Frequency-doubled femtosecond Er-doped fiber laser for two-photon excited fluorescence imaging.

Biomed Opt Express 2020 Aug 20;11(8):4431-4442. Epub 2020 Jul 20.

Laser & Fiber Electronics Group, Faculty of Electronics, Wrocław University of Science and Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland.

A femtosecond frequency-doubled erbium-doped fiber laser with an adjustable pulse repetition rate is developed and applied in two-photon excited fluorescence microscopy. The all-fiber laser system provides the fundamental pulse at 1560 nm wavelength with 22 fs duration for the second harmonic generation, resulting in 1.35 nJ, 60 fs pulses at 780 nm. The repetition rate is adjusted by a pulse picker unit built-in within the amplifier chain, directly providing transform-limited pulses for any chosen repetition rate between 1 and 12 MHz. We employed the laser source to drive a scanning two-photon excited fluorescence microscope for rat skin and other samples' imaging at various pulse repetition rates. Due to compactness, ease of operation, and suitable pulse characteristics, the laser source can be considered as an attractive alternative for Ti:Sapphire laser in biomedical imaging.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/BOE.396878DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7449741PMC
August 2020

Stabilized all-fiber source for generation of tunable broadband fCEO-free mid-IR frequency comb in the 7 - 9 µm range.

Opt Express 2019 Dec;27(26):37435-37445

A compact and robust all-fiber difference frequency generation-based source of broadband mid-infrared radiation is presented. The source emits tunable radiation in the range between 6.5 µm and 9 µm with an average output power up to 5 mW at 125 MHz repetition frequency. The all-in-fiber construction of the source along with active stabilization techniques results in long-term repetition rate stability of 3 Hz per 10 h and a standard deviation of the output power better than 0.8% per 1 h. The applicability of the presented source to laser spectroscopy is demonstrated by measuring the absorption spectrum of nitrous oxide (NO) around 7.8 µm. The robustness and good long- and short-term stability of the source opens up for applications outside the laboratory.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.27.037435DOI Listing
December 2019

Microtubule end tethering of a processive kinesin-8 motor Kif18b is required for spindle positioning.

J Cell Biol 2018 07 16;217(7):2403-2416. Epub 2018 Apr 16.

Wellcome Trust Centre for Cell Biology, School of Biological Sciences, University of Edinburgh, Edinburgh, Scotland, UK

Mitotic spindle positioning specifies the plane of cell division during anaphase. Spindle orientation and positioning are therefore critical to ensure symmetric division in mitosis and asymmetric division during development. The control of astral microtubule length plays an essential role in positioning the spindle. In this study, using gene knockout, we show that the kinesin-8 Kif18b controls microtubule length to center the mitotic spindle at metaphase. Using in vitro reconstitution, we reveal that Kif18b is a highly processive plus end-directed motor that uses a C-terminal nonmotor microtubule-binding region to accumulate at growing microtubule plus ends. This region is regulated by phosphorylation to spatially control Kif18b accumulation at plus ends and is essential for Kif18b-dependent spindle positioning and regulation of microtubule length. Finally, we demonstrate that Kif18b shortens microtubules by increasing the catastrophe rate of dynamic microtubules. Overall, our work reveals that Kif18b uses its motile properties to reach microtubule ends, where it regulates astral microtubule length to ensure spindle centering.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1083/jcb.201705209DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6028548PMC
July 2018

Mid-Infrared Trace Gas Sensor Technology Based on Intracavity Quartz-Enhanced Photoacoustic Spectroscopy.

Sensors (Basel) 2017 Mar 4;17(3). Epub 2017 Mar 4.

Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005-1892, USA.

The application of compact inexpensive trace gas sensor technology to a mid-infrared nitric oxide (NO) detectoion using intracavity quartz-enhanced photoacoustic spectroscopy (I-QEPAS) is reported. A minimum detection limit of 4.8 ppbv within a 30 ms integration time was demonstrated by using a room-temperature, continuous-wave, distributed-feedback quantum cascade laser (QCL) emitting at 5.263 µm (1900.08 cm) and a new compact design of a high-finesse bow-tie optical cavity with an integrated resonant quartz tuning fork (QTF). The optimum configuration of the bow-tie cavity was simulated using custom software. Measurements were performed with a wavelength modulation scheme (WM) using a detection procedure.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.3390/s17030513DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5375799PMC
March 2017

Mid-infrared dual-gas sensor for simultaneous detection of methane and ethane using a single continuous-wave interband cascade laser.

Opt Express 2016 Jul;24(15):16973-85

A continuous-wave (CW) interband cascade laser (ICL) based mid-infrared sensor system was demonstrated for simultaneous detection of atmospheric methane (CH4) and ethane (C2H6). A 3.337 µm CW ICL with an emitting wavenumber range of 2996.0-3001.5 cm-1 was used to simultaneously target two absorption lines, C2H6 at 2996.88 cm-1 and CH4 at 2999.06 cm-1, respectively. The sensor performance was first evaluated for single-gas detection by only targeting the absorption line of one gas species. Allan deviations of 11.2 parts per billion in volume (ppbv) for CH4 and 1.86 ppbv for C2H6 with an averaging time of 3.4 s were achieved for the detection of these two gases. Dual-gas detection was realized by using a long-term scan signal to target both CH4 and C2H6 lines. The Allan deviations increased slightly to 17.4 ppbv for CH4 and 2.4 ppbv for C2H6 with an averaging time of 4.6 s due to laser temperature and power drift caused by long-term wavelength scanning. Measurements for both indoor and outdoor concentration changes of CH4 and C2H6 were conducted. The reported single ICL based dual-gas sensor system has the advantages of reduced size and cost compared to two separate sensor systems.
View Article and Find Full Text PDF

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.24.016973DOI Listing
July 2016