Publications by authors named "Harry S Hothi"

25Publications

Metal-on-metal total hip arthroplasty: does increasing modularity affect clinical outcome?

Hip Int 2020 Dec 16:1120700020979275. Epub 2020 Dec 16.

Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, UK.

View Article and Find Full Text PDF
December 2020

Does modularity of metal-on-metal hip implants increase cobalt: chromium ratio?

Hip Int 2021 Jan 8;31(1):109-114. Epub 2019 Sep 8.

Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, Middlesex, UK.

View Article and Find Full Text PDF
January 2021

Assessment of material loss of retrieved magnetically controlled implants for limb lengthening.

Proc Inst Mech Eng H 2018 Nov 11;232(11):1129-1136. Epub 2018 Oct 11.

1 Institute of Orthopaedics and Musculoskeletal Science, Research Department of Materials and Tissue, University College London, Stanmore, UK.

View Article and Find Full Text PDF
November 2018

Retrieval Findings of Recalled Dual-Taper Hips.

J Bone Joint Surg Am 2018 Oct;100(19):1661-1672

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.

View Article and Find Full Text PDF
October 2018

Computed Tomography Techniques Help Understand Wear Patterns in Retrieved Total Knee Arthroplasty.

J Arthroplasty 2018 09 16;33(9):3030-3037. Epub 2018 Apr 16.

Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore, UK.

View Article and Find Full Text PDF
September 2018

Effect of Bearing Type on Taper Material Loss in Hips From 1 Manufacturer.

J Arthroplasty 2018 05 29;33(5):1588-1593. Epub 2017 Dec 29.

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.

View Article and Find Full Text PDF
May 2018

The Chemical Form of Metal Species Released from Corroded Taper Junctions of Hip Implants: Synchrotron Analysis of Patient Tissue.

Sci Rep 2017 09 8;7(1):10952. Epub 2017 Sep 8.

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.

View Article and Find Full Text PDF
September 2017

Analysing a mechanism of failure in retrieved magnetically controlled spinal rods.

Eur Spine J 2017 06 19;26(6):1699-1710. Epub 2017 Jan 19.

Institute of Orthopaedics and Musculoskeletal Science, Royal National Orthopaedic Hospital, University College London, Brockley Hill, Stanmore, Middlesex, HA7 4LP, UK.

View Article and Find Full Text PDF
June 2017

Response to Letter to the Editor on "Factors Associated With Trunnionosis in the Metal-on-Metal Pinnacle Hip".

Authors:
Harry S Hothi

J Arthroplasty 2017 03 30;32(3):1044-1045. Epub 2016 Sep 30.

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.

View Article and Find Full Text PDF
March 2017

Inflammatory cell-induced corrosion in total knee arthroplasty: A retrieval study.

J Biomed Mater Res B Appl Biomater 2018 Jan 29;106(1):460-467. Epub 2016 Nov 29.

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.

View Article and Find Full Text PDF
January 2018

Clinical significance of corrosion of cemented femoral stems in metal-on-metal hips: a retrieval study.

Int Orthop 2016 Nov 25;40(11):2247-2254. Epub 2016 Jan 25.

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex, HA7 4LP, UK.

View Article and Find Full Text PDF
November 2016

Variation in taper surface roughness for a single design effects the wear rate in total hip arthroplasty.

J Orthop Res 2017 08 25;35(8):1784-1792. Epub 2016 Oct 25.

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, London, HA7 4LP, United Kingdom.

View Article and Find Full Text PDF
August 2017

Clinical Cold Welding of the Modular Total Hip Arthroplasty Prosthesis.

J Arthroplasty 2017 02 10;32(2):610-615. Epub 2016 Aug 10.

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, London, United Kingdom.

View Article and Find Full Text PDF
February 2017

Damage Patterns at the Head-Stem Taper Junction Helps Understand the Mechanisms of Material Loss.

J Arthroplasty 2017 01 7;32(1):291-295. Epub 2016 Jul 7.

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.

View Article and Find Full Text PDF
January 2017

Factors Associated With Trunnionosis in the Metal-on-Metal Pinnacle Hip.

J Arthroplasty 2017 01 29;32(1):286-290. Epub 2016 Jun 29.

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.

View Article and Find Full Text PDF
January 2017

The Relationship Between Cobalt/Chromium Ratios and the High Prevalence of Head-Stem Junction Corrosion in Metal-on-Metal Total Hip Arthroplasty.

J Arthroplasty 2016 05 26;31(5):1123-7. Epub 2015 Nov 26.

Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore, United Kingdom.

View Article and Find Full Text PDF
May 2016

Clinical relevance of corrosion patterns attributed to inflammatory cell-induced corrosion: A retrieval study.

J Biomed Mater Res B Appl Biomater 2017 01 6;105(1):155-164. Epub 2015 Oct 6.

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.

View Article and Find Full Text PDF
January 2017

Detailed inspection of metal implants.

Hip Int 2015 May-Jun;25(3):227-31. Epub 2015 Apr 24.

1 Institute of Orthopaedics and Musculoskeletal Science, Stanmore - UK.

View Article and Find Full Text PDF
March 2016

Corrosion of Metal Modular Cup Liners.

J Arthroplasty 2015 Sep 31;30(9):1652-6. Epub 2015 Mar 31.

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.

View Article and Find Full Text PDF
September 2015

Influence of stem type on material loss at the metal-on-metal pinnacle taper junction.

Proc Inst Mech Eng H 2015 Jan;229(1):91-7

Institute of Orthopaedics and Musculoskeletal Science, University College London and Royal National Orthopaedic Hospital, Stanmore, UK.

View Article and Find Full Text PDF
January 2015

Component size mismatch of metal on metal hip arthroplasty: an avoidable never event.

J Arthroplasty 2014 Aug 13;29(8):1629-34. Epub 2014 Mar 13.

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.

View Article and Find Full Text PDF
August 2014

The reliability of a scoring system for corrosion and fretting, and its relationship to material loss of tapered, modular junctions of retrieved hip implants.

J Arthroplasty 2014 Jun 10;29(6):1313-7. Epub 2013 Dec 10.

Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.

View Article and Find Full Text PDF
June 2014

Deformation of uncemented metal acetabular cups following impaction: experimental and finite element study.

Comput Methods Biomech Biomed Engin 2014 14;17(11):1261-74. Epub 2012 Dec 14.

a School of Engineering and Materials Science, Queen Mary University of London , London , UK.

View Article and Find Full Text PDF
August 2014