Publications by authors named "Irfan Muhammad Rajput"

3 Publications

  • Page 1 of 1

Impact of Ilizarov Fixation Technique on the Limb Functionality and Self-esteem of Patients with Unilateral Tibial Fractures.

Cureus 2019 Oct 16;11(10):e5923. Epub 2019 Oct 16.

Orthopaedic Surgery, Dow University of Health Sciences/ Dr. Ruth KM Pfau Civil Hospital, Karachi, PAK.

Introduction Tibial fractures with nonunion are frequently managed with Ilizarov external fixation. Living with an external frame has some psychological impact which is readily neglected from the literature. We conducted a study to evaluate the status of limb functionality in patients managed with the Ilizarov external ring fixator technique and assess their self-esteem while living with the frame. Materials and methods This is a prospective observational study conducted in the Orthopedic Department of Dr. Ruth KM Phau Civil Hospital, Karachi, Pakistan, from June 2018 to June 2019. A total of 26 patients consecutively managed with Ilizarov external fixation for infected nonunion, with unilateral tibial fractures, were included. To assess the postoperative functionality status, lower extremity functional scale (LEFS) was used. To assess and evaluate the impact of the external frame application on the self-esteem of these patients, Rosenberg's self-esteem (RSE) scale was used. For each patient, LEFS and RSE scales were administered at the time of hospital discharge, after six months of frame application, and at the time of removal of the frame. Results The mean duration of hospital stay was 4.11 ± 1.23 weeks. The mean LEFS scores increased by 47% from hospital discharge until the time of frame removal. The differences were highly significant ( < 0.001). There was a 12% decline in the mean score of self-esteem from the time of discharge till the time of removal of the Ilizarov frame and these differences were highly significant ( < 0.001). Conclusion Ilizarov technique improves the limb functionality status significantly in participants with a unilateral tibial fracture. However, it also reduces their self-esteem during the period of frame application. Psychological support is recommended for participants living with an external fixation frame to protect their self-esteem.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.7759/cureus.5923DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6857830PMC
October 2019

Surgical Fixation of Atypical Femur Fractures in Bisphosphonate-treated Patients.

Cureus 2019 May 17;11(5):e4690. Epub 2019 May 17.

Orthopaedic Surgery, Dow Medical College Karachi, Karachi, PAK.

Objective To evaluate the outcomes of the surgical fixation of atypical femoral fractures in bisphosphonate-treated patients with an intramedullary device. Materials and methods This multicentric study was carried out at the department of orthopedics, Dr. Ruth Phau Civil Hospital and Medicare Hospital, Karachi, Pakistan, between 2013 and 2018. In this retrospective observational study, we reviewed 10 bisphosphonate-treated patients, fixed surgically with an intramedullary nail after presenting with radiologically characteristic atypical femur fractures identified according to the American Society for Bone and Mineral Research criteria. We excluded patients with fractures sustained by high-energy trauma, road traffic accidents, fall from a height, and those associated with underlying malignancy. Results A total of 11 atypical femoral fractures in 10 patients were included, all of whom were females with a mean age of 68.6 (range 57-82) years. Out of 11 fractures, 81.8% (n=9) were located in the subtrochanteric region and two were located in the femoral shaft. The mean bisphosphonate use was 58.3 months. All patients were treated with intramedullary devices; an intramedullary interlocking nail in two cases and proximal femoral nail antirotation in nine cases. The mean follow-up duration was 12 months. All fractures were united in an average time of 9.9 months (range 6 - 16 months). Implant failure and/or nonunion were not observed, whereas delayed union was noted in five patients. Conclusion Intramedullary fixation is a reliable method for the treatment of atypical femur fractures in bisphosphonate-treated patients owing to its intramedullary placement. These devices act as an internal splint and can provide much more axial stability, reducing the risk of implant fatigue failure due to a delay in fracture healing from prolonged bisphosphonate use.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.7759/cureus.4690DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6636699PMC
May 2019

Outcome of Percutaneous Release for Trigger Digits in Diabetic and Non-diabetic Patients.

Cureus 2019 May 2;11(5):e4585. Epub 2019 May 2.

Orthopaedics, Dow University of Health Sciences, Karachi, PAK.

Introduction Trigger finger (TF) is a common cause of hand pain, swelling, and limited motion. It is common in women and in the thumb. Diabetes mellitus (DM) increases the risk of TF. Individuals with DM who develop TF are resistant to both medical and surgical interventions. The aim of this study is to compare the outcomes of percutaneous trigger release in diabetic and nondiabetic patients. Methods Fifty diabetic and 50 non-diabetic patients with a clinical diagnosis of TF were included after informed consent. Percutaneous trigger release was performed in all of them. Follow-ups for pain and/or neurovascular complications were taken after one week, one month, and six months. Data were entered and analyzed using SPSS v. 22 (IBM Corp., Armonk, NY, US). Results In the diabetic group, 86% of patients had TF of grade III or above and in the non-diabetic group, 76% of patients had TF of grade III or above. At the one-week follow-up, 79.2% diabetic patients still had mild to severe pain and 60.4% non-diabetic patients had mild to severe pain. By one month, 40% patients in the diabetic group still reported mild to moderate pain, however, all patients in the non-diabetic group reported no pain. By six months, nine (20%) diabetic patients reported mild pain. There was no incidence of infection or neurovascular damage at any follow-up in the non-diabetic group, and in the diabetic group, 4.2% of patients had an infection on the one-week follow-up. Conclusion Percutaneous trigger finger release is a safe, reliable, time-saving, and cost-effective procedure for the management of trigger finger in both diabetic and non-diabetic patients.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.7759/cureus.4585DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6609281PMC
May 2019
-->