Publications by authors named "Denis R Santos"

2 Publications

  • Page 1 of 1

Silica bead-based microfluidic device with integrated photodiodes for the rapid capture and detection of rolling circle amplification products in the femtomolar range.

Biosens Bioelectron 2019 Mar 18;128:68-75. Epub 2018 Dec 18.

Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, SE-171 65 Solna, Sweden. Electronic address:

The rapid and sensitive detection of specific nucleic acid sequences at the point-of-care (PoC) is becoming increasingly in demand for a variety of emergent biomedical applications ranging from infectious disease diagnostics to the screening of antimicrobial resistance. To meet such demand, considerable efforts have been invested towards the development of portable and integrated analytical devices combining microfluidics with miniaturized signal transducers. Here, we demonstrate the combination of rolling circle amplification (RCA)-based nucleic acid amplification with an on-chip size-selective trapping of amplicons on silica beads (~8 nL capture chamber) coupled with a thin-film photodiode (200 × 200 µm area) fluorescence readout. Parameters such as the flow rate of the amplicon solution and trapping time were optimized as well as the photodiode measurement settings, providing minimum detection limits below 0.5 fM of targeted nucleic acids and requiring only 5 μL of pre-amplified sample. Finally, we evaluated the analytical performance of our approach by benchmarking it against a commercial instrument for RCA product (RCP) quantification and further investigated the effect of the number of RCA cycles and elongation times (ranging from 10 to 120 min). Moreover, we provide a demonstration of the application for diagnostic purposes by detecting RNA from influenza and Ebola viruses, thus highlighting its suitability for integrated PoC systems.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2018.12.004DOI Listing
March 2019

Multiplexed microfluidic fluorescence immunoassay with photodiode array signal acquisition for sub-minute and point-of-need detection of mycotoxins.

Lab Chip 2018 05;18(11):1569-1580

Instituto de Engenharia de Sistemas e Computadores - Microsistemas e Nanotecnologias (INESC MN) and IN - Institute of Nanoscience and Nanotechnology, Lisbon, Portugal.

Portable, rapid, cost effective and simple analytical tools are in increasing demand to facilitate the routine monitoring of target chemical/biological compounds at the point-of-need. Such devices are highly relevant within the context of food safety, particularly concerning the screening of highly toxic and strictly regulated mycotoxins. To achieve ultrarapid detection of mycotoxins, namely aflatoxin B1, ochratoxin A and deoxynivalenol, at the point-of-need, a novel multiplexed bead-based microfluidic competitive immunosensor, coupled with an array of a-Si:H thin-film photodiodes for integrated fluorescence signal acquisition, is reported. Simultaneously measuring the initial binding rate for each analyte of the sample under analysis against an internal reference, this device provided limits of detection below 1 ng mL-1 for all mycotoxins in a single-step assay and within 1 minute after mixing the sample under analysis with a fluorescent conjugate. The compatibility of the device with the analysis of mycotoxins spiked in corn samples was further demonstrated after performing a sample preparation procedure based on aqueous two-phase extraction. The short times of analysis and sensitivities in the low ng mL-1 range make these devices potentially competitive with the lateral flow devices that are currently the standard for this application. Furthermore, this device architecture and concept is amenable of being expanded to other analytes in food safety, biomedical and other applications.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1039/c8lc00259bDOI Listing
May 2018
-->