Publications by authors named "Ariana Tudoroniu"

5 Publications

  • Page 1 of 1

GCC Consolidated Feedback to ICH on the 2019 ICH M10 Bioanalytical Method Validation Draft Guideline.

Bioanalysis 2019 Sep 30;11(18s):1-228. Epub 2019 Sep 30.

WuXi Apptec, Shanghai, China.

The 13 GCC Closed Forum for Bioanalysis was held in New Orleans, Louisiana, USA on April 5, 2019. This GCC meeting was organized to discuss the contents of the 2019 ICH M10 Bioanalytical Method Validation Draft Guideline published in February 2019 and consolidate the feedback of the GCC members. In attendance were 63 senior-level participants from eight countries representing 44 bioanalytical CRO companies/sites. This event represented a unique opportunity for CRO bioanalytical experts to share their opinions and concerns regarding the ICH M10 Bioanalytical Method Validation Draft Guideline and to build unified comments to be provided to the ICH.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.4155/bio-2019-0207DOI Listing
September 2019

11th GCC Closed Forum: cumulative stability; matrix stability; immunogenicity assays; laboratory manuals; biosimilars; chiral methods; hybrid LBA/LCMS assays; fit-for-purpose validation; China Food and Drug Administration bioanalytical method validation.

Bioanalysis 2018 Apr 27;10(7):433-444. Epub 2018 Apr 27.

Worldwide Clinical Trials, Austin, TX, USA.

The 11th Global CRO Council Closed Forum was held in Universal City, CA, USA on 3 April 2017. Representatives from international CRO members offering bioanalytical services were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The second CRO-Pharma Scientific Interchange Meeting was held on 7 April 2017, which included Pharma representatives' sharing perspectives on the topics discussed earlier in the week with the CRO members. The issues discussed at the meetings included cumulative stability evaluations, matrix stability evaluations, the 2016 US FDA Immunogenicity Guidance and recent and unexpected FDA Form 483s on immunogenicity assays, the bioanalytical laboratory's role in writing PK sample collection instructions, biosimilars, CRO perspectives on the use of chiral versus achiral methods, hybrid LBA/LCMS assays, applications of fit-for-purpose validation and, at the Global CRO Council Closed Forum only, the status and trend of current regulated bioanalytical practice in China under CFDA's new BMV policy. Conclusions from discussions of these topics at both meetings are included in this report.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.4155/bio-2018-0014DOI Listing
April 2018

Development of a sensitive method for simultaneous determination of fluticasone propionate and salmeterol in plasma samples by liquid chromatography-tandem mass spectrometry.

Biomed Chromatogr 2012 May;26(5):627-35

3S-Pharmacological Consultation and Research GmbH, Koenigsbergerstrasse 1, 27243 Harpstedt, Germany.

A new method for the fast simultaneous quantification of fluticasone propionate and salmeterol from plasma samples by liquid chromatography-tandem mass spectrometry, with adequate sensitivity for pharmacokinetic applications, was developed and validated. The chromatographic separation and mass-spectrometric parameters were optimized for the retention and detection of the two compounds, despite quite different structures and properties. Two columns connected in series were used, cation-exchange (Zorbax 300-SCX, 5 cm x 2.1 mm, 5 μm) and octadecyl (Discovery HSC₁₈, 10 cm x 2.1 mm, 5 μm). The mass-spectrometric interface was operated in negative electrospray ionization mode; high sensitivity and lesser matrix effects were obtained, permitting smaller consumption of plasma. The sample preparation was based on supported liquid-liquid extraction in 96-well format plates that provided clean samples with a simplified procedure that was suitable for automation. The method was validated according to regulatory guidelines, by assessing lower limits of quantification, selectivity, linearity, accuracy, precision, extraction recoveries and matrix effects. A comparison with two other methods for the separate determination of fluticasone propionate and salmeterol in plasma samples, previously developed by our group, is presented. The statistical evaluation of the results obtained with the three methods on a set of unknown samples from treated patients demonstrated good correlation (R² 0.987 for fluticasone propionate and 0.967 for salmeterol).
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.1708DOI Listing
May 2012

Development and validation of an HPLC-MS/MS method to quantify clopidogrel acyl glucuronide, clopidogrel acid metabolite, and clopidogrel in plasma samples avoiding analyte back-conversion.

Anal Bioanal Chem 2011 Aug 9;401(3):1023-34. Epub 2011 Jun 9.

3S-Pharmacological Consultation & Research GmbH, Koenigsbergerstrasse 1, 27243 Harpstedt, Germany.

A new sensitive and fast quantitative analytical method for the simultaneous determination of clopidogrel, its main metabolite clopidogrel carboxylic acid, and the newly described acyl glucuronide metabolite, in human plasma samples, is presented. The analytical procedures (plasma storage, handling, and extract storage in the autosampler) were optimized in order to avoid back-conversion; a known drawback in measurements of clopidogrel. Clopidogrel acyl glucuronide was confirmed as a major source of back-conversion to the parent drug in the presence of methanol, and thorough stability experiments were carried out to find the most appropriate conditions for an accurate analysis of clopidogrel and the two metabolites. The method was validated by assessing selectivity, sensitivity, linearity, accuracy, and precision for all three analytes, in accordance to Food and Drug Administration guidelines. Spiked quality controls in plasma as well as incurred samples were used to verify back-conversion in the selected conditions, with results meeting European Medicines Agency acceptance criteria (concentrations within 80-120% of the first reading). The method was then applied to a pharmacokinetic study, and for the first time, a pharmacokinetic curve of clopidogrel acyl glucuronide in human plasma is presented. The concentrations ranged up to 1,048.684 ng/mL, with a mean of 470.268 ng/mL, while clopidogrel had a mean C(max) of 1.348 ng/mL; these orders of magnitude show how much the back-conversion of this metabolite may influence clopidogrel quantification if it is not properly controlled.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-011-5147-4DOI Listing
August 2011

High-throughput HPLC-MS/MS method to determine ibandronate in human plasma for pharmacokinetic applications.

J Chromatogr B Analyt Technol Biomed Life Sci 2009 Oct 12;877(27):3159-68. Epub 2009 Aug 12.

Pharma Serv Int'l SRL, 52 Sabinelor Str., 5th District, 050853 Bucharest, Romania.

A sensitive high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of ibandronate in human plasma. In a previous study, we have analyzed alendronate in urine samples of subjects treated at therapeutic dosages, using a derivatization approach; a similar derivatization was adapted and improved to determine ibandronate in plasma. The bisphosphonate was isolated from the biological matrix by liquid-liquid extraction, and derivatized with trimethylsilyldiazomethane prior to separation on a reversed-phase column (Supelco Discovery HSC18) and detection on a quadrupole-linear ion trap mass spectrometer (API 4000 QTrap). Various parameters of extraction and derivatization were optimized in order to get adequate recovery, high derivatization yield and minimal ion suppression; a deuterated analogue, d3-ibandronate, was used as internal standard. The transitions 376.1-->114.2 and 379.1-->61.0 were acquired to monitor ibandronate and d3-ibandronate derivatives, respectively. A multiplexing LC system made possible the overlapping of two chromatographic runs, thus the interval between injections being reduced to only 2min, a very short analysis time for compounds of this class. The method was fully validated over the quantification range 0.2-175.0ng/ml, allowing an appropriate evaluation of the plasma concentrations of ibandronate, expected at therapeutic dosage, as proved by application to a pharmacokinetic study. A good linearity over the selected range (r>0.99), accuracy and precision within +/-15% of the target values and a recovery over 50% were obtained.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2009.08.007DOI Listing
October 2009