experiment investigated the difference in chamber reading dependent on chamber to MDR separation by fixing the chamber in the tank independently of the MDR and successively moving the MDR vertically to alter the separation. The results showed that measurements in the SNC 3D scanner agree with both SI 1D tank and SNC 3D scanner with spacer to within ±0.3% for MV photons, ±0.1% for electrons and ±1.2% for kV photons within the calculated setup uncertainty. The second experiment showed that the contribution of backscatter from the MDR was significant if the distance between MDR and chamber was reduced below the chamber's designed position in the SNC 3D scanner. The exception was for kV photons where the contribution of backscatter from the MDR was measured to be 0.5% at the designed distance. Further investigation would be useful for kV photons, where the experiment showed relatively large measurement uncertainties.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1002/acm2.12858DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7170281PMC
April 2020

Credentialing of vertebral stereotactic ablative body radiotherapy in a multi-centre trial.

Phys Med 2020 Apr 17;72:16-21. Epub 2020 Mar 17.

Radiation Oncology, Peter MacCallum Cancer Centre, VIC, Australia; Sir Peter MacCallum Cancer Centre, University of Melbourne, VIC, Australia.

Purpose/objective: Stereotactic ablative body radiotherapy (SABR) in multi-centre trials requires rigorous quality assurance to ensure safe and consistent treatment for all trial participants. We report results of vertebral SABR dosimetry credentialing for the ALTG/TROG NIVORAD trial.

Material/methods: Centres with a previous SABR site visit performed axial film measurement of the benchmarking vertebral plan in a local phantom and submitted radiochromic film images for analysis. Remaining centres had on-site review of SABR processes and axial film measurement of the vertebral benchmarking plan. Films were analysed for dosimetric and positional accuracy: gamma analysis (>90% passing 2%/2mm/10% threshold) and ≤ 1 mm positional accuracy at target-cord interface was required.

Results: 19 centres were credentialed; 11 had on-site measurement. Delivery devices included linear accelerator, TomoTherapy and CyberKnife systems. Five centres did not achieve 90% gamma passing rate. Of these, three were out of tolerance (OOT) in low (<5Gy) dose regions and > 80% passing rate and deemed acceptable. Two were OOT over the full dose range: one elected not to remeasure; the other also had positional discrepancy greater than 1 mm and repeat measurement with a new plan was in tolerance. The original OOT was attributed to inappropriate MLC constraints. All centres delivered planned target-cord dose gradient within 1 mm.

Conclusion: Credentialing measurements for vertebral SABR in a multi-centre trial showed although the majority of centres delivered accurate vertebral SABR, there is high value in independent audit measurements. One centre with inappropriate MLC settings was detected, which may have resulted in delivery of clinically unacceptable vertebral SABR plans.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2020.03.004DOI Listing
April 2020

A comparison of IROC and ACDS on-site audits of reference and non-reference dosimetry.

Med Phys 2019 Dec 25;46(12):5878-5887. Epub 2019 Oct 25.

Australian Clinical Dosimetry Service, ARPANSA, Melbourne, Australia.

Purpose: Consistency between different international quality assurance groups is important in the progress toward similar standards and expectations in radiotherapy dosimetry around the world, and in the context of consistent clinical trial data from international trial participants. This study compares the dosimetry audit methodology and results of two international quality assurance groups performing a side-by-side comparison at the same radiotherapy department, and interrogates the ability of the audits to detect deliberately introduced errors.

Methods: A comparison of the core dosimetry components of reference and non-reference audits was conducted by the Imaging and Radiation Oncology Core (IROC, Houston, USA) and the Australian Clinical Dosimetry Service (ACDS, Melbourne, Australia). A set of measurements were conducted over 2 days at an Australian radiation therapy facility in Melbourne. Each group evaluated the reference dosimetry, output factors, small field output factors, percentage depth dose (PDD), wedge, and off-axis factors according to their standard protocols. IROC additionally investigated the Electron PDD and the ACDS investigated the effect of heterogeneities. In order to evaluate and compare the performance of these audits under suboptimal conditions, artificial errors in percentage depth dose (PDD), EDW, and small field output factors were introduced into the 6 MV beam model to simulate potential commissioning/modeling errors and both audits were tested for their sensitivity in detecting these errors.

Results: With the plans from the clinical beam model, almost all results were within tolerance and at an optimal pass level. Good consistency was found between the two audits as almost all findings were consistent between them. Only two results were different between the results of IROC and the ACDS. The measurements of reference FFF photons showed a discrepancy of 0.7% between ACDS and IROC due to the inclusion of a 0.5% nonuniformity correction by the ACDS. The second difference between IROC and the ACDS was seen with the lung phantom. The asymmetric field behind lung measured by the ACDS was slightly (0.3%) above the ACDS's pass (optimal) level of 3.3%. IROC did not detect this issue because their measurements were all assessed in a homogeneous phantom. When errors were deliberately introduced neither audit was sensitive enough to pick up a 2% change to the small field output factors. The introduced PDD change was flagged by both audits. Similarly, the introduced error of using 25° wedge instead of 30° wedge was detectible in both audits as out of tolerance.

Conclusions: Despite different equipment, approach, and scope of measurements in on-site audits, there were clear similarities between the results from the two groups. This finding is encouraging in the context of a global harmonized approach to radiotherapy quality assurance and dosimetry audit.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.13800DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6916618PMC
December 2019

Impact of magnetic fields on dose measurement with small ion chambers illustrated in high-resolution response maps.

Med Phys 2019 Jul 11;46(7):3298-3305. Epub 2019 Jun 11.

Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), Yallambie, Vic., 3085, Australia.

Purpose: Dosimetry of ionizing radiation in the presence of strong magnetic fields is gaining increased relevance in light of advances for MRI-guided radiation therapy. While the impact of strong magnetic fields on the overall response of ionization chambers has been simulated and measured before, this work investigates the local impact of the magnetic field on dose response in an ion chamber. High-resolution 1D and 2D response maps have been created for two small clinical thimble ionization chambers, the PinPoint chambers 31006 and 31014 (Physikalisch Technische Werkstaetten Freiburg, Germany).

Methods: Working on the Imaging and Medical Beam Line of the Australian Synchrotron an intense kilovoltage radiation beam with very low divergence, collimated to 0.1 mm was used to scan the chambers by moving them on a 2D motion platform. Measured current and beam position were correlated to create the response maps. Small neodymium magnets were used to create a field of about 0.25 T. Chamber axis, magnetic field, and beam direction were perpendicular to each other. Measurements were performed with both orientations of the magnetic field as well as without it. Chamber biases of 5 and 250 V in both polarities were used.

Results: The local distribution of the response of small thimble-type ionization chambers was found to be impacted by a magnetic field. Depending on the orientation of the magnetic field, the chamber response near the stem was either enhanced or reduced with the response near the tip behaving the opposite way. Local changes were in the order of up to 40% compared to measurements without the magnetic field present. Bending of the central electrode was observed for the chamber with the steel electrode. The size of the volume of reduced collection near the guard electrode was impacted by the magnetic field. As the here investigated beam and field parameters differ from those of clinical systems, quantitatively different results would be expected for the latter. However, the gyroradii encountered here were similar to those of a 6-7 MV MRI linac with a 1.5 T magnet.

Conclusions: Magnetic fields impact the performance of ionization chambers also on a local level. For practical measurements this might mean a change in the effective point of measurement, in addition to any global corrections. Further knowledge about the local response will help in selecting or constructing optimized chambers for use in magnetic fields.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.13591DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6852318PMC
July 2019

Assessment of the accuracy of truebeam intrafraction motion review (IMR) system for prostate treatment guidance.

Australas Phys Eng Sci Med 2019 Jun 13;42(2):585-598. Epub 2019 May 13.

Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, NSW, Australia.

Intrafraction motion review (IMR), a real-time 2D, motion management feature of the Varian Truebeam™ incorporates triggered imaging, automatic fiducial marker detection and automatic beam hold. With the increasing adoption of high dose per fraction stereotactic body radiotherapy (SBRT) this system provides a potential means to ensure treatment accuracy. The goal of this study was therefore to investigate and quantify key performance characteristics of IMR for prostate treatment guidance. Phantom experiments were performed with a custom Computerized Imaging Reference Systems, Inc (CIRS) pelvis phantom with implanted gold seeds and the Hexamotion™ 5D motion platform. The system accuracy was assessed statically and under typical prostate motion trajectories. The IMR functionality and marker detectability was tested under different anatomical conditions and with different imaging acquisition modes. Imaging dose for triggered imaging modes was determined using an ionisation chamber based on IPEMB dose calibration protocol for kV energies. For zero displacement, the IMR demonstrated submillimeter agreement with the known position. Similarly, dynamic motion differences between the IMR reported position and 2D trajectory displacement were within 1 mm. Static displacement in the anterior direction was reported by IMR as sinusoidal motion on the x-axis (kV angle). The 2D nature of IMR limits the ability to detect motion out of the plane of the kV image detector. Using typical clinical imaging settings, imaging dose determined at the patient surface was 2.58 mGy/frame and the corresponding IMR displayed dose was 2.63 mGy/frame. The methodology used was able to quantify the accuracy of the IMR system. The IMR was able to accurately and consistently report fiducial positions within the limitations inherent of a 2D system. IMR is fully integrated with the Truebeam system with an easy to use and efficient workflow and is clinically beneficial especially within the context of SBRT.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13246-019-00760-7DOI Listing
June 2019

Excessive applicator radiation leakage for a common therapeutic kilovoltage system.

Br J Radiol 2019 Feb 15;92(1094):20180743. Epub 2018 Nov 15.

1 Departmentof Radiation Oncology, Calvary Mater Newcastle , Newcastle, NSW , Australia.

Objective:: The objective of this work is to characterise out- of- field leakage radiation emanating from clinical applicators of the WOmed T-200 kilovoltage therapy machine.

Methods:: To identify points of leakage, radiosensitive film was affixed to the walls and base plate of each applicator. Quantitative assessment of leakage radiation was conducted with a 0.23 cm ionisation chamber following the International Electrotechnical Commission standard. Film was also used to illustrate leakage distribution in the patient plane. Angular and energy dependences of the leakage radiation were quantified as well as a two-dimensional leakage profile in the plane parallel to one applicator.

Results:: Leakage was found when the diameter of primary collimator of the kV tube exceeded the external dimension of the applicator wall. In the patient plane all applicators showed similar leakage rates with the leakage distribution dependent upon applicator design. Mean patient plane leakage was 1.37% of central axis air kerma rate, exceeding the 0.5% limit specified in the standard. Leakage was shown to be profoundly energy dependent with maximum leakage of 11.8% for the 200 kV beam, 1.3% for 150 kV and 0.2% for 100 kV. Angular dependence measurements showed a 10.3% change in leakage between the minimum and maximum positions.

Conclusion: The combination of shielding thickness, primary collimator design and applicator dimensions permits unwanted radiation to contribute dose outside the treatment field when energies ≥150 kV are used.

Advances In Knowledge:: Even carefully designed modern kv therapy systems can exhibit leakage in some areas. Thorough assessment of leakage is needed prior to release for clinical use.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1259/bjr.20180743DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6404815PMC
February 2019

A remote EPID-based dosimetric TPS-planned audit of centers for clinical trials: outcomes and analysis of contributing factors.

Radiat Oncol 2018 Sep 17;13(1):178. Epub 2018 Sep 17.

University of Newcastle, Newcastle, NSW, Australia.

Background: A novel remote method for external dosimetric TPS-planned auditing of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for clinical trials using electronic portal imaging device (EPID) has been developed. The audit has been applied to multiple centers across Australia and New Zealand. This work aims to assess the audit outcomes and explores the variables that contributed to the audit results.

Methods: Thirty audits were performed of 21 radiotherapy facilities, 17 facilities underwent IMRT audits and 13 underwent VMAT audits. The assessment was based on comparisons between the delivered doses derived from images acquired with EPIDs and planned doses from the local treatment planning systems (TPS). Gamma pass-rate (GPR) and gamma mean value (GMV) were calculated for each IMRT field and VMAT arc (total 268 comparisons). A multiple variable linear model was applied to the GMV results (3%/3 mm criteria) to assess the influence and significance of explanatory variables. The explanatory variables were Linac-TPS combination, TPS grid resolution, IMRT/VMAT delivery, age of EPID, treatment site, record and verification system (R&V) type and dose-rate. Finally, the audit results were compared with other recent audits by calculating the incidence ratio (IR) as a ratio of the observed mean/median GPRs for the remote audit to the other audits.

Results: The average (± 1 SD) of the centers' GPRs were: 99.3 ± 1.9%, 98.6 ± 2.7% & 96.2 ± 5.5% at 3%, 3 mm, 3%, 2 mm and 2%, 2 mm criteria respectively. The most determinative variables on the GMVs were Linac-TPS combination, TPS grid resolution and IMRT/VMAT delivery type. The IR values were 1 for seven comparisons, indicating similar GPRs of the remote audit with the reference audits and > 1 for four comparisons, indicating higher GPRs of the remote audit than the reference audits.

Conclusion: The remote dosimetry audit method for clinical trials demonstrated high GPRs and provided results comparable to established more resource-intensive audit methods. Several factors were found to influence the results including some effect of Linac-TPS combination.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1186/s13014-018-1125-8DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6142693PMC
September 2018

Dosimetric end-to-end tests in a national audit of 3D conformal radiotherapy.

Phys Imaging Radiat Oncol 2018 Apr 24;6:5-11. Epub 2018 Apr 24.

Australian Clinical Dosimetry Service (ACDS), Australian Radiation Protection and National Safety Agency (ARPANSA), 619 Lower Plenty Road, Yallambie, VIC 3085, Australia.

Background And Purpose: Independent dosimetry audits improve quality and safety of radiation therapy. This work reports on design and findings of a comprehensive 3D conformal radiotherapy (3D-CRT) Level III audit.

Materials And Methods: The audit was conducted as onsite audit using an anthropomorphic thorax phantom in an end-to-end test by the Australian Clinical Dosimetry Service (ACDS). Absolute dose point measurements were performed with Farmer-type ionization chambers. The audited treatment plans included open and half blocked fields, wedges and lung inhomogeneities. Audit results were determined as Pass Optimal Level (deviations within 3.3%), Pass Action Level (greater than 3.3% but within 5%) and Out of Tolerance (beyond 5%), as well as Reported Not Scored (RNS). The audit has been performed between July 2012 and January 2018 on 94 occasions, covering approximately 90% of all Australian facilities.

Results: The audit pass rate was 87% (53% optimal). Fifty recommendations were given, mainly related to planning system commissioning. Dose overestimation behind low density inhomogeneities by the analytical anisotropic algorithm (AAA) was identified across facilities and found to extend to beam setups which resemble a typical breast cancer treatment beam placement. RNS measurements inside lung showed a variation in the opposite direction: AAA under-dosed a target beyond lung and over-dosed the lung upstream and downstream of the target. Results also highlighted shortcomings of some superposition and convolution algorithms in modelling large angle wedges.

Conclusions: This audit showed that 3D-CRT dosimetry audits remain relevant and can identify fundamental global and local problems that also affect advanced treatments.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.phro.2018.03.006DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807562PMC
April 2018

Continuous breath-hold assessment during breast radiotherapy using portal imaging.

Phys Imaging Radiat Oncol 2018 Jan 8;5:64-68. Epub 2018 Mar 8.

Radiation Oncology Department, Calvary Mater Newcastle, Newcastle, Australia.

View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.phro.2018.02.006DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807561PMC
January 2018

Spatial response of synthetic microDiamond and diode detectors measured with kilovoltage synchrotron radiation.

Med Phys 2018 Feb 18;45(2):943-952. Epub 2018 Jan 18.

Australian Synchrotron, 800 Blackburn Road, Clayton, Vict., 3168, Australia.

Purpose: To map the spatial response of four solid-state radiation detectors of types commonly used for radiotherapy dosimetry.

Methods: PTW model 60016 Diode P, 60017 Diode E, 60018 Diode SRS, and 60019 microDiamond detectors were radiographed using a high resolution conventional X-ray system. Their spatial response was then investigated using a 0.1 mm diameter beam of 95 keV average energy photons generated by a synchrotron. The detectors were scanned through the beam while their signal was recorded as a function of position, to map the response. These 2D response maps were created in both the end-on and side-on orientations.

Results: The results show the location and size of the active region. End-on, the active area was determined to be centrally located and within 0.2 mm of the manufacturer's specified diameter. The active areas of the 60016 Diode P, 60017 Diode E, 60018 Diode SRS detectors are uniform to within approximately 5%. The 60019 microDiamond showed local variations up to 30%. The extra-cameral signal in the microDiamond was calculated from the side-on scan to be approximately 8% of the signal from the active element.

Conclusions: The spatial response of four solid-state detectors has been measured. The technique yielded information about the location and uniformity of the active area, and the extra-cameral signal, for the beam quality used.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.12733DOI Listing
February 2018

A virtual dosimetry audit - Towards transferability of gamma index analysis between clinical trial QA groups.

Radiother Oncol 2017 12;125(3):398-404

Department of Medical Physics, Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK; Metrology for Medical Physics Centre, National Physical Laboratory, Teddington, UK; Radiotherapy Trials QA (RTTQA), UK.

Purpose: Quality assurance (QA) for clinical trials is important. Lack of compliance can affect trial outcome. Clinical trial QA groups have different methods of dose distribution verification and analysis, all with the ultimate aim of ensuring trial compliance. The aim of this study was to gain a better understanding of different processes to inform future dosimetry audit reciprocity.

Materials: Six clinical trial QA groups participated. Intensity modulated treatment plans were generated for three different cases. A range of 17 virtual 'measurements' were generated by introducing a variety of simulated perturbations (such as MLC position deviations, dose differences, gantry rotation errors, Gaussian noise) to three different treatment plan cases. Participants were blinded to the 'measured' data details. Each group analysed the datasets using their own gamma index (γ) technique and using standardised parameters for passing criteria, lower dose threshold, γ normalisation and global γ.

Results: For the same virtual 'measured' datasets, different results were observed using local techniques. For the standardised γ, differences in the percentage of points passing with γ < 1 were also found, however these differences were less pronounced than for each clinical trial QA group's analysis. These variations may be due to different software implementations of γ.

Conclusions: This virtual dosimetry audit has been an informative step in understanding differences in the verification of measured dose distributions between different clinical trial QA groups. This work lays the foundations for audit reciprocity between groups, particularly with more clinical trials being open to international recruitment.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2017.10.012DOI Listing
December 2017

Commissioning of a PTW 34070 large-area plane-parallel ionization chamber for small field megavoltage photon dosimetry.

J Appl Clin Med Phys 2017 Nov 4;18(6):206-217. Epub 2017 Oct 4.

School of Science, RMIT University, Melbourne, Vic., Australia.

Purpose: This study investigates a large-area plane-parallel ionization chamber (LAC) for measurements of dose-area product in water (DAP ) in megavoltage (MV) photon fields.

Methods: Uniformity of electrode separation of the LAC (PTW34070 Bragg Peak Chamber, sensitive volume diameter: 8.16 cm) was measured using high-resolution microCT. Signal dependence on angle α of beam incidence for square 6 MV fields of side length s = 20 cm and 1 cm was measured in air. Polarity and recombination effects were characterized in 6, 10, and 18 MV photons fields. To assess the lateral setup tolerance, scanned LAC profiles of a 1 × 1 cm field were acquired. A 6 MV calibration coefficient, N , was determined in a field collimated by a 5 cm diameter stereotactic cone with known DAP . Additional calibrations in 10 × 10 cm fields at 6, 10, and 18 MV were performed.

Results: Electrode separation is uniform and agrees with specifications. Volume-averaging leads to a signal increase proportional to ~1/cos(α) in small fields. Correction factors for polarity and recombination range between 0.9986 to 0.9996 and 1.0007 to 1.0024, respectively. Off-axis displacement by up to 0.5 cm did not change the measured signal in a 1 × 1 cm field. N was 163.7 mGy cm nC and differs by +3.0% from the coefficient derived in the 10 × 10 cm 6 MV field. Response in 10 and 18 MV fields increased by 1.0% and 2.7% compared to 6 MV.

Conclusions: The LAC requires only small correction factors for DAP measurements and shows little energy dependence. Lateral setup errors of 0.5 cm are tolerated in 1 × 1 cm fields, but beam incidence must be kept as close to normal as possible. Calibration in 10 × 10 fields is not recommended because of the LAC's over-response. The accuracy of relative point-dose measurements in the field's periphery is an important limiting factor for the accuracy of DAP measurements.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1002/acm2.12185DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689907PMC
November 2017

Technical note: TROG 15.01 SPARK trial multi-institutional imaging dose measurement.

J Appl Clin Med Phys 2017 Sep 2;18(5):358-363. Epub 2017 Aug 2.

Radiation Oncology Department, Calvary Mater Newcastle, Waratah, New South Wales, Australia.

Purpose: The Trans-Tasman Radiation Oncology Group (TROG) 15.01 Stereotactic Prostate Adaptive Radiotherapy utilizing Kilovoltage intrafraction monitoring (SPARK) trial is a multicenter trial using Kilovoltage Intrafraction Monitoring (KIM) to monitor prostate position during the delivery of prostate radiation therapy. KIM increases the accuracy of prostate radiation therapy treatments and allows for hypofractionation. However, an additional imaging dose is delivered to the patient. A standardized procedure to determine the imaging dose per frame delivered using KIM was developed and applied at four radiation therapy centers on three different types of linear accelerator.

Methods: Dose per frame for kilovoltage imaging in fluoroscopy mode was measured in air at isocenter using an ion chamber. Beam quality and dose were determined for a Varian Clinac iX linear accelerator, a Varian Trilogy, four Varian Truebeams and one Elekta Synergy at four different radiation therapy centers. The imaging parameters used on the Varian machines were 125 kV, 80 mA, and 13 ms. The Elekta machine was measured at 120 kV, 80 mA, and 12 ms. Absorbed doses to the skin and the prostate for a typical SBRT prostate treatment length were estimated according to the IPEMB protocol.

Results: The average dose per kV frame to the skin was 0.24 ± 0.03 mGy. The average estimated absorbed dose to the prostate for all five treatment fractions across all machines measured was 39.9 ± 2.6 mGy for 1 Hz imaging, 199.7 ± 13.2 mGy for 5 Hz imaging and 439.3 ± 29.0 mGy for 11 Hz imaging.

Conclusions: All machines measured agreed to within 20%. Additional dose to the prostate from using KIM is at most 1.3% of the prescribed dose of 36.25 Gy in five fractions delivered during the trial.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1002/acm2.12151DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5875840PMC
September 2017

A novel and independent method for time-resolved gantry angle quality assurance for VMAT.

J Appl Clin Med Phys 2017 Sep 13;18(5):134-142. Epub 2017 Jul 13.

Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, NSW, Australia.

Volumetric-modulated arc therapy (VMAT) treatment delivery requires three key dynamic components; gantry rotation, dose rate modulation, and multi-leaf collimator motion, which are all simultaneously varied during the delivery. Misalignment of the gantry angle can potentially affect clinical outcome due to the steep dose gradients and complex MLC shapes involved. It is essential to develop independent gantry angle quality assurance (QA) appropriate to VMAT that can be performed simultaneously with other key VMAT QA testing. In this work, a simple and inexpensive fully independent gantry angle measurement methodology was developed that allows quantitation of the gantry angle accuracy as a function of time. This method is based on the analysis of video footage of a "Double dot" pattern attached to the front cover of the linear accelerator that consists of red and green circles printed on A4 paper sheet. A standard mobile phone is placed on the couch to record the video footage during gantry rotation. The video file is subsequently analyzed and used to determine the gantry angle from each video frame using the relative position of the two dots. There were two types of validation tests performed including the static mode with manual gantry angle rotation and dynamic mode with three complex test plans. The accuracy was 0.26° ± 0.04° and 0.46° ± 0.31° (mean ± 1 SD) for the static and dynamic modes, respectively. This method is user friendly, cost effective, easy to setup, has high temporal resolution, and can be combined with existing time-resolved method for QA of MLC and dose rate to form a comprehensive set of procedures for time-resolved QA of VMAT delivery system.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1002/acm2.12129DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5874941PMC
September 2017

Virtual EPID standard phantom audit (VESPA) for remote IMRT and VMAT credentialing.

Phys Med Biol 2017 06 1;62(11):4293-4299. Epub 2017 Mar 1.

School of Mathematical and Physical Sciences, The University of Newcastle, Newcastle, Australia.

A virtual EPID standard phantom audit (VESPA) has been implemented for remote auditing in support of facility credentialing for clinical trials using IMRT and VMAT. VESPA is based on published methods and a clinically established IMRT QA procedure, here extended to multi-vendor equipment. Facilities are provided with comprehensive instructions and CT datasets to create treatment plans. They deliver the treatment directly to their EPID without any phantom or couch in the beam. In addition, they deliver a set of simple calibration fields per instructions. Collected EPID images are uploaded electronically. In the analysis, the dose is projected back into a virtual cylindrical phantom. 3D gamma analysis is performed. 2D dose planes and linear dose profiles are provided and can be considered when needed for clarification. In addition, using a virtual flat-phantom, 2D field-by-field or arc-by-arc gamma analyses are performed. Pilot facilities covering a range of planning and delivery systems have performed data acquisition and upload successfully. Advantages of VESPA are (1) fast turnaround mainly driven by the facility's capability of providing the requested EPID images, (2) the possibility for facilities performing the audit in parallel, as there is no need to wait for a phantom, (3) simple and efficient credentialing for international facilities, (4) a large set of data points, and (5) a reduced impact on resources and environment as there is no need to transport heavy phantoms or audit staff. Limitations of the current implementation of VESPA for trials credentialing are that it does not provide absolute dosimetry, therefore a Level I audit is still required, and that it relies on correctly delivered open calibration fields, which are used for system calibration. The implemented EPID based IMRT and VMAT audit system promises to dramatically improve credentialing efficiency for clinical trials and wider applications.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/aa63dfDOI Listing
June 2017

Dosimetry of ionising radiation in modern radiation oncology.

Phys Med Biol 2016 07 28;61(14):R167-205. Epub 2016 Jun 28.

Peter MacCallum Cancer Centre, Melbourne, Australia. Sir Peter MacCallum Institute, University of Melbourne, Parkville, Australia. RMIT University, School of Science, Engineering and Technology, Melbourne, Australia.

Dosimetry of ionising radiation is a well-established and mature branch of physical sciences with many applications in medicine and biology. In particular radiotherapy relies on dosimetry for optimisation of cancer treatment and avoidance of severe toxicity for patients. Several novel developments in radiotherapy have introduced new challenges for dosimetry with small and dynamically changing radiation fields being central to many of these applications such as stereotactic ablative body radiotherapy and intensity modulated radiation therapy. There is also an increasing awareness of low doses given to structures not in the target region and the associated risk of secondary cancer induction. Here accurate dosimetry is important not only for treatment optimisation but also for the generation of data that can inform radiation protection approaches in the future. The article introduces some of the challenges and highlights the interdependence of dosimetric calculations and measurements. Dosimetric concepts are explored in the context of six application fields: reference dosimetry, small fields, low dose out of field, in vivo dosimetry, brachytherapy and auditing of radiotherapy practice. Recent developments of dosimeters that can be used for these purposes are discussed using spatial resolution and number of dimensions for measurement as sorting criteria. While dosimetry is ever evolving to address the needs of advancing applications of radiation in medicine two fundamental issues remain: the accuracy of the measurement from a scientific perspective and the importance to link the measurement to a clinically relevant question. This review aims to provide an update on both of these.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/61/14/R167DOI Listing
July 2016

National dosimetric audit network finds discrepancies in AAA lung inhomogeneity corrections.

Phys Med 2015 Jul 23;31(5):435-41. Epub 2015 Apr 23.

Australian Clinical Dosimetry Service, Yallambie, Victoria 3085, Australia; School of Applied Science, RMIT University, Melbourne, Australia.

This work presents the Australian Clinical Dosimetry Service's (ACDS) findings of an investigation of systematic discrepancies between treatment planning system (TPS) calculated and measured audit doses. Specifically, a comparison between the Anisotropic Analytic Algorithm (AAA) and other common dose-calculation algorithms in regions downstream (≥2cm) from low-density material in anthropomorphic and slab phantom geometries is presented. Two measurement setups involving rectilinear slab-phantoms (ACDS Level II audit) and anthropomorphic geometries (ACDS Level III audit) were used in conjunction with ion chamber (planar 2D array and Farmer-type) measurements. Measured doses were compared to calculated doses for a variety of cases, with and without the presence of inhomogeneities and beam-modifiers in 71 audits. Results demonstrate a systematic AAA underdose with an average discrepancy of 2.9 ± 1.2% when the AAA algorithm is implemented in regions distal from lung-tissue interfaces, when lateral beams are used with anthropomorphic phantoms. This systemic discrepancy was found for all Level III audits of facilities using the AAA algorithm. This discrepancy is not seen when identical measurements are compared for other common dose-calculation algorithms (average discrepancy -0.4 ± 1.7%), including the Acuros XB algorithm also available with the Eclipse TPS. For slab phantom geometries (Level II audits), with similar measurement points downstream from inhomogeneities this discrepancy is also not seen.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2015.04.002DOI Listing
July 2015

Long term OSLD reader stability in the ACDS level one audit.

Australas Phys Eng Sci Med 2015 Mar 14;38(1):151-6. Epub 2014 Dec 14.

Australian Clinical Dosimetry Service, Yallambie, VIC, 3085, Australia,

The Australian Clinical Dosimetry Service (ACDS) has demonstrated the capacity to perform a basic dosimetry audit on all radiotherapy clinics across Australia. During the ACDS's three and a half year trial the majority of the audits were performed using optically stimulated luminescence dosimeters (OSLD) mailed to facilities for exposure to a reference dose, and then returned to the ACDS for analysis. This technical note investigates the stability of the readout process under the large workload of the national dosimetry audit. The OSLD readout uncertainty contributes to the uncertainty of several terms of the dose calculation equation and is a major source of uncertainty in the audit. The standard deviation of four OSLD readouts was initially established at 0.6 %. Measurements over 13 audit batches--each batch containing 200-400 OSLDs--showed variability (0.5-0.9 %) in the readout standard deviation. These shifts have not yet necessitated a change to the audit scoring levels. However, a standard deviation in OSLD readouts greater than 0.9 % will change the audit scoring levels. We identified mechanical wear on the OSLD readout adapter as a cause of variability in readout uncertainty, however, we cannot rule out other causes. Additionally we observed large fluctuations in the distribution of element correction factors (ECF) for OSLD batches. We conclude that the variability in the width of the ECF distribution from one batch to another is not caused by variability in readout uncertainty, but rather by variations in the OSLD stock.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13246-014-0320-7DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4445253PMC
March 2015

A 2D ion chamber array audit of wedged and asymmetric fields in an inhomogeneous lung phantom.

Med Phys 2014 Oct;41(10):101712

Australian Clinical Dosimetry Service, Yallambie, Victoria 3085, Australia and School of Applied Science, RMIT University, Melbourne 3000, Australia.

Purpose: The Australian Clinical Dosimetry Service (ACDS) has implemented a new method of a nonreference condition Level II type dosimetric audit of radiotherapy services to increase measurement accuracy and patient safety within Australia. The aim of this work is to describe the methodology, tolerances, and outcomes from the new audit.

Methods: The ACDS Level II audit measures the dose delivered in 2D planes using an ionization chamber based array positioned at multiple depths. Measurements are made in rectilinear homogeneous and inhomogeneous phantoms composed of slabs of solid water and lung. Computer generated computed tomography data sets of the rectilinear phantoms are supplied to the facility prior to audit for planning of a range of cases including reference fields, asymmetric fields, and wedged fields. The audit assesses 3D planning with 6 MV photons with a static (zero degree) gantry. Scoring is performed using local dose differences between the planned and measured dose within 80% of the field width. The overall audit result is determined by the maximum dose difference over all scoring points, cases, and planes. Pass (Optimal Level) is defined as maximum dose difference ≤3.3%, Pass (Action Level) is ≤5.0%, and Fail (Out of Tolerance) is >5.0%.

Results: At close of 2013, the ACDS had performed 24 Level II audits. 63% of the audits passed, 33% failed, and the remaining audit was not assessable. Of the 15 audits that passed, 3 were at Pass (Action Level). The high fail rate is largely due to a systemic issue with modeling asymmetric 60° wedges which caused a delivered overdose of 5%-8%.

Conclusions: The ACDS has implemented a nonreference condition Level II type audit, based on ion chamber 2D array measurements in an inhomogeneous slab phantom. The powerful diagnostic ability of this audit has allowed the ACDS to rigorously test the treatment planning systems implemented in Australian radiotherapy facilities. Recommendations from audits have led to facilities modifying clinical practice and changing planning protocols.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.4896097DOI Listing
October 2014

Angular dependence of the response of the nanoDot OSLD system for measurements at depth in clinical megavoltage beams.

Med Phys 2014 Jun;41(6):061712

Australian Clinical Dosimetry Service, 619 Lower Plenty Road, Yallambie, VIC 3085, Australia and School of Applied Sciences, Royal Melbourne Institute of Technology (RMIT) University, GPO Box 2476, Melbourne, VIC 3000, Australia.

Purpose: The purpose of this investigation was to assess the angular dependence of a commercial optically stimulated luminescence dosimeter (OSLD) dosimetry system in MV x-ray beams at depths beyond d(max) and to find ways to mitigate this dependence for measurements in phantoms.

Methods: Two special holders were designed which allow a dosimeter to be rotated around the center of its sensitive volume. The dosimeter's sensitive volume is a disk, 5 mm in diameter and 0.2 mm thick. The first holder rotates the disk in the traditional way. It positions the disk perpendicular to the beam (gantry pointing to the floor) in the initial position (0°). When the holder is rotated the angle of the disk towards the beam increases until the disk is parallel with the beam ("edge on," 90°). This is referred to as Setup 1. The second holder offers a new, alternative measurement position. It positions the disk parallel to the beam for all angles while rotating around its center (Setup 2). Measurements with five to ten dosimeters per point were carried out for 6 MV at 3 and 10 cm depth. Monte Carlo simulations using GEANT4 were performed to simulate the response of the active detector material for several angles. Detector and housing were simulated in detail based on microCT data and communications with the manufacturer. Various material compositions and an all-water geometry were considered.

Results: For the traditional Setup 1 the response of the OSLD dropped on average by 1.4% ± 0.7% (measurement) and 2.1% ± 0.3% (Monte Carlo simulation) for the 90° orientation compared to 0°. Monte Carlo simulations also showed a strong dependence of the effect on the composition of the sensitive layer. Assuming the layer to completely consist of the active material (Al2O3) results in a 7% drop in response for 90° compared to 0°. Assuming the layer to be completely water, results in a flat response within the simulation uncertainty of about 1%. For the new Setup 2, measurements and Monte Carlo simulations found the angular dependence of the dosimeter to be below 1% and within the measurement uncertainty.

Conclusions: The dosimeter system exhibits a small angular dependence of approximately 2% which needs to be considered for measurements involving other than normal incident beams angles. This applies in particular to clinical in vivo measurements where the orientation of the dosimeter is dictated by clinical circumstances and cannot be optimized as otherwise suggested here. When measuring in a phantom, the proposed new setup should be considered. It changes the orientation of the dosimeter so that a coplanar beam arrangement always hits the disk shaped detector material from the thin side and thereby reduces the angular dependence of the response to within the measurement uncertainty of about 1%. This improvement makes the dosimeter more attractive for clinical measurements with multiple coplanar beams in phantoms, as the overall measurement uncertainty is reduced. Similarly, phantom based postal audits can transition from the traditional TLD to the more accurate and convenient OSLD.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.4875698DOI Listing
June 2014

Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters.

Med Phys 2014 Mar;41(3):032102

Australian Clinical Dosimetry Service, Yallambie, Victoria 3085, Australia and School of Applied Science, RMIT University, Melbourne 3000, Australia.

Purpose: On 1 July 2012, the Australian Clinical Dosimetry Service (ACDS) released its Optically Stimulated Luminescent Dosimeter (OSLD) Level I audit, replacing the previous TLD based audit. The aim of this work is to present the results from this new service and the complete uncertainty analysis on which the audit tolerances are based.

Methods: The audit release was preceded by a rigorous evaluation of the InLight® nanoDot OSLD system from Landauer (Landauer, Inc., Glenwood, IL). Energy dependence, signal fading from multiple irradiations, batch variation, reader variation, and dose response factors were identified and quantified for each individual OSLD. The detectors are mailed to the facility in small PMMA blocks, based on the design of the existing Radiological Physics Centre audit. Modeling and measurement were used to determine a factor that could convert the dose measured in the PMMA block, to dose in water for the facility's reference conditions. This factor is dependent on the beam spectrum. The TPR20,10 was used as the beam quality index to determine the specific block factor for a beam being audited. The audit tolerance was defined using a rigorous uncertainty calculation. The audit outcome is then determined using a scientifically based two tiered action level approach. Audit outcomes within two standard deviations were defined as Pass (Optimal Level), within three standard deviations as Pass (Action Level), and outside of three standard deviations the outcome is Fail (Out of Tolerance).

Results: To-date the ACDS has audited 108 photon beams with TLD and 162 photon beams with OSLD. The TLD audit results had an average deviation from ACDS of 0.0% and a standard deviation of 1.8%. The OSLD audit results had an average deviation of -0.2% and a standard deviation of 1.4%. The relative combined standard uncertainty was calculated to be 1.3% (1σ). Pass (Optimal Level) was reduced to ≤2.6% (2σ), and Fail (Out of Tolerance) was reduced to >3.9% (3σ) for the new OSLD audit. Previously with the TLD audit the Pass (Optimal Level) and Fail (Out of Tolerance) were set at ≤4.0% (2σ) and >6.0% (3σ).

Conclusions: The calculated standard uncertainty of 1.3% at one standard deviation is consistent with the measured standard deviation of 1.4% from the audits and confirming the suitability of the uncertainty budget derived audit tolerances. The OSLD audit shows greater accuracy than the previous TLD audit, justifying the reduction in audit tolerances. In the TLD audit, all outcomes were Pass (Optimal Level) suggesting that the tolerances were too conservative. In the OSLD audit 94% of the audits have resulted in Pass (Optimal level) and 6% of the audits have resulted in Pass (Action Level). All Pass (Action level) results have been resolved with a repeat OSLD audit, or an on-site ion chamber measurement.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.4865786DOI Listing
March 2014

The Australian Clinical Dosimetry Service: a commentary on the first 18 months.

Australas Phys Eng Sci Med 2012 Dec 28;35(4):407-11. Epub 2012 Sep 28.

Australian Clinical Dosimetry Service, ARPANSA, Australia.

View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1007/s13246-012-0161-1DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3562435PMC
December 2012

On using 3D γ-analysis for IMRT and VMAT pretreatment plan QA.

Med Phys 2012 Jun;39(6):3051-9

Radiation Oncology Centers (ROC), Radiological Associates of Sacramento (RAS), Sacramento, CA 95815, USA.

Purpose: To investigate using 3D γ analysis for IMRT and VMAT QA.

Methods: We explored and studied 3D γ-analysis by comparing TPS computed and EPID back-projection reconstructed doses in patient's CT images. Two 3D γ quantities, γ(PTV) and γ(10), were proposed and studied for evaluating the QA results, and compared to 2D γ (MapCheck composite: γ(MC)).

Results: It was found that when 3%(global)/3 mm criteria was used, all IMRT and 90% of VMAT plans passed QA with a γ pass rate ≥90%. A significant statistical correlation was observed between 3D and 2D γ-analysis results for IMRT QA if γ(10) and γ(MC) are concerned, but no significant relation is found between γ(PTV) and γ(MC).

Conclusions: 3D γ analysis based on EPID dose back-projection may provide a feasible tool for IMRT and VMAT pretreatment plan QA.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.4711755DOI Listing
June 2012

Quality assurance for nonradiographic radiotherapy localization and positioning systems: report of Task Group 147.

Med Phys 2012 Apr;39(4):1728-47

Task Group 147, Department of Radiation Physics, Orlando, FL, USA.

New technologies continue to be developed to improve the practice of radiation therapy. As several of these technologies have been implemented clinically, the Therapy Committee and the Quality Assurance and Outcomes Improvement Subcommittee of the American Association of Physicists in Medicine commissioned Task Group 147 to review the current nonradiographic technologies used for localization and tracking in radiotherapy. The specific charge of this task group was to make recommendations about the use of nonradiographic methods of localization, specifically; radiofrequency, infrared, laser, and video based patient localization and monitoring systems. The charge of this task group was to review the current use of these technologies and to write quality assurance guidelines for the use of these technologies in the clinical setting. Recommendations include testing of equipment for initial installation as well as ongoing quality assurance. As the equipment included in this task group continues to evolve, both in the type and sophistication of technology and in level of integration with treatment devices, some of the details of how one would conduct such testing will also continue to evolve. This task group, therefore, is focused on providing recommendations on the use of this equipment rather than on the equipment itself, and should be adaptable to each user's situation in helping develop a comprehensive quality assurance program.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.3681967DOI Listing
April 2012
-->