David A Berntsen

David A Berntsen

UNVERIFIED PROFILE

Are you David A Berntsen?   Register this Author

Register author
David A Berntsen

David A Berntsen

Publications by authors named "David A Berntsen"

Are you David A Berntsen?   Register this Author

36Publications

310Reads

44Profile Views

Optical changes and visual performance with orthokeratology.

Clin Exp Optom 2020 Jan 4;103(1):44-54. Epub 2019 Aug 4.

The Ocular Surface Institute, College of Optometry, University of Houston, Houston, Texas, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1111/cxo.12947DOI Listing
January 2020

A Randomized Trial to Evaluate the Effect of Toric Versus Spherical Contact Lenses on Vision and Eyestrain.

Eye Contact Lens 2019 Jan;45(1):28-33

The Ocular Surface Institute (D.A.B., D.R.P.), University of Houston College of Optometry, Houston, TX; University of Alabama at Birmingham School of Optometry (S.M.C., J.J.N.), Birmingham, AL; The Ohio State University College of Optometry (K.M.B.), Columbus, OH; Alcon Laboratories (J.H.M.), Fort Worth, TX; Department of Biomedical Engineering (S.H.S.), University of Rochester, Rochester, NY; and Johnson & Johnson Vision Care, Inc (B.K.L., K.O.L.), Jacksonville, FL.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICL.0000000000000528DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6319569PMC
January 2019

Efficacy of Toric Contact Lenses in Fitting and Patient-Reported Outcomes in Contact Lens Wearers.

Eye Contact Lens 2018 Sep;44 Suppl 1:S296-S299

University of Alabama at Birmingham School of Optometry (S.M.C., J.J.N.), Birmingham, AL; The Ohio State University College of Optometry (K.M.B.), Columbus, OH; The Ocular Surface Institute (D.A.B., J.H.M., D.R.P.), University of Houston College of Optometry, Houston, TX; and Johnson & Johnson Vision Care, Inc (B.K.L., K.O.L.), Jacksonville, FL.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICL.0000000000000418DOI Listing
September 2018

Low-Dose Atropine for Myopia Control: Considering All the Data.

JAMA Ophthalmol 2018 03;136(3):303

College of Optometry, University of Houston, Houston, Texas.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1001/jamaophthalmol.2017.6638DOI Listing
March 2018

Aberrometry Repeatability and Agreement with Autorefraction.

Optom Vis Sci 2017 09;94(9):886-893

The Ocular Surface Institute, University of Houston College of Optometry, Houston, Texas.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000001107DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5578873PMC
September 2017

A Randomized Trial of Soft Multifocal Contact Lenses for Myopia Control: Baseline Data and Methods.

Optom Vis Sci 2017 09;94(9):856-866

1The Ohio State University College of Optometry, Columbus, Ohio 2University of Houston College of Optometry, Houston, Texas.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000001106DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5607949PMC
September 2017

Spherical Soft Contact Lens Designs and Peripheral Defocus in Myopic Eyes.

Optom Vis Sci 2017 03;94(3):370-379

*OD, MS †PhD ‡OD, PhD, FAAO The Ocular Surface Institute, College of Optometry (KEM, DAB), and College of Optometry & Texas Institute for Measurement, Evaluation, and Statistics (TIMES) (JSB), University of Houston, Houston, Texas.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000001053DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5324711PMC
March 2017

Validation of Macular Choroidal Thickness Measurements from Automated SD-OCT Image Segmentation.

Optom Vis Sci 2016 11;93(11):1387-1398

*OD, PhD, FAAO †OD, FAAO ‡PhD School of Optometry (MDT), Department of Biomedical Engineering (MDT), University of Alabama at Birmingham, Birmingham, Alabama; College of Optometry, University of Houston, Houston, Texas (KLS, DAB); Department of Biomedical Engineering, Duke University, Durham, North Carolina (SJC, SF); and Department of Ophthalmology, Duke University Medical Center, Durham, North Carolina (SF).

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000000985DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5108587PMC
November 2016

Microbial Contamination of Contact Lens Storage Cases During Daily Wear Use.

Optom Vis Sci 2016 08;93(8):925-32

*PhD, BOptom †PhD ‡PhD, PGCertOcTher, FAAO §MSc, MCOptom ∥PhD, OD, FAAO **PhD, MCOptom, FAAO ††OD, PhD, MPH, FAAO Centre for Contact Lens Research, School of Optometry & Vision Science, University of Waterloo, Ontario, Canada (JD, DJM, LNS, DP, LWJ); Johnson & Johnson Vision Care, Jacksonville, Florida (CL); Eurolens Research, University of Manchester, Manchester, United Kingdom (AM, PM); The Ocular Surface Institute, College of Optometry, University of Houston, Houston, Texas (DAB); and School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama (JJN).

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000000886DOI Listing
August 2016

Eyelid Margin and Meibomian Gland Characteristics and Symptoms in Lens Wearers.

Optom Vis Sci 2016 08;93(8):901-8

*OD, FAAO †OD, PhD, FAAO ‡BSc, MSc, MCOptom §BSc, MCOptom, FAAO ∥PhD, FCOptom, FAAO **MSc, BOptom ††BSc, PhD, MCOptom, FAAO ‡‡OD, MPH, PhD, FAAO The University of Alabama at Birmingham, School of Optometry, Birmingham, Alabama (SMC, JJN); The Ocular Surface Institute, College of Optometry, University of Houston, Houston, Texas (DAB); Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, Manchester, United Kingdom (NC, PBM); Johnson & Johnson Vision Care, Inc., Jacksonville, Florida (SBH-C); and Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada (LWJ, AMM).

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000000900DOI Listing
August 2016

Subjective Comfort and Physiology with Modern Contact Lens Care Products.

Optom Vis Sci 2016 08;93(8):809-19

*OD, PhD, FAAO †BSc(Hons), MCOptom, FAAO ‡PhD, FCOptom, FAAO §PhD, MCOptom, FAAO ∥BSc(Hons), PhD, MCOptom, FAAO **PhD, Dipl Ing (AO), FAAO ††OD, MPH, PhD, FAAO The Ocular Surface Institute, College of Optometry, University of Houston, Texas (DAB, JHM); Johnson & Johnson Vision Care, Inc., Jacksonville, Florida (SBH-C); Centre for Contact Lens Research, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada (LWJ, MMS); Eurolens Research, Faculty of Life Sciences, University of Manchester, United Kingdom (CM-C, PBM); and School of Optometry, University of Alabama at Birmingham, Alabama (JJN).

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000000901DOI Listing
August 2016

Lid Wiper Epitheliopathy in Soft Contact Lens Wearers.

Optom Vis Sci 2016 08;93(8):943-54

*DiplIng(AO), PhD, FAAO †BSOptom, PhD, FAAO ‡BSc, MCOptom, FAAO §OD, PhD, FAAO ∥BSc(Hons), MCOptom **MSc ††BSc(Hons), PhD, MCOptom FAAO ‡‡OD, MPH, PhD, FAAO §§PhD, FCOptom, FAAO Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada (M-MS, SS, LWJ); Johnson and Johnson Vision Care, Inc., Jacksonville, Florida (SBH-C, YT); The Ocular Surface Institute, College of Optometry, University of Houston, Houston, Texas (DAB); Eurolens Research, University of Manchester, Manchester, United Kingdom (GFH, PM); and School of Optometry, The University of Alabama at Birmingham, Birmingham, Alabama (JJN).

View Article

Download full-text PDF

Source
http://content.wkhealth.com/linkback/openurl?sid=WKPTLP:land
Publisher Site
http://dx.doi.org/10.1097/OPX.0000000000000919DOI Listing
August 2016

Impact of Lens Care Solutions on Protein Deposition on Soft Contact Lenses.

Optom Vis Sci 2016 08;93(8):963-72

*PhD, BOptom †MSc ‡PhD, BSOptom, FAAO §PhD ∥PhD, BScOptom, PGCertOcTher, FAAO **MCOptom, BSc(Hons) ††PhD, MCOptom, FAAO ‡‡OD, PhD, FAAO §§OD, PhD, MPH, FAAO ∥∥PhD, FCOptom, FAAO Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Ontario, Canada (NBO, MH, LNS, DP, LWJ); Johnson and Johnson Vision Care, Inc., Jacksonville, Florida (CL); Eurolens Research, University of Manchester, Manchester, United Kingdom (SLS, PBM); The Ocular Surface Institute, College of Optometry, University of Houston, Houston, Texas (DAB); and School of Optometry, University of Alabama, Birmingham, Birmingham, Alabama (JJN).

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000000928DOI Listing
August 2016

Central and peripheral autorefraction repeatability in normal eyes.

Optom Vis Sci 2014 Sep;91(9):1106-12

*BS †OD, PhD, FAAO University of Houston, College of Optometry, Houston, Texas (both authors).

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000000351DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4142103PMC
September 2014

Peripheral defocus with spherical and multifocal soft contact lenses.

Optom Vis Sci 2013 Nov;90(11):1215-24

*OD, PhD, FAAO †BA College of Optometry, University of Houston, Houston, Texas.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000000066DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3932782PMC
November 2013

Peripheral defocus and myopia progression in myopic children randomly assigned to wear single vision and progressive addition lenses.

Invest Ophthalmol Vis Sci 2013 Aug 27;54(8):5761-70. Epub 2013 Aug 27.

University of Houston College of Optometry, Houston, Texas 77204-2020, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1167/iovs.13-11904DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3755539PMC
August 2013

Repeatability of on- and off-axis eye length measurements using the lenstar.

Optom Vis Sci 2013 Jan;90(1):16-22

University of Houston, College of Optometry, Houston, Texas 77204-2020, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0b013e3182780bfdDOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3534894PMC
January 2013

A randomized trial using progressive addition lenses to evaluate theories of myopia progression in children with a high lag of accommodation.

Invest Ophthalmol Vis Sci 2012 Feb 13;53(2):640-9. Epub 2012 Feb 13.

University of Houston, College of Optometry, Houston, Texas 77204-2020, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1167/iovs.11-7769DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3317412PMC
February 2012

Accommodative lag and juvenile-onset myopia progression in children wearing refractive correction.

Vision Res 2011 May 20;51(9):1039-46. Epub 2011 Feb 20.

University of Houston College of Optometry, Houston, TX, United States.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.visres.2011.02.016DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3111954PMC
May 2011

The effect of bifocal add on accommodative lag in myopic children with high accommodative lag.

Invest Ophthalmol Vis Sci 2010 Dec 4;51(12):6104-10. Epub 2010 Aug 4.

Ohio State University College of Optometry, Columbus, Ohio, USA.

View Article

Download full-text PDF

Source
http://iovs.arvojournals.org/article.aspx?doi=10.1167/iovs.0
Publisher Site
http://dx.doi.org/10.1167/iovs.09-4417DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3055747PMC
December 2010

Study of Theories about Myopia Progression (STAMP) design and baseline data.

Optom Vis Sci 2010 Nov;87(11):823-32

College of Optometry, The Ohio State University, Columbus, Ohio, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0b013e3181f6f776DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3075061PMC
November 2010

Purchase of contact lenses and contact-lenses-related symptoms following the Contact Lenses in Pediatrics (CLIP) Study.

Cont Lens Anterior Eye 2009 Aug 1;32(4):157-63. Epub 2009 May 1.

The Ohio State University College of Optometry, Columbus, OH 43210, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clae.2009.04.003DOI Listing
August 2009

Validation of optical coherence tomography-based crystalline lens thickness measurements in children.

Optom Vis Sci 2009 Mar;86(3):181-7

The Ohio State University, College of Optometry, Columbus, Ohio 43210-1240, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0b013e318198198dDOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2814774PMC
March 2009

Higher-order aberrations when wearing sphere and toric soft contact lenses.

Optom Vis Sci 2009 Feb;86(2):115-22

The Ohio State University, College of Optometry, Columbus, Ohio 43210, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0b013e318194e951DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2765793PMC
February 2009

Validation of aberrometry-based relative peripheral refraction measurements.

Ophthalmic Physiol Opt 2008 Jan;28(1):83-90

College of Optometry, The Ohio State University, 338 West 10th Ave., Columbus, OH 43210, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1475-1313.2007.00535.xDOI Listing
January 2008

Benefits of contact lens wear for children and teens.

Eye Contact Lens 2007 Nov;33(6 Pt 1):317-21

The Ohio State University College of Optometry, 338 West 10th Avenue, Columbus, OH 43210, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICL.0b013e31804f80fbDOI Listing
November 2007

Visual acuity with spherical and toric soft contact lenses in low- to moderate-astigmatic eyes.

Optom Vis Sci 2007 Oct;84(10):969-75

The Ohio State University College of Optometry, Columbus 43210, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0b013e318157c6dcDOI Listing
October 2007

Contact Lenses in Pediatrics (CLIP) Study: chair time and ocular health.

Optom Vis Sci 2007 Sep;84(9):896-902

The Ohio State University College of Optometry; Columbus, Ohio 43210-1240, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0b013e3181559c3cDOI Listing
September 2007

Reliability of grading lissamine green conjunctival staining.

Cornea 2006 Jul;25(6):695-700

Ohio State University College of Optometry, Columbus, OH 43210, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.ico.0000208814.94495.a6DOI Listing
July 2006

The effect of overnight contact lens corneal reshaping on higher-order aberrations and best-corrected visual acuity.

Optom Vis Sci 2005 Jun;82(6):490-7

The Ohio State University College of Optometry, Columbus, Ohio 43210, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.opx.0000168586.36165.bbDOI Listing
June 2005

An assessment of grading scales for meibography images.

Cornea 2005 May;24(4):382-8

The Ohio State University, Columbus, 43218, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.ico.0000148291.38076.59DOI Listing
May 2005

The assessment of automated measures of hydrogel contact lens refractive index.

Ophthalmic Physiol Opt 2003 Nov;23(6):517-25

College of Optometry, The Ohio State University, 320 West 10th Avenue, PO Box 182342, Columbus, OH 43218-2342, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1475-1313.2003.00147.xDOI Listing
November 2003