Daniel A Herzka

Daniel A Herzka

UNVERIFIED PROFILE

Are you Daniel A Herzka?   Register this Author

Register author
Daniel A Herzka

Daniel A Herzka

Publications by authors named "Daniel A Herzka"

Are you Daniel A Herzka?   Register this Author

56Publications

583Reads

42Profile Views

Sorted Golden-step phase encoding: an improved Golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imaging.

J Cardiovasc Magn Reson 2019 Apr 18;21(1):23. Epub 2019 Apr 18.

Department of Biomedical Engineering, Johns Hopkins University School of Medicine, 720 Rutland Ave, Suite 726 Ross Building, Baltimore, MD, 21205, USA.

View Article

Download full-text PDF

Source
https://jcmr-online.biomedcentral.com/articles/10.1186/s1296
Publisher Site
http://dx.doi.org/10.1186/s12968-019-0533-8DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6472023PMC
April 2019

A cardiovascular magnetic resonance (CMR) safe metal braided catheter design for interventional CMR at 1.5 T: freedom from radiofrequency induced heating and preserved mechanical performance.

J Cardiovasc Magn Reson 2019 Mar 7;21(1):16. Epub 2019 Mar 7.

Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2c713, Bethesda, MD, 20892-1538, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1186/s12968-019-0526-7DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6404324PMC
March 2019

A three-dimensional free-breathing sequence for simultaneous myocardial T and T mapping.

Magn Reson Med 2019 02 4;81(2):1031-1043. Epub 2018 Nov 4.

Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.

View Article

Download full-text PDF

Source
http://doi.wiley.com/10.1002/mrm.27466
Publisher Site
http://dx.doi.org/10.1002/mrm.27466DOI Listing
February 2019

Ablation Lesion Characterization in Scarred Substrate Assessed Using Cardiac Magnetic Resonance.

JACC Clin Electrophysiol 2019 Jan 26;5(1):91-100. Epub 2018 Dec 26.

Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland; Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland; Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacep.2018.11.001DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6355250PMC
January 2019

Transcatheter pledget-assisted suture tricuspid annuloplasty (PASTA) to create a double-orifice valve.

Catheter Cardiovasc Interv 2018 Sep 6;92(3):E175-E184. Epub 2018 Feb 6.

Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.27531DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6078835PMC
September 2018

Blood volume measurement using cardiovascular magnetic resonance and ferumoxytol: preclinical validation.

J Cardiovasc Magn Reson 2018 09 10;20(1):62. Epub 2018 Sep 10.

Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Building 10, Room 2C713, 10 Center Drive, Bethesda, MD, 20892, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1186/s12968-018-0486-3DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6131893PMC
September 2018

Three-dimensional free breathing whole heart cardiovascular magnetic resonance T mapping at 3 T.

J Cardiovasc Magn Reson 2018 09 17;20(1):64. Epub 2018 Sep 17.

Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.

View Article

Download full-text PDF

Source
https://jcmr-online.biomedcentral.com/articles/10.1186/s1296
Publisher Site
http://dx.doi.org/10.1186/s12968-018-0487-2DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6139904PMC
September 2018

Right heart catheterization using metallic guidewires and low SAR cardiovascular magnetic resonance fluoroscopy at 1.5 Tesla: first in human experience.

J Cardiovasc Magn Reson 2018 06 21;20(1):41. Epub 2018 Jun 21.

Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Building 10, Room 2C713, Bethesda, MD, 20892-1538, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1186/s12968-018-0458-7DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6011242PMC
June 2018

Non-contrast-enhanced T -weighted MRI of myocardial radiofrequency ablation lesions.

Magn Reson Med 2018 02 11;79(2):879-889. Epub 2017 May 11.

Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.26750DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5681891PMC
February 2018

MR-guided percutaneous sclerotherapy of low-flow vascular malformations: Clinical experience using a 1.5 tesla MR system.

J Magn Reson Imaging 2017 04 31;45(4):1154-1162. Epub 2016 Oct 31.

Vascular and Interventional Radiology, Department of Radiology, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.25502DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5352530PMC
April 2017

Real-time free-breathing cardiac imaging with self-calibrated through-time radial GRAPPA.

Magn Reson Med 2017 01 10;77(1):250-264. Epub 2016 Mar 10.

Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.26112DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5920649PMC
January 2017

High Resolution Three-Dimensional MR Imaging of the Skull Base: Compartments, Boundaries, and Critical Structures.

Radiol Clin North Am 2017 Jan;55(1):17-30

Department of Neurosurgery, Johns Hopkins Hospital, 600 North Wolfe Street, Baltimore, MD 21287, USA. Electronic address:

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rcl.2016.08.011DOI Listing
January 2017

A Novel Experimental Animal Model of Adult Chronic Hydrocephalus.

Neurosurgery 2016 Nov;79(5):746-756

*Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, Maryland; ‡Department of Psychiatry and Behavioral Sciences, School of Medicine, Johns Hopkins University, Baltimore, Maryland; §F. M. Kirby Research Center for Functional Brain Imaging at the Kennedy Krieger Institute, School of Medicine, Johns Hopkins University, Baltimore, Maryland; ¶Department of Radiology and Radiological Science, School of Medicine, Johns Hopkins University, Baltimore, Maryland; ‖Department of Biomedical Engeniering, Johns Hopkins University, Baltimore, Maryland; #Department of Pathology, Division of Neurophatology, School of Medicine, Johns Hopkins University, Baltimore, Maryland; **Department of Oncology, School of Medicine, Johns Hopkins University, Baltimore, Maryland; ‡‡Laboratory of Neuroscience, Facultad de Psicologia, University of Colima, Colima, Mexico; §§Department of Neurosurgery, School of Medicine in St. Louis, Washington University, St. Louis, Missouri; ¶¶Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, Maryland; ‖‖Department of Oncology, School of Medicine, Johns Hopkins University, Baltimore, Maryland.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1227/NEU.0000000000001405DOI Listing
November 2016

Realistic analytical polyhedral MRI phantoms.

Magn Reson Med 2016 08 19;76(2):663-78. Epub 2015 Oct 19.

Department of Biomedical Engineering, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.

View Article

Download full-text PDF

Source
http://doi.wiley.com/10.1002/mrm.25888
Publisher Site
http://dx.doi.org/10.1002/mrm.25888DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4837112PMC
August 2016

Pseudo-projection-driven, self-gated cardiac cine imaging using cartesian golden step phase encoding.

Magn Reson Med 2016 08 31;76(2):417-29. Epub 2015 Oct 31.

Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.25834DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5019250PMC
August 2016

Improvement in B1+ Homogeneity and Average Flip Angle Using Dual-Source Parallel RF Excitation for Cardiac MRI in Swine Hearts.

PLoS One 2015 5;10(10):e0139859. Epub 2015 Oct 5.

Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, United States of America.

View Article

Download full-text PDF

Source
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0139859PLOS
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4593605PMC
June 2016

Invited Commentary: The Rise of Microradiology.

Radiographics 2015 Jul-Aug;35(4):1091-3

Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University Baltimore, Maryland.

View Article

Download full-text PDF

Source
http://pubs.rsna.org/doi/10.1148/rg.2015140311
Publisher Site
http://dx.doi.org/10.1148/rg.2015140311DOI Listing
April 2016

Myofiber Architecture of the Human Atria as Revealed by Submillimeter Diffusion Tensor Imaging.

Circ Arrhythm Electrophysiol 2016 Apr;9(4):e004133

From the Departments of Biomedical Engineering (F.P., D.A.H., N.A.T., E.R.M.), Medicine (H.A.), and Radiology (S.M., E.R.M), Johns Hopkins University, Baltimore, MD; Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, MD (N.G, D.A.B.); and Departments of Bioengineering, Medicine, and Radiology, University of California, San Diego (E.R.M.).

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCEP.116.004133DOI Listing
April 2016

Three-dimensional whole-heart T2 mapping at 3T.

Magn Reson Med 2015 Sep 19;74(3):803-16. Epub 2014 Sep 19.

Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.25458DOI Listing
September 2015

Image-based reconstruction of three-dimensional myocardial infarct geometry for patient-specific modeling of cardiac electrophysiology.

Med Phys 2015 Aug;42(8):4579-90

Institute for Computational Medicine, Johns Hopkins University, Baltimore, Maryland 21205 and Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.4926428DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4499050PMC
August 2015

MR-guided sclerotherapy of low-flow vascular malformations using T2 -weighted interrupted bSSFP (T2 W-iSSFP): comparison of pulse sequences for visualization and needle guidance.

J Magn Reson Imaging 2015 Feb 6;41(2):525-35. Epub 2014 Jan 6.

Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.24552DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5241156PMC
February 2015

Image-based Reconstruction of 3D Myocardial Infarct Geometry for Patient Specific Applications.

Proc SPIE Int Soc Opt Eng 2015 Feb 20;9413. Epub 2015 Mar 20.

Institute for Computational Medicine, Johns Hopkins University, Baltimore, MD, United States ; Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, United States.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1117/12.2082113DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4664077PMC
February 2015

Fat-suppression techniques for 3-T MR imaging of the musculoskeletal system.

Radiographics 2014 Jan-Feb;34(1):217-33

From the Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Hospital, Baltimore, Md (F.D.G., M.R.A., J.A.C.); Division of Radiological Physics, Department of Radiology, Clinic of Radiology and Nuclear Medicine, University of Basel Hospital, Basel, Switzerland (F.S.); Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Md (D.A.H.); Department of Radiology, University of Florida College of Medicine, Gainesville, Fla (C.W.D.); and Departments of Radiology, Bioengineering, and Orthopaedic Surgery, Stanford University School of Medicine, Stanford, Calif (G.E.G.). Recipient of a Certificate of Merit award for an education exhibit at the 2012 RSNA Annual Meeting.

View Article

Download full-text PDF

Source
http://pubs.rsna.org/doi/10.1148/rg.341135130
Publisher Site
http://dx.doi.org/10.1148/rg.341135130DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4359893PMC
January 2015

Sildenafil does not improve cardiomyopathy in Duchenne/Becker muscular dystrophy.

Ann Neurol 2014 Oct 10;76(4):541-9. Epub 2014 Jul 10.

Hugo W. Moser Research Institute, Kennedy Krieger Institute, Baltimore, MD; Departments of Neurology, Johns Hopkins University School of Medicine, Baltimore, MD.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/ana.24214DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4191982PMC
October 2014

Real-time imaging with radial GRAPPA: Implementation on a heterogeneous architecture for low-latency reconstructions.

Magn Reson Imaging 2014 Jul 15;32(6):747-58. Epub 2014 Mar 15.

Case Western Reserve University, Department of Radiology, Cleveland, OH.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mri.2014.02.022DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4035436PMC
July 2014

Adiabatic inversion pulses for myocardial T1 mapping.

Magn Reson Med 2014 Apr 30;71(4):1428-34. Epub 2013 May 30.

National Institutes of Health, Department of Health and Human Services, National Heart, Lung and Blood Institute, Bethesda, Maryland, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.24793DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3775900PMC
April 2014

Quantitative Assessment of Single-Image Super-Resolution in Myocardial Scar Imaging.

IEEE J Transl Eng Health Med 2014;2

Division of Cardiology, The Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA ; Department of Biomedical Engineering, The Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA ; The Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University School of Medicine, Baltimore, MD.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1109/JTEHM.2014.2303806DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4331080PMC
January 2014

Regional cardiac function assessment in 4D CT: comparison between SQUEEZ and ejection fraction.

Conf Proc IEEE Eng Med Biol Soc 2012 ;2012:4966-9

Johns Hopkins University School of Medicine, Baltimore, MD 21205 USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2012.6347107DOI Listing
August 2013

Influence of Off-resonance in myocardial T1-mapping using SSFP based MOLLI method.

J Cardiovasc Magn Reson 2013 Jul 22;15:63. Epub 2013 Jul 22.

National Heart, Lung, and Blood Institute, National Institutes of Health, DHHS, Bethesda, MD 20892, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1186/1532-429X-15-63DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3733653PMC
July 2013

Human cartilage repair with a photoreactive adhesive-hydrogel composite.

Sci Transl Med 2013 Jan;5(167):167ra6

Translational Tissue Engineering Center, Wilmer Eye Institute and the Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1126/scitranslmed.3004838DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3972413PMC
January 2013

A new method for cardiac computed tomography regional function assessment: stretch quantifier for endocardial engraved zones (SQUEEZ).

Circ Cardiovasc Imaging 2012 Mar 16;5(2):243-50. Epub 2012 Feb 16.

Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD, USA.

View Article

Download full-text PDF

Source
http://circimaging.ahajournals.org/content/early/2012/02/16/
Web Search
http://circimaging.ahajournals.org/cgi/doi/10.1161/CIRCIMAGI
Publisher Site
http://dx.doi.org/10.1161/CIRCIMAGING.111.970061DOI Listing
March 2012

2D/3D registration for X-ray guided bronchoscopy using distance map classification.

Conf Proc IEEE Eng Med Biol Soc 2010 ;2010:3715-8

Dept. of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, MD 21205, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2010.5627657DOI Listing
April 2011

Assessing the accuracy and precision of musculoskeletal motion tracking using cine-PC MRI on a 3.0T platform.

J Biomech 2011 Jan 21;44(1):193-7. Epub 2010 Sep 21.

Rehabilitation Medicine Department, National Institutes of Health, Building 10 CRC RM 1-1469, 10 Center Drive MSC 1604, Bethesda, MD 20892-1604, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2010.08.029DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3236440PMC
January 2011

Efficient implementation of hardware-optimized gradient sequences for real-time imaging.

Magn Reson Med 2010 Dec;64(6):1814-20

Translational Medicine Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, DHHS, Bethesda, Maryland 20892-1061, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.22211DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3399692PMC
December 2010

Cardiovascular magnetic resonance T2 signal abnormalities in left ventricular ballooning syndrome.

Int J Cardiovasc Imaging 2010 Feb 28;26(2):227-32. Epub 2009 Oct 28.

Section of Cardiology, Department of Medicine, Washington Hospital Center, Washington, DC, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10554-009-9515-5DOI Listing
February 2010

Profile order and time-dependent artifacts in contrast-enhanced coronary MR angiography at 3T: origin and prevention.

Magn Reson Med 2009 Aug;62(2):292-9

National Heart, Lung, and Blood Institute (NHLBI), National Institutes of Health (NIH), Bethesda, Maryland 20892-2281, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.21997DOI Listing
August 2009

Coronary artery anomalies and variants: technical feasibility of assessment with coronary MR angiography at 3 T.

Radiology 2008 Apr;247(1):220-7

Department of Diagnostic Radiology, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2471070274DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4623933PMC
April 2008

Coronary magnetic resonance vein imaging: imaging contrast, sequence, and timing.

Magn Reson Med 2007 Dec;58(6):1196-206

Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center, Boston, Massachusetts 02215, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.21395DOI Listing
December 2007

Coronary MR angiography at 3T during diastole and systole.

J Magn Reson Imaging 2007 Oct;26(4):921-6

National Heart, Lung, and Blood Institute (NHLBI), National Institutes of Health (NIH), Bethesda, Maryland, USA.

View Article

Download full-text PDF

Source
https://afni.nimh.nih.gov/sscc/staff/rwcox/ISMRM_2006/ISMRM%
Web Search
http://doi.wiley.com/10.1002/jmri.21056
Publisher Site
http://dx.doi.org/10.1002/jmri.21056DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4966157PMC
October 2007

Should all patients with suspected coronary artery disease undergo coronary angiography with 16-row MDCT?

Nat Clin Pract Cardiovasc Med 2007 Feb;4(2):74-5

Clinical Sites Research Program, Philips Research North America, Briarcliff Manor, NY, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1038/ncpcardio0777DOI Listing
February 2007

Single heartbeat cardiac tagging for the evaluation of transient phenomena.

Magn Reson Med 2005 Dec;54(6):1455-64

Department of Biomedical Engineering, Johns Hopkins University School of Medicine Baltimore, Maryland 20892-1061, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.20719DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2034344PMC
December 2005

Signal-to-noise ratio behavior of steady-state free precession.

Magn Reson Med 2004 Jul;52(1):123-30

Department of Radiology, Stanford University Medical Center, Stanford, California 94304, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.20126DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2396310PMC
July 2004

Myocardial tagging with SSFP.

Magn Reson Med 2003 Feb;49(2):329-40

Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.10361DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2041894PMC
February 2003

Phased array ghost elimination (PAGE) for segmented SSFP imaging with interrupted steady-state.

Magn Reson Med 2002 Dec;48(6):1076-80

Laboratory of Cardiac Energetics, National Institutes of Health, National Heart, Lung and Blood Institute, Bethesda, Maryland 20892-1061, USA.

View Article

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.10309DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2396315PMC
December 2002

Multishot EPI-SSFP in the heart.

Magn Reson Med 2002 Apr;47(4):655-64

Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland 20892-1061, USA.

View Article

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2396260PMC
April 2002