Mechatronic Design of a Two-Arm Concentric Tube Robot System for Rigid Neuroendoscopy.

IEEE ASME Trans Mechatron 2020 Jun 27;25(3):1432-1443. Epub 2020 Feb 27.

Department of Mechanical Engineering at Vanderbilt University, Nashville, TN 37235, USA.

Open surgical approaches are still often employed in neurosurgery, despite the availability of neuroendoscopic approaches that reduce invasiveness. The challenge of maneuvering instruments at the tip of the endoscope makes neuroendoscopy demanding for the physician. The only way to aim tools passed through endoscope ports is to tilt the entire endoscope; but, tilting compresses brain tissue through which the endoscope passes and can damage it. Concentric tube robots can provide necessary dexterity without endoscope tilting, while passing through existing ports in the endoscope and carrying surgical tools in their inner lumen. In this paper we describe the mechatronic design of a new concentric tube robot that can deploy two concentric tube manipulators through a standard neuroendoscope. The robot uses a compact differential drive and features embedded motor control electronics and redundant position sensors for safety. In addition to the mechatronic design of this system, this paper contributes experimental validation in the context of colloid cyst removal, comparing our new robotic system to standard manual endoscopy in a brain phantom. The robotic approach essentially eliminated endoscope tilt during the procedure (17.09° for the manual approach vs. 1.16° for the robotic system). The robotic system also enables a single surgeon to perform the procedure - typically in a manual approach one surgeon aims the endoscope and another operates the tools delivered through its ports.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1109/tmech.2020.2976897DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7971161PMC
June 2020

Transurethral Anastomosis after Transurethral Radical Prostatectomy: A Phantom Study on Intraluminal Suturing With Concentric Tube Robots.

IEEE Trans Med Robot Bionics 2020 Nov 29;2(4):578-581. Epub 2020 Oct 29.

Department of Mechanical Engineering, Vanderbilt University.

Current surgical approaches to radical prostatectomy are associated with high rates of erectile dysfunction and incontinence. These complications occur secondary to the disruption of surrounding healthy tissue, which is required to expose the prostate. The urethra offers the least invasive access to the prostate, and feasibility has been demonstrated of enucleating the prostate with an endoscope using Holmium laser, which can itself be aimed by concentric tube robots. However, the transurethral approach to radical prostatectomy has thus far been limited by the lack of a suitable means to perform an anastomosis of the urethra to the bladder after prostate removal. Only a few intraluminal anastomotic devices currently exist, and none are small enough to pass through the urethra. In this paper we describe a new way to perform an anastomosis in the small luminal space of the urethra, harnessing the dexterity and customizability of concentric tube manipulators. We demonstrate a successful initial proof-of-concept anastomosis in an anthropomorphic phantom of the urethra and bladder.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1109/tmrb.2020.3034735DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7694552PMC
November 2020

A Novel Robotic Endoscopic Device Used for Operative Hysteroscopy.

J Minim Invasive Gynecol 2020 Nov - Dec;27(7):1631-1635. Epub 2020 Jun 12.

Division of Minimally Invasive Gynecology, Department of Obstetrics and Gynecology, Vanderbilt University Medical Center (Drs. Harvey, R. J. Webster, and Anderson).

To trial the use of a novel endoscopic robot that functions using concentric tube robots, enabling 2-handed surgery in small spaces, in a bioengineering laboratory. This was a feasibility study of the endoscopic robot for hysteroscopic applications, including removal of a simulated endometrial polyp. The endoscopic robot was successfully used to resect a simulated endometrial polyp from a porcine uterine tissue model in a fluid environment. The potential advantages of this platform to the surgeon may include improved exposure, finer dissection capability, and use of a 2-handed surgical technique. Further study regarding the safe, efficient, and cost-effective use of the endoscopic robot in gynecology is needed.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmig.2020.06.009DOI Listing
February 2021

A Concentric Tube Robot System for Rigid Bronchoscopy: A Feasibility Study on Central Airway Obstruction Removal.

Ann Biomed Eng 2020 Jan 24;48(1):181-191. Epub 2019 Jul 24.

Mechanical Engineering Department, Vanderbilt University, Nashville, TN, USA.

New robotic systems have recently emerged to assist with peripheral lung access, but a robotic system for rigid bronchoscopy has yet to be developed. We describe a new robotic system that can deliver thin robotic manipulators through the ports of standard rigid bronchoscopes. The manipulators bend and elongate to provide maneuverability of surgical tools at the endoscope tip, without endoscope motion. We describe an initial feasibility study on the use of this system to bronchoscopically treat a central airway obstruction (CAO). CAO is prevalent and can be life-threatening in patients with large tumors, and conventional rigid bronchoscopic treatments place patients at risk of complications including broken teeth, neck trauma and damage to oropharyngeal structures due to significant forces induced by bronchoscope tilting and manipulation. In this study, we used an ex vivo ovine airway model to demonstrate the ability of a physician using the robotic system to efficiently remove tissue and restore the airway. Pre- and post-operative CT scans showed that the robot was able to reduce the degree of airway obstruction stenosis from 75 to 14% on average for five CAO resections performed in an ex vivo animal model. Using cadaver experiments, we demonstrated the potential of the robotic system to substantially reduce the intraoperative forces applied to the patient's head and neck (from 80.6 to 4.1 N). These preliminary results illustrate that CAO removal is feasible with our new rigid bronchoscopy robot system, and that this approach has the potential to reduce forces applied to the patient due to bronchoscope angulation, and thereby reduce the risk of complications encountered during CAO surgery.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10439-019-02325-xDOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6930337PMC
January 2020
-->