Bosniak classification of cystic renal masses version 2019 does not increase the interobserver agreement or the proportion of masses categorized into lower Bosniak classes for non-subspecialized readers on CT or MR.

Eur J Radiol 2020 Oct 15;131:109270. Epub 2020 Sep 15.

Hospital Sao Paulo, Universidade Federal de Sao Paulo (UNIFESP) - R. Botucatu, 740 - Vila Clementino, São Paulo, SP, 04023-062, Brazil; Grupo Fleury - R. Cincinato Braga, 282 - Bela Vista, São Paulo, SP, 01333-910 Brazil.

Purpose: In a condition so prevalent as renal cysts, classifications should display satisfactory reproducibility not only among subspecialized readers. We aimed to compare the interobserver agreement of the Bosniak classification version 2019 (BC19) and current Bosniak classification (CBC) for non-subspecialized readers on CT and MRI and to verify whether BC19 leads to a downgrade of renal cystic masses when compared to CBC.

Methods: We evaluated 50 renal cystic masses in 47 patients on MR and CT (25 per method). Eighteen readers (nine third-year radiology residents and nine abdominal imaging fellows) assessed the images using BC19 and CBC with an eight-week interval. Kappa statistic was used to assess agreement. An average score of Bosniak categories across all raters evaluated if there was downgrading of lesions on BC19.

Results: The highest values of Kappa were found for fellows on CBC-MR (κ = 0.51), and the lowest values were found for residents on CBC-MR and fellows on BC19-MR (both κ = 0.36). On CBC, interobserver agreement was moderate for MR and CT (κ = 0.42 and 0.43, respectively), whereas on BC19, it was fair (κ = 0.38 and 0.40, respectively). The best agreements were in categories I (κ = 0.49-0.69) and IV (κ = 0.45-0.51). The poorest agreements occurred at IIF (κ = 0.18 on BC19-CT). There was a moderate median increase from CBC to BC19 in terms of Bosniak categories for both methods (MR [Z=-2.058, p = 0.040] and CT [Z=-2.509, p = 0.012]).

Conclusion: BC19, when compared to CBC, did not improve interobserver agreement nor diminished the proportion of masses categorized into lower Bosniak classes among non-subspecialized readers.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2020.109270DOI Listing
October 2020

Is liver perfusion CT reproducible? A study on intra- and interobserver agreement of normal hepatic haemodynamic parameters obtained with two different software packages.

Br J Radiol 2017 Oct 22;90(1078):20170214. Epub 2017 Aug 22.

1 Department of Imaging, Universidade Federal de São Paulo, São Paulo, Brazil.

Objective: To evaluate the agreement between the measurements of perfusion CT parameters in normal livers by using two different software packages.

Methods: This retrospective study was based on 78 liver perfusion CT examinations acquired for detecting suspected liver metastasis. Patients with any morphological or functional hepatic abnormalities were excluded. The final analysis included 37 patients (59.7 ± 14.9 y). Two readers (1 and 2) independently measured perfusion parameters using different software packages from two major manufacturers (A and B). Arterial perfusion (AP) and portal perfusion (PP) were determined using the dual-input vascular one-compartmental model. Inter-reader agreement for each package and intrareader agreement between both packages were assessed with intraclass correlation coefficients (ICC) and Bland-Altman statistics.

Results: Inter-reader agreement was substantial for AP using software A (ICC = 0.82) and B (ICC = 0.85-0.86), fair for PP using software A (ICC = 0.44) and fair to moderate for PP using software B (ICC = 0.56-0.77). Intrareader agreement between software A and B ranged from slight to moderate (ICC = 0.32-0.62) for readers 1 and 2 considering the AP parameters, and from fair to moderate (ICC = 0.40-0.69) for readers 1 and 2 considering the PP parameters.

Conclusion: At best there was only moderate agreement between both software packages, resulting in some uncertainty and suboptimal reproducibility. Advances in knowledge: Software-dependent factors may contribute to variance in perfusion measurements, demanding further technical improvements. AP measurements seem to be the most reproducible parameter to be adopted when evaluating liver perfusion CT.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1259/bjr.20170214DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5853353PMC
October 2017

Readjustment of abdominal computed tomography protocols in a university hospital: impact on radiation dose.

Radiol Bras 2015 Sep-Oct;48(5):292-7

Private Docent, Associate Professor, Department of Imaging Diagnosis at Escola Paulista de Medicina - Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil.

Objective: To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters.

Materials And Methods: Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A - 551 studies) and three months after (group B - 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDIvol per phase, mean DLP per phase, and mean DLP per scan.

Results: A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDIvol per phase, DLP per phase and DLP per scan (p < 0.001).

Conclusion: The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1590/0100-3984.2014.0054DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4633073PMC
November 2015

Comparison between ultrasound and noncontrast helical computed tomography for identification of acute ureterolithiasis in a teaching hospital setting.

Sao Paulo Med J 2007 Mar;125(2):102-7

Diagnostic Imaging Department, Universidade Federal de São Paulo - Escola Paulista de Medicina, São Paulo, Brazil.

Context And Objective: Recent studies have shown noncontrast computed tomography (NCT) to be more effective than ultrasound (US) for imaging acute ureterolithiasis. However, to our knowledge, there are few studies directly comparing these techniques in an emergency teaching hospital setting. The objectives of this study were to compare the diagnostic accuracy of US and NCT performed by senior radiology residents for diagnosing acute ureterolithiasis; and to assess interobserver agreement on tomography interpretations by residents and experienced abdominal radiologists.

Design And Setting: Prospective study of 52 consecutive patients, who underwent both US and NCT within an interval of eight hours, at Hospital São Paulo.

Methods: US scans were performed by senior residents and read by experienced radiologists. NCT scan images were read by senior residents, and subsequently by three abdominal radiologists. The interobserver variability was assessed using the kappa statistic.

Results: Ureteral calculi were found in 40 out of 52 patients (77%). US presented sensitivity of 22% and specificity of 100%. When collecting system dilatation was associated, US demonstrated 73% sensitivity, 82% specificity. The interobserver agreement in NCT analysis was very high with regard to identification of calculi, collecting system dilatation and stranding of perinephric fat.

Conclusions: US has limited value for identifying ureteral calculi in comparison with NCT, even when collecting system dilatation is present. Residents and abdominal radiologists demonstrated excellent agreement rates for ureteral calculi, identification of collecting system dilatation and stranding of perinephric fat on NCT.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1590/s1516-31802007000200007DOI Listing
March 2007
-->